Records from 2016 to 2025. Most recent: inspection, 29 May 2025.
Documentation record
Registered dimensions (L × B × D)40.0 ft × 14.0 ft × 4.5 ft
Registered tonnagegross 16 / net 16
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWILLIAM E MUNSON COMPANY · BURLINGTON, WA, UNITED STATES · built 2013
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationMonohull
Hailing portBridgeport, CT
Trade endorsementsCoastwise, unrestricted, Recreational
DocumentationValid · issued 24 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Simplified, Gross Ton
16 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 14
29 May 2025
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8147513
29 May 2024
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7922489
12 June 2023
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7715830
9 May 2023
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7684453
28 June 2022
Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7476068
23 March 2022
Re-Inspection · Plan Review "T" Boat
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7417306
24 May 2021
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7193654
9 April 2021
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7171850
11 August 2020
Administrative Inspection
Administrative · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7029932
7 June 2019
COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6702951
22 June 2018
Internal Structural Exam · Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6452497
18 January 2018
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6339878
18 May 2017
Internal Structural Exam · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6149354
12 May 2016
Deficiency Check · Internal Structural Exam · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5875517
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 June 2022
Resolved
Gasoline vapor detection system not operable. System must be able to alert crew of vapor in gasoline tank space.
Action required: 17 - Rectify deficiencies prior to departure
Due 28 June 2022
Resolved 13 September 2022
Resolution: Vapor detection system is operational.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 28 June 2022
Resolved
Vsl missing 1 of 3 fire buckets. Must have 3 fire buckets 2.5 gallon with the bucket stenciled "Fire Bucket" with a sufficient size length lanyard to reach water.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 13 September 2022
Resolution: Vsl has all 3 fire buckets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 June 2022
Resolved
#1 and #3 bilge high level alarms not working. All bilge alarms need to provide audible and visual alarm at the operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 13 September 2022
Resolution: Both high water alarms working as required.
10 - Safety of Navigation › N/A - No Subsystem › Life-saving signals
Issued 28 June 2022
Resolved
Flares onboard vessel are expired. For route vessel is required approved flares either 3 red & 3 orange smoke or 6 red.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 13 September 2022
Resolution: Vsl has required flares onboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 28 June 2022
Resolved
All vessels voids below deck hatches are not sealing as design. Flush hatches need to be maintained and seals cleaned. Bilges need to be dewatered.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 13 September 2022
Resolution: All deck hatch voids are maintained and sealing as required.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 28 June 2022
Resolved
Ring life buoy required waterlight not working. Light is required to work and attached to ring life buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 July 2022
Resolved 13 September 2022
Resolution: RLB light working as required.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 11 August 2020
Resolved
Vessel did not have required dry dock/ISE completed due to COVID -19
Action required: 701 - Prior to carriage of passengers/cargo
Due 31 January 2021
Resolved 9 April 2021
Resolution: Dry dock completed.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 22 June 2018
Resolved
Provide light list.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2018
Resolved 17 July 2018
Resolution: light list printed
Navigation › Piloting/Steering › US Coast Pilot
Issued 22 June 2018
Resolved
Provide coast pilot
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2018
Resolved 17 July 2018
Resolution: coastpilot printed
Navigation › Piloting/Steering › Local Notices to Mariners
Issued 22 June 2018
Resolved
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2018
Resolved 17 July 2018
Resolution: Notice to mariners printed.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 22 June 2018
Resolved
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2018
Resolved 17 July 2018
Documentation › Markings/Placards › Lifejacket Placard
Issued 22 June 2018
Resolved
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2018
Resolved 17 July 2018
Resolution: placard posted.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 12 May 2016
Resolved
Vessel was missing required B-I fire extinguisher. Provide required number of B-I fire extinguishers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2016
Resolved 1 June 2016
Resolution: Extinguisher provided.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 May 2016
Resolved
Vessel had expired items in its first aid kit. Provide first aid kit with items that have not reached expiration.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2016
Resolved 23 May 2016
Resolution: Vessel purchased brand new first aid kits.
Engineering › Bilge Water Management System › Pump
Issued 12 May 2016
Resolved
Void #1 bilge pump will not shut off once activated. Provide a properly operating bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2016
Resolved 23 May 2016
Resolution: Vessel replaced bilge pump with a properly operating and tested bilge pump.
Engineering › Bilge Water Management System › Interface Detector
Issued 12 May 2016
Resolved
Void #4 high water alarm was not working. Provide a properly operating bilge high water alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2016
Resolved 23 May 2016
Resolution: Vessel had technician come in and test high water alarm. It was found to be properly operating. MI came out and varified through operational testing.