Records from 2016 to 2026. Most recent: inspection, 27 April 2026.
Documentation record
Registered dimensions (L × B × D)277.9 ft × 60.0 ft × 24.0 ft
Registered tonnagegross 4,226 / net 1,441
ITC dimensions (L × B × D)277.9 ft × 60.0 ft × 24.0 ft
ITC tonnagegross 4,226 / net 1,441
BuilderTAMPA SHIP LLC · TAMPA, FL, UNITED STATES · built 2013
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portGalliano, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 23 June 2026 · expires 30 June 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it4226 - Convention (Subpart B), Gross Ton
4942 - Dead Weight, Gross Ton
7550 - Displacement, Gross Ton
1441 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 17
27 April 2026
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8373943
29 September 2025
ACP Annual Oversight · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8228009
5 November 2024
ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8029236
20 October 2023
ACP COI Oversight · MTSA/ISPS Verification · Re-Inspection · COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7791500
10 January 2023
Administrative Inspection
Administrative · Activities Europe · Activity 7619727
17 November 2022
ACP Annual Oversight · Administrative Inspection · Annual Inspection
Physical examination · Activities Europe · Activity 7602403
21 October 2021
ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7336830
10 July 2020
Administrative Inspection · Annual Inspection · ACP Annual Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7002543
12 September 2019
Administrative Inspection · ACP Annual Oversight · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6810470
24 April 2019
Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6669256
4 September 2018
COI Inspection · MTSA/ISPS Verification · Annual Inspection · ACP COI Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6531396
30 August 2018
Administrative Inspection · Annual Inspection · ACP COI Oversight
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6526526
26 August 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6572848
24 August 2018
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6526788
2 August 2017
Annual Inspection · MTSA/ISPS Verification · ACP Annual Oversight · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6228066
24 August 2016
Administrative Inspection · ACP Annual Oversight · MTSA/ISPS Verification · Annual Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5982292
11 July 2016
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5959627
10 - Safety of Navigation › N/A - No Subsystem › Rudder angle indicator
Issued 29 September 2025
Resolved
Each vessel fitted with controllable pitch propellers, must have an indicator readable from the centerline conning position showing the pitch and operational mode of such propeller. Pitch indicator at emergency control station was defective and moving erradically.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2025
Resolved 30 September 2025
Resolution: Faulty part replaced and tested satisfactorilly.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 29 September 2025
Resolved
Each enclosed space within the vessel must be properly vented or ventilated. Portside Cargo Area Supply Fan is inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 October 2025
Resolved 30 September 2025
Resolution: Comm address for the vdf feedback in the PLC program was incorrect. Changed it and is back on service.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 September 2025
Resolved
An alarm system shall be provided indicating any fault, including an alarm for failure of the normal power supply of the alarm system. Nav lights work, but the alarm panel in the engine control room showed an active alarm for Navigation Light Power Failure.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 October 2025
Resolved 1 October 2025
Resolution: Replaced faulty fuse that was back-feeding wrong signal.
14 - Pollution Prevention › 146 - MARPOL Annex VI › Bunker delivery notes
Issued 29 September 2025
Resolved
Bunker delivery notes shall be accompanied by a representative sample of the fuel oil delivered. The sample must be retained under the ship's control for at least 12 months. Fuel samples for September 6 were missing.
MARPOL VI/18.8.1
Action required: 10 - Deficiency Rectified
Due 6 October 2025
Resolved 29 September 2025
Resolution: The company had fuel samples stored at a different location and was was replaced onboard the vessel.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 29 September 2025
Resolved
Entries shall be made in the Oil Record Book and shall be fully recorded without delay. Bunkering entries were made in Part II instead of Part I, certain entries were missing, and other entries were recorded inaccurately omitting exact fuel quantities.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 29 September 2025
Resolved 29 September 2025
Resolution: Chief Engineer corrected all log entries and scheduled remedial training with engineering staff.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 November 2022
Resolved
Main and emergency switchboards shall be so arranged as to give easy access as may be needed to apparatus and equipment, without danger to personnel. The sides and the rear and, where necessary, the front of switchboards shall be suitably guarded. Exposed live parts having voltages to earth exceeding a voltage to be specified by the Administration shall not be installed on the front of such switchboards. Where necessary, nonconducting mats or gratings shall be provided at the front and rear of the switchboard. Space provided in rear of main switchboard is missing the nonconductive matting. SOLAS (14) II-1 reg 45
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 17 November 2022
Resolved 17 November 2022
Resolution: Installed matting.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 November 2022
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or
touched in the normal manner. Vessel has three locations of dead-end wiring. 01 in vicinity of the f/o transfer appliances,01 in the access provided under the local steering controls of the after steering compartment and 01 in way of uninstalled sanitary pumps along the aft bulkhead of the machinery space. SOLAS(14)II-1 reg 45
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 17 November 2022
Resolved 18 November 2022
Resolution: Dead-end wiring secured or removed.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 17 November 2022
Resolved
Simple operating instructions with a block diagram showing the change-over procedures for remote
steering gear control systems and steering gear power units shall be permanently displayed on the navigation bridge and in the steering compartment. Instructions currently posted in the steering compartment do not accurately reflect change over procedure. SOLAS(14)V reg 26
Action required: 10 - Deficiency Rectified
Due 17 November 2022
Resolved 18 November 2022
Resolution: Instructions corrected by CHENG.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 November 2022
Resolved
...means shall be provided to control leaks of flammable liquids. 03 flanges the immediate vicinity of the main discharge metering device located in the main space has visible F/O leaking. SOLAS(14)II-2 Reg 4
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 17 November 2022
Resolved 17 November 2022
Resolution: All three flanges were found with lose hardware. Tightened to spec to prohibit f/o leak.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 November 2022
Resolved
The venting system shall be provided with devices to prevent the passage of flame into the cargo tanks. The
design, testing and locating of these devices shall comply with the requirements established by the Administration based on the guidelines developed by the Organization. 03 F/O tank vents on deck had insufficient hardware to secure the flame screens. SOLAS(14)II-2 Reg 4
Action required: 10 - Deficiency Rectified
Due 17 November 2022
Resolved 18 November 2022
Resolution: Hardware renewed. Flame screen secured properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 July 2020
Resolved
Periodic Safety Test must demonstrate the proper operation of primary and alternate controls; Vsl documented however failed to follow through on broken high coolant water temperature switch on the Port main engine approximately 120 ago; make corrections per approved PTSP
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2020
Resolved 20 July 2020
Resolution: Vessel provided documentation for installed high coolant water temp switch
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 10 July 2020
Resolved
Vessel's oily water separator is required to meet the design and construction requirements of MEPC107(49). A manual recirculating facility is required to be installed immediately adjacent to oily water OVBD valve,installed in such a way so as to prevent by-pass of OWS. As currently configured, the manual recirculation valve is installed in such a way as to permit by-passing of OWS.
MARPOL Reg 14-MEPC.107(49)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 August 2020
Resolved 13 July 2020
Resolution: Vsl installed check valve