A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 20 April 2026
Resolved
Settings of the safety or relief valves on all pressure vessels,tested twice every 5 years. Relief valves on engine room air receivers were not tested.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 20 April 2026
Resolved 29 April 2026
Resolution: Relief valves tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 April 2026
Resolved
A drip pan must be mounted & fitted under the strainer for machinery. Drip pans were missing from strainers and none of them were mounted to prevent movement.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 29 April 2026
Resolution: Drip trays secured.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 20 April 2026
Resolved
Each cable installation must meet IEEE. Metallic band strapping used for cable support should be applied so that cables remain tight without damage. Cables above Stbd main exhaust held up by ratchets straps.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 29 April 2026
Resolution: supports corrected.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 April 2026
Resolved
Electrical installations on vessels must ensure the protection of crew, other persons and the vessel from electrical hazards. Multiple battery covers not secured in the engine room and batteries in electrical room exceeding the size of the rack.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 29 April 2026
Resolution: Battery covers and rack arrangements corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 20 April 2026
Resolved
Propeller on a rescue boat must be fitted with a guard with a maximum opening of 3 in. on all sides on which a person is likely to be exposed. Guard does not provide protection required.
46 CFR 160.156-7
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 29 April 2026
Resolution: Prop guard replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 20 April 2026
Resolved
Rescue boat must be marked with Hailing port on both sides bow and reflective tape on bottom. Missing markings.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 29 April 2026
Resolution: Boat markings corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2026
Resolved
Pressure vessels must be examined or tested every 5 years. Dive supervisor unable to find documentation for tool air receiver & relief valve tests PRIOR TO USE.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 April 2026
Resolved 29 April 2026
Resolution: Recorded serial number and verified testing completed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 20 April 2026
Resolved
Installations accepted as meeting requirements must be maintained. Multiple penetrations in E/R not maintained.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2026
Resolved 29 April 2026
Resolution: Sealed.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 13 February 2025
Resolved
Each fire hose must be marked with the vessel's name. Fire house was not marked with vessel’s name.
Mark fire hoses with vessel name.
46 CFR 131.880
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 March 2025
Resolved 14 February 2025
Resolution: Hoses marked with vessel name.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 27 December 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 27 January 2023
Resolved 3 January 2023
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 27 December 2022
Resolved
Steering Gear System Pump #2 is inoperable.
Condition: Design Flaw
Action required: 17 - Rectify deficiencies prior to departure
Resolved 29 December 2022
Resolution: Pump #2 repaired (bad elec. card), test sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 11 January 2022
Resolved
46 CFR 97.40-15
Vessels assigned a load line shall have the deck line
and load line marks permanently scribed or embossed;Load
Line not legible; must be painted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2022
Resolved 18 January 2022
Resolution: VSL Painted Loadline tree and deckline.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 January 2022
Resolved
46 CFR 58.25-20(c)(1)
Each hydraulic system must be provided with arrangements to maintain the cleanliness of the hydraulic fluid; Steering gear arrangement found leaking hydraulic fuel, must be repaired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2022
Resolved 18 January 2022
Resolution: Steering space was clean, no major leaks detected however ram seals are seeping. Recommended replaceing seals at next drydock.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 January 2022
Resolved
46 CFR 56.50-75 (b)(3)
46 CFR 56.50-70 (b)
All fuel pipes, pipe connections, and accessories shall be effectively secured. A leaking fuel pipe was found covered in duct tape. Leak needs to be properly secured and duct tape removed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2022
Resolved 19 January 2022
Resolution: Repairs inspected to the satisfaction of the attending marine inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 11 January 2022
Resolved
33 CFR 159.101
A recognized facility must perform test described in 33 CFR 159.21. Excessive sewage odor was protruding from vessel's MSD. MSD needs to be serviced.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 January 2022
Resolved 18 January 2022
Resolution: Leak under galley sink has been fixed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 26 August 2021
Resolved
Bilge and ballast must be arranged as to prevent water from the sea from passing into machinery spaces. Installed stop valves were allowing sea water ingress in vessel.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 4 September 2021
Resolution: Witnessed test of bilge system
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 5 January 2021
Resolved
Except a disposable hydrostatic release unit with an expiration date, each hydrostatic-release unit must be service within 12 months of its manufacturer. EPIRB hydrostatic release was expired.
Action required: 17 - Rectify deficiencies prior to departure
Due 5 January 2021
Resolved 21 January 2021
Resolution: Vessel representative installed new hydrostatic release unit and attached to the vessel's EPIRB.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 5 January 2021
Resolved
Each item of survival equipment with an expiration date must be replaced during the annual inspection and repair if this date has passed; EPIRB NOAA Registration was expired on vessel's EPIRB.
Action required: 10 - Deficiency Rectified
Due 5 January 2021
Resolved 5 January 2021
Resolution: Vessel rep checked and found NOAA registry documentation in the office and placed updated sticker onto the EPIRB.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 January 2021
Resolved
Except as provided by paragraph (b) or (c) of this section, as appropriate for the intended voyage, each vessel must carry adequate and up-to-date: (1) Charts of large enough scale to make safe navigation possible.; Paper and electronic charts were 02 months out of date from most recent NTM corrections.
Action required: 10 - Deficiency Rectified
Resolved 5 January 2021
Resolution: Vessel representative corrected paper charts and brought onboard a chart correction kit to perform future corrections.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 January 2021
Resolved
Exhaust pipe installations must conform to the requirements of ABYC P-1; Exhaust piping from port main diesel engine was deteriorated due to exhaust leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2021
Resolved 11 January 2021
Resolution: Vessel representative sent photographic evidence of new insulation on exhaust line being attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 January 2021
Resolved
Nonmetallic flexible hose may be used in lube oil, fuel oil, and fluid power systems only where flexibility is required and in lengths not exceeding 30 inches; Fuel hose on dive generator set exceeded 30 inches in length.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2021
Resolved 11 January 2021
Resolution: Vessel representative provided photographic proof of fuel hose length being shortened to 30 inches.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 5 January 2021
Resolved
Nonmetallic flexible hose must be in accordance with SAE J1942; Fuel hose on vessel's winch prime mover was wasted due to continuous contact with pressure gauge and engine frame.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 January 2021
Resolved 11 January 2021
Resolution: Vessel representative provided photographic evidence of chafing gear being placed around area of fuel hose that was making contact with pressure gauge and engine frame.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 5 January 2021
Resolved
Tests and inspections of lifesaving equipment shall be carried out during each inspection for renewal of certification and periodic inspection and shall demonstrate, as applicable: The proper condition of flotation equipment such as lifebuoys; 01 ring buoy had water intrusion.
Action required: 10 - Deficiency Rectified
Resolved 5 January 2021
Resolution: Vessel representative placed new ring buoy into service and condemned the other one in the presence of CG Marine Inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 January 2021
Resolved
Vessels over 79 feet in length must have a valid Vessel General permit; Vessel did not have VGP onboard and no proof of one on VGP database.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 February 2021
Resolved 21 January 2021
Resolution: Vessel representative provided photographic evidence of a valid Vessel General Permit.
01 - Certificates & Documentation › 011 - Ships Certificates › Load Lines (including Exemption)
Issued 5 January 2021
Resolved
A ship shall be subjected to the surveys specified below: An annual survey within 3 months before or after each anniversary date of the certificate; Vessel's anniversary date for load line survey was 29AUG. Vessel was unable to have annual load line survey complete in 3 month window preceding anniversary date. Vessel logs indicated that vessel was in operation beyond boundary line for 04 days between 08DEC20-12DEC20. ABS conducted load line survey on 15DEC20.
Action required: 10 - Deficiency Rectified
Resolved 5 January 2021
Resolution: Vessel representative was counseled on ensuring Load Line certificate is valid prior to conducting operations.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 17 January 2020
Resolved
Install emergency lighting to ensure it illuminates both port and stbd embarkation stations on the back deck.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 January 2020
Resolution: Emergency lights were installed and tested on the main deck.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 January 2020
Resolved
Exposed wiring on port engine, batteries, and on the dive compressor engine. Wrap all exposed wires.
Action required: 10 - Deficiency Rectified
Due 30 January 2020
Resolved 17 January 2020
Resolution: Vessel corrected deficiencies on the spot by replacing or wrapping wires with electrical tape.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 17 January 2020
Resolved
Ensure drills are conducted and logged properly IAW each sub-chapter the vessel is authorized to work i.e. Sub-chapter (L) and (I). The most stringent is Sub L and the fire drill & Abandoned ship drill should be conducted on alternating weeks. Cited 46CFR199.180(I service); 46CFR131.530(b)& 46CFR131.535(a).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2020
Resolved 31 January 2020
Resolution: Drill log in the last two weeks shows proper logging.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 January 2020
Resolved
Provide original copy of the FCC station license for all radio equipment on board. Cited 47CFR80.13
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 January 2020
Resolved 31 January 2020
Resolution: Provided copy of radio safety cert.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 October 2014
Resolved
Vessel had was operating with only a copy of valid COI. Crew member stated that it was all they had since delivery last year.
Action required: 705 - Other - as specified
Resolved 13 November 2018
Resolution: Resolved
Lifesaving › Lifebuoys › Serviceable
Issued 8 October 2014
Resolved
Found two lifebuoys were waterlogged
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 October 2014
Resolution: Corrected before inspection complete
Operations/Management › Drills/Instruction › Not Conducted
Issued 8 October 2014
Resolved
Emergency drills not being conducted. Vessel rep and captain blamed recently fired master. CG-835 to remain open until next annual inspection.
Action required: 705 - Other - as specified
Resolved 13 November 2018
Resolution: resolved
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 8 October 2014
Resolved
Vessel not conducting weekly & monthly checks IAW subchapter L lifesaving 46CFR131.560/565. CG-835 to remain open until next annual inspection.
Action required: 705 - Other - as specified
Resolved 13 November 2018
Resolution: resolved
Documentation › Logs/Records › Garbage Recordkeeping
Issued 8 October 2014
Resolved
No garbage recordkeeping since vessel delivery. CG-835 to remain open until next annual.
Action required: 705 - Other - as specified
Resolved 13 November 2018
Resolution: resolved
Documentation › Logs/Records › Logbook (official)
Issued 8 October 2014
Resolved
Logbook not being maintained and required entries have not been made since vessel delivery. CG-835 to remain open until next annual.
Action required: 705 - Other - as specified
Resolved 13 November 2018
Resolution: resolved
Fire Fighting › Means of Escape › Doorways
Issued 8 October 2014
Resolved
Emergency escape from engine room unable to be opened from inside.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 October 2014
Resolution: Cleared during annual ABS laodline exam.
Construction/Loadline › Structures › Door
Issued 8 October 2014
Resolved
All watertight doors in the Engine room were blowing by air when sealed. Vessel must make adjustments and check watertight integrity regularly.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 October 2014
Resolution: Cleared during annual ABS loadline exam
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 8 October 2014
Resolved
Non-Tank Vessel response plan not approved. Company has approved NTVRP with other vessel in fleet. Vessel must add to existing OSRO contract.
Action required: 705 - Other - as specified
Due 8 November 2014
Resolved 8 November 2014