MAURY USCG vessel records
← All vessels

KIRBY 16831

KIRBY 16831 is a 2013 tank barge. The Coast Guard has recorded 15 inspections since 2013, most recently in November 2024, along with 4 deficiencies.

Records from 2013 to 2024. Most recent: inspection, 5 November 2024.

Built
2013
Last inspected
5 November 2024
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 5 November 2024
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2013–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

1244997
Flag
UNITED STATES
Maury page id
psix-1244997

Documentation record

Registered dimensions (L × B × D)245.0 ft × 48.0 ft × 12.0 ft
Registered tonnagegross 1,185 / net 1,185
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCONRAD ORANGE SHIPYARD INC · ORANGE, TX, UNITED STATES · built 2013
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 July 2026 · expires 31 August 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1185 - Simplified, Net Ton
1185 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 15

5 November 2024 Administrative Inspection
Administrative · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 8029813
23 April 2024 Examination of Repairs
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 7900188
25 January 2024 In-Service Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7852941
26 December 2023 Drydock Exam · MTSA Verification · Cargo Tank Internal · COI Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7842590
12 March 2021 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7149775
28 February 2020 MTSA Verification · Annual Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6917475
6 February 2019 Bulk Liquid Transfer Monitor
Physical examination · Marine Safety Unit Huntington · USCG Heartland District (CGD-H) · Activity 6621573
12 December 2018 In-Service Inspection · Internal Structural Exam · COI Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6599527
19 October 2017 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6295219
17 October 2017 Annual Inspection · Administrative Inspection · MTSA Verification
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 6289986
1 June 2016 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5894231
7 March 2016 Periodic Inspection
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 5829337
27 February 2015 Administrative Inspection · Annual Inspection
Physical examination · Sector Lower Mississippi · USCG Heartland District (CGD-H) · Activity 5077039
12 November 2013 Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 4752829
21 October 2013 Initial Certification · Internal Structural Exam · Construction Oversight · MTSA Verification · Hull Examination · Cargo Tank Internal
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 4757876

Deficiency record · 4

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 18 October 2017 Resolved
Multiple quick-closing safety valves failed to close in 10 seconds or less prior to conducting cargo operations. 46 CFR 151.20-5(f)
Action required: 705 - Other - as specified
Resolved 19 October 2017
Resolution: New actuators were installed at Universal barge repair. Witnessed all quick-closing valves close 3x's at 8 seconds or less.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 18 October 2017 Resolved
Tighten all piping support brackets 46 CFR 38.10-10(c)
Action required: 705 - Other - as specified
Due 17 November 2017
Resolved 19 October 2017
Resolution: Verified all pipe supports had been retightened.
Electrical › Electrical Distribution System (service) › Cable
Issued 18 October 2017 Resolved
Properly support loose electrical conduit in vicinity of aft cargo headers. 46 CFR 38.15-15
Action required: 705 - Other - as specified
Due 17 November 2017
Resolved 19 October 2017
Resolution: Electrical conduit had new medal straps installed around cargo header.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 October 2017 Resolved
Vessel missed third year annual inspection. No cargo operations are authorized until vessel is inspected by a USCG Marine Inspector.
Action required: 705 - Other - as specified
Resolved 18 October 2017

Ownership record