NEPTUNE is a freight ship. The Coast Guard has recorded 8 inspections since 2016, most recently in April 2018, along with 16 deficiencies and 1 operational control.
Records from 2016 to 2018. Most recent: inspection, 20 April 2018.
This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it20867 - Convention (Subpart B), Gross Ton 32394 - Dead Weight, Metric Ton 41748 - Displacement, Metric Ton 11821 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 8
20 April 2018Deficiency Check · Administrative Inspection
0610-Cargo ships may carry one or more free-fall lifeboats complying with the requirements of section 4.7 of the code. PSCO found free-fall lifeboat door rubber seal to be severly degraded-74SOLAS(14)III/31.1.2.1
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2018
Resolved 20 April 2018
Resolution: SEC HOU-GAL PSC Branch received a class report satisfying the requirements
2490-Except as provided to paragraph 6.2 of this regulation...each incinerator subject to this paragraph shall be approved by the adminstration taking into account the standard specifications for shipboard incinerators developed by the organization. PSCO found refractory and brick damage to inside of the incinerator-MARPOL(73/78)VI/16.6.1
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 20 April 2018
Resolution: SEC HOU-GAL PSC Branch received a class report satisfying the requirements
Operations/Management › Ballast Water Managment › Sediments
Issued 7 March 2017Resolved
9900 Other(not clearly hazardous)Remove foulind organisis from vessels hull, piping and tankson a regular basis and dispose of substances IAW local, state and Federal regulations. PSCOs noted excessive fouling organisms. 33CFR151.2050(f)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 March 2017
Resolved 29 April 2017
Resolution: PSC NOLA received a class report from BV satisfying the requirement.
Construction/Loadline › Markings › Load Line Mark
Issued 7 March 2017Resolved
1299 Other (load lines)The mark of authority by whom the loadlines are assigned may be indicated along the loadline ring above the horizontal line this mark shall consist of inital identifying the authorities name. Vessel has the old Class Society permenantly mounted and existing temp mounted.ICLL 96 am, annex I/7
Condition: Improper Installation
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 March 2017
Resolved 29 April 2017
Resolution: PSC NOLA received a class report from BV satisfying the requirement.
Fire Fighting › Structural - A Class Divisions › Doors
Issued 7 March 2017Resolved
Structual fire protection systems shall be kept in good working order so as to ensure their required preformance if a fire occurs. PSCOs noted four A-0 self closing fire doors not operating correctly or being held back with non automatic releases. SOLAS II-2/14.32.2.1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 March 2017
Resolved 9 March 2017
Resolution: Recieved BV class report stating that doors were adjusted and operating correctly.
0117-Continuous Synopsis Record. The Continuous Synopsis Record shall be issued by the Administration to each ship that is entitled to fly it's flag shall contain the following information. The name and address of the registered owners. PSCO noted that required information is missing from the vessels CSR. SOLAS XI-1-5.6
Condition: Invalid
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 March 2017
Resolved 29 April 2017
Resolution: PSC NOLA received a class report from BV satisfying the requirement.
Lifesaving › Lifeboat › Hatches
Issued 7 March 2017Resolved
0610 Lifeboats. every totally enclsoed lifeboat shall be provided with rigid watertight enclosure which completly encloses the lifeboat. The enclosure Hatch had a notable crack. SOLAS III/31.1.1, LSA 4.6.2.2
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 7 April 2017
Resolved 29 April 2017
Resolution: PSC NOLA received a class report from BV satisfying the requirement.
9800 Other (Clearly Hazardous) Cylinders must always be secured, and when not in use, they must be stowed in a rack in an upright position with the protection cap in place. PSCOs noted that the vessel had numerous cylinders tied down with ropes and stored in the deck locker on the deck without any dunnage or protection. 46CFR147.60
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 29 April 2017
Resolution: PSC NOLA received a class report from BV satisfying the requirement.
1099-Other (alarm – signals)-PSCO observed on ships service gernerator #3 that the fuel leak alarm had been bypassed and there was an active leak. SOLAS (14) II-2/4.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 23 June 2016
Resolved 1 July 2016
Resolution: Received Class report attesting to the satisfactory repairs #3 service generator fuel leak alarm.
1430-Auxiliary engines-PSCO Observed that ships service generator #2 is currently under maintenance. With the reference to deficiency #1, the vessel currently only has one ships service generator that is fully functioning. SOLAS (14) II-1/41.1.1
Action required: 17 - Rectify deficiencies prior to departure
Due 23 June 2016
Resolved 1 July 2016
Resolution: Received Class report attesting to the satisfactory repairs #2 service generator.
Electrical › Electric Generation Source (emergency) › Generator
Issued 23 June 2016Resolved
1430-Auxiliary engines-PSCO Observed that ships service generator #2 is currently under maintenance. With the reference to deficiency #1, the vessel currently only has one ships service generator that is fully functioning. SOLAS (14) II-1/41.1.1
Action required: 17 - Rectify deficiencies prior to departure
Due 23 June 2016
Resolved 1 July 2016
Resolution: Received Class report attesting to the satisfactory repairs of the emergency generator.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 23 June 2016Resolved
0611-Lifeboat inventory-PSCO observed in 25-person lifeboat that only 21 food rations were kept in airtight packaging. SOLAS (14) III/43 LSA 4.4.8
Action required: 17 - Rectify deficiencies prior to departure
Due 23 June 2016
Resolved 5 July 2016
Resolution: Received reciept of 04 food rations.
1099-Other (alarm-signals)-PSCO observed that the turbo pyrometer on #1 service generator was disconnected from the junction box. SOLAS (14) I/11
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 1 July 2016
Resolution: Received Class report attesting to the satisfactory repairs of turbo pyrometer.
1499-Other (Prop & Aux Machinery)-PSCO observed that the lagging on all service generators were visibly worn and hanging off of the piping. SOLAS (14) II-2/4.2.2.6.1
Action required: 705 - Other - as specified
Due 7 July 2016
Resolved 1 July 2016
Resolution: Received Class report attesting to the satisfactory repairs of exhaust lagging.
0699- Other (life saving appliances)- PSCO observed that there were no lifejacket donning instructions posted at the muster station. SOLAS III/8.4.3
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 23 June 2016
Resolution: Crew posted instructions prior to the conclusion of the examination.
Fire Fighting › Miscellaneous Items › B Class Division Penetrations
Issued 23 June 2016Resolved
2035-Fire control plan-PSCO observed that the A-60 self closing door (as per fire control plan) between stairwell and the gallery was not self-closing.
Action required: 705 - Other - as specified
Due 23 June 2016
Resolved 23 June 2016
Resolution: Crew repaired the door and PSCO verified proper operation prior to the conclusion of the examination.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.