MAURY USCG vessel records
← All vessels

CAPE HORN

CAPE HORN is a 2014 offshore supply vessel. The Coast Guard has recorded 26 inspections since 2016, most recently in February 2026, along with 10 deficiencies and 1 casualty investigation in 2023.

Records from 2016 to 2026. Most recent: inspection, 3 February 2026.

Built
2014
Last inspected
3 February 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9744611
WDP8158
1249788
Flag
UNITED STATES
Maury page id
psix-1249788

Inspections, by type

…with no type recorded1
Years with a record 10 calendar years (2016–2026)
The 26 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Offshore class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)195.8 ft × 48.0 ft × 16.0 ft
Registered tonnagegross 1,426 / net 427
ITC dimensions (L × B × D)195.8 ft × 48.0 ft × 16.0 ft
ITC tonnagegross 1,426 / net 427
BuilderGULF ISLAND MARINE FABRICATORS LLC · HOUMA, LA, UNITED STATES · built 2014
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 30 July 2026 · expires 31 July 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it427 - Convention (Subpart B), Net Ton
1903 - Dead Weight, Gross Ton
1426 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 26

3 February 2026 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8296278
4 August 2025 Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8202112
23 June 2025 In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8161409
14 November 2024 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8031932
29 October 2024 Cargo Tank Internal · Drydock Exam · Administrative Inspection · Examination of Repairs · Internal Structural Exam · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8026101
18 June 2024 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7937714
5 February 2024 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7861151
6 December 2023 Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7839097
24 January 2023 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7626826
30 November 2022 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7592191
20 October 2022 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 7580965
14 September 2022 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7560486
3 May 2022 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7443352
11 April 2022 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7429033
4 April 2022 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7437825
31 March 2022 In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7421932
4 January 2022 Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7375318
12 August 2021 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7284043
26 January 2021 Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7131203
19 January 2021 Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7126527
15 November 2019 Administrative Inspection
Administrative · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6856240
21 October 2019 Administrative Inspection · MTSA Verification · Hull Examination · Drydock Exam · Cargo Tank Internal · Internal Structural Exam · COI Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6838771
18 December 2018 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6599807
16 January 2018 Periodic Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6338706
17 October 2017 Drydock Exam · Examination of Repairs · Internal Structural Exam · Administrative Inspection · Cargo Tank Internal
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6289658
15 November 2016 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6041727

Deficiency record · 10

14 - Pollution Prevention › 142 - MARPOL Annex II › Vent. Procedures/equipment
Issued 3 February 2026 Resolved
Vessels carrying Class C Cargo in bulk must have pressure relief valves for those tanks installed so that they are free from imperfections which may affect their serviceability. The vacuum test level fell off of methanol P/V valve STBD 2 and renders in untestable. Fix prior to loading cargo in tank. 46CFR153.1 46CFR153.368 46CFR162.017-3(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 March 2026
Resolved 4 February 2026
Resolution: Vacuum test handle was replaced and in good working order.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 24 January 2023 Resolved
Each ship of 400GT and above shall maintain an Oil Record Book Part I and maintain entries made on each occasion IAW 33CFR151.25(d) and the instruction in the Oil Record Book. Vessel was not properly logging entries for disposal, transfer, and operation of oil filtering equipment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 February 2023
Resolved 13 February 2023
Resolution: Company provided training to all crew regaurding ORB entries.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 24 January 2023 Resolved
[name withheld] indicating gage shall in no case be less than 1.2 nor more than 2 times the pressure which the relieving device is set to function. The Port ER PV relief was set to 200PSI and the gauge upper limit was 600PSI. Cleared by ABS surveyor on 24JAN2023.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 24 January 2023
Resolution: ABS Surveyor verified installiation of new pressure gauge.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 January 2022 Resolved
The lifebuoys on the port and starboard sides of the bridge deck have deteriorated plugs and are no longer watertight.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 4 January 2022
Resolved 4 January 2022
Resolution: Replaced plugs on both lifebuoys.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 4 January 2022 Resolved
The pressure relieving device is set to 175 PSI, and the gauge on the pressure vessel only went to to 200 PSI.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 February 2022
Resolved 19 January 2022
Resolution: New 300 psi pressure gauge was installed.
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 4 January 2022 Resolved
Vessel had expired alcohol test strips on board.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 4 January 2022
Resolved 4 January 2022
Personnel › Certificates/Documents/Licenses › MMD, Qualified Member of Engine Dept
Issued 15 November 2016 Resolved
COI Requires 1 Oiler, vessel had a AB with a wiper endorsement on board filling that position.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 November 2016
Resolved 15 November 2016
Resolution: AB replaced by a Chief Engineer.
Communications › Radio Communications › EPIRB
Issued 15 November 2016 Resolved
Hyrdostatic release on EPIRB expired.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 November 2016
Resolved 15 November 2016
Resolution: Hydro replaced.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 15 November 2016 Resolved
Vessel was short two self-igniting lights on two life bouys.
Action required: 17 - Rectify deficiencies prior to departure
Due 15 November 2016
Resolved 15 November 2016
Resolution: Total of 4 light installed.
Lifesaving › Inflatable Liferafts › Float Free
Issued 15 November 2016 Resolved
Painters were attached directly to the vessel, bypassing the weak link.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 November 2016
Resolved 15 November 2016
Resolution: Painter connected to weak link.

Casualty record · 1

6 December 2023Routine · role: Suspected Pollution Source · activity 7839097
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record