ADVANTAGE VALUE is a tank ship. The Coast Guard has recorded 4 inspections since 2019, most recently in August 2025, along with 4 deficiencies.
Records from 2019 to 2025. Most recent: inspection, 30 August 2025.
- Built
- Not recorded
- Last inspected
- 30 August 2025
- Documentation
- Not in the documentation file of 10 August 2026
- Deficiencies
- 4 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9376749
V7A2730
1247288
Flag
MARSHALL ISLANDS
Maury page id
psix-1247288
Inspections, by type
Years with a record
4 calendar years (2019–2025)
The 4 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Documentation record
Tonnage as PSIX records it98937 - Convention (Subpart B), Net Ton
339151 - Displacement, Metric Ton
297556 - Dead Weight, Metric Ton
156702 - Convention (Subpart B), Gross Ton
339151 - Displacement, Metric Ton
297556 - Dead Weight, Metric Ton
156702 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
A report is not offered for this hull: Its record holds only 1 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 4
30 August 2025
COC-TVE Renew · PSC B
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8219393
28 April 2024
PSC B · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7902651
1 May 2022
PSC B · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7440948
24 January 2019
COC-TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6612951
Deficiency record · 4
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 January 2019
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed leaks on the main engine, speficially on the #2 piston. 74SOLAS(14)II-2/4.1.1
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 January 2019
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: the ignition sources shall be restricted. PSCO observed oil soaked lagging on the main engine. 74SOLAS(14)II-2/4.1.4
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 January 2019
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: the ignition sources shall be restricted. PSCO observed oil on the stripping pump in the cargo pump room. 74SOLAS(14)II-2/4.1.4
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 24 January 2019
Resolved
The tank overfill required by paragraph (a) of this section must: be identified with the legend "TANK OVERFILL ALARM" in black letters at least 50.87 millimeters (2 inches) high on a white background. PSCO observed no signage for overfill alarm. 46CFR39.2007
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.