Records from 2017 to 2025. Most recent: inspection, 29 July 2025.
Inspection history · 9
29 July 2025
Administrative Inspection
Administrative · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8197445
21 July 2025
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8188907
29 May 2024
Administrative Inspection · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7922249
25 February 2021
PSC B
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7138710
12 February 2021
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7140170
9 November 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Marine Safety Unit Portsmouth · USCG Northeast District (CGD-NE) · Activity 6577938
11 September 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6262570
5 September 2017
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6259625
29 August 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6250535
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 29 May 2024
Resolved
The means of embarkation and disembarkation shall be constructed and installed based on the guidelines developed by the organization. Upon arrival, PSC officers were not able to safely embark the vessel to conduct PSC exam due to positioning of the gangway and accommodation ladder.
74 SOLAS (20) II-1/3-9.2
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 30 May 2024
Resolution: vessel placed magnets on the pilot ladder to sceure it to the hull and added ballast while at berth. Inspectors were able to safely get on and get off the vessel.
14 - Pollution Prevention › 141 - MARPOL Annex I › Segregation of oil and water ballast
Issued 29 May 2024
Resolved
"FOLLOWING INSTALLATION, THE MASTER... INCHARGE OF THE VESSEL SUBJECT TO THIS SUBPART MUST PROPERLY MAINTAIN THE BWMS IN ACCORDANCE WITH ALL MANUFACTURER SPECIFICATIONS." VESSEL REPORTED INOPERABLE BWMS. 33CFR151.2025(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 July 2025
Resolution: EXAMPLE: PSC NOLA received a class report from Nippon Kaiji Kyokai satisfying the requirement.
Operations/Management › Pollution › SECA
Issued 29 August 2017
Resolved
2430-While Ships are within ECA the sulphur content of fuel oil used onboard ships shall not exceed the following limits: .10%m/m on or after 01 January 2015. Vessel used high sulfur fuel in the ECA. MARPOL VI/14.4.3 17a,c
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2017
Deck/Cargo › Holds/Tanks › Cargo Tank Arrangement/Size
Issued 29 August 2017
Resolved
1110- Prior to loading a solid bulk cargo, the master shall be in possesion of comprehensive information on the ships stability and on the distribution of cargo for the standard loading conditions. PSCO noted vessel's stability and loading booklets so not have known loading conditions for sailing with cargo hold #3 empty. 74SOLAS(14) VI/6 17a,c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2017
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 29 August 2017
Resolved
0999- Doors required to be self closing shall not be fitted with hold back hooks. PSCO noted that all self closing doors have hold back hooks permanently installed. 74SOLAS(14) II-2/9.4.2.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 September 2017