Records from 2016 to 2026. Most recent: inspection, 29 June 2026.
Inspection history · 11
29 June 2026
COE-Administrative
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8418408
14 July 2025
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8185773
25 June 2025
Deficiency Check · PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 8167420
8 March 2023
PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7647466
7 April 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7170343
30 March 2021
PSC B
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7160506
7 March 2019
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6638411
22 August 2018
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6514863
13 August 2017
Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6238997
14 July 2017
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6203027
28 January 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 5794181
08 - Alarms › N/A - No Subsystem › UMS - alarms
Issued 25 June 2025
Resolved
The arrangements provided shall be such as to ensure that the safety of the ship in all sailing conditions,including manuvering,is equivalent to that of a ship having the machinery spaces manned.
PSCO observed fault code on #5 oil mist sensor.
74SOLAS(24)II-1/46.1
40BC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 27 June 2025
Resolution: Received satisfactory class report.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 25 June 2025
Resolved
The following fire protection systems shall be kept in good working order so as to ensure their required performance if a fire occurs: fire detection and alarm systems.
PSCO observed Co2 alarm siren missing from E/R floor port side alarm panel.
74SOLAS(09)II-2/14.2.1.1.2
10c
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 26 June 2025
Resolution: PSCO observed crew install siren on E/R floor port side alarm panel.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 25 June 2025
Resolved
Cargo ships shall carry at least one rescue boat complying with the requirements of the Code.
Except as provided by this section , all rescue boats shall comply with the requirements of paragraph 4.4.7.10.
A manually controlled exterior light shall be fitted.
PSCO observed nonoperational exterior light on rescue boat.
74SOLAS(24)III/31.2
LSA Code 5.1.1
LSA Code 4.4.7.10
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 26 June 2025
Resolution: PSCO observed crew replace the exterior light on rescue boat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 30 March 2021
Resolved
Vessel shall have 04 Sets of protective clothing, resistant to chemical attack, and be provided in addition to the firefighters outfits required by regulation 10.10. PSCO observed on 03 sets of protective clothing. Additionally, the 03 sets located were not in accordance with the vessels fire control plan.
SOLAS(74) 14 II-2/19.3.6.1
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2021
Resolved 7 April 2021
Resolution: Sector St. Petersburg recieved proper documentation attesting 02 chemical suits were ordered and recieved on vessel.
Fire Fighting › Fixed Fire Detection System › Detector/Call Point Grouping
Issued 14 July 2017
Resolved
0715-Detection-A fixed fire detection and fire alarm system shall be provided in accordance with the provisions of this regulation. PSCO observed fault in Zone 4 heat 20, Zone 5 heat 42, and loop analog 1. SOLAS 74/78 II-2/7.2.1 17a
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2017
Resolved 24 July 2017
Resolution: Crew repaired fire detection system. Zone 4 MCP 27 Received spare MCP from manufacturers Consilium. Crew replaced MCP No.20 with MCP No.27 and reprogrammed both; Zone 5 MCP 42 already rectified. Loop analog 1 replaced MCP 27 and fault is cleared.
Lifesaving › Lifeboat Equipment › Radio (fixed two-way VHF radio-telephone)
Issued 14 July 2017
Resolved
Before ship leaves port and at all times during voyage, all lifesaving appliances shall be in working order and ready for immediate use. PSCO observed expired batteries for EPIRB, VHF radios, and SARTS. SOLAS 74/78 III/20.2 17a
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2017
Resolved 24 July 2017
Resolution: Expired Batteries for EPIRB, SARTS & GMDSS VHF Hand-Held radios have been replaced
Fire Fighting › Portable Foam Applicators › General
Issued 14 July 2017
Resolved
Portable foam applicator unit shall consist of a foam nozzle of an inductor type together with a portable tank containining at least 20L of foam concentrate and at least one spare tank of foam concentrate of the same capacity. PSCO observed spare tank actively leaking contents with no replacement onboard. SOLAS 74/78 II-2/10.5.2.2.1 FSS Code 4.3.2.1
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2017
Resolved 24 July 2017
Resolution: Vessel received already 20 ltrs Foam concentrate and spare container.
Engineering › Fuel Oil Service System › Ventilation
Issued 14 July 2017
Resolved
The condition of the ship and its equipment shall be maintained to confrom with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed a temporary fan placed under the MGO controller. Unit will not run more than 30 minutes without over heating. SOLAS 74/78 I/11(b)
Action required: 17 - Rectify deficiencies prior to departure
Due 14 July 2017
Resolved 24 July 2017
Resolution: The temporary fan placed under the MGO controller Unit has been removed and reported to the
undersigned to be unnecessary and preventive only.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 14 July 2017
Resolved
Each transfer pipe system on board a vessel to be tested under static liquid pressure at least 1.5 times the maximum allowable working pressure annually. PSCO observed vessel did not test bunker lines. Provide hydrostatic test records prior to next bunkering in U.S. waters. 33CFR156.170
Action required: 15 - Rectify deficiencies by next port
Due 14 July 2017
Resolved 13 August 2017
Resolution: PSC NOLA received a proper documentation from vessel satisfying the requirement.