Records from 2016 to 2026. Most recent: inspection, 6 May 2026.
Documentation record
Registered dimensions (L × B × D)195.8 ft × 48.0 ft × 16.0 ft
Registered tonnagegross 1,427 / net 427
ITC dimensions (L × B × D)195.8 ft × 48.0 ft × 16.0 ft
ITC tonnagegross 1,427 / net 427
BuilderGULF ISLAND MARINE FABRICATORS LLC · HOUMA, LA, UNITED STATES · built 2015
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 30 July 2026 · expires 31 July 2027
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it427 - Convention (Subpart B), Net Ton
1903 - Dead Weight, Gross Ton
1427 - Convention (Subpart B), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 47
6 May 2026
Annual Inspection · MSP Additional Oversight - Risk Assessment
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8349740
20 February 2026
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8299453
14 April 2025
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8111498
25 February 2025
COI Inspection · Administrative Inspection · MTSA Verification · Deficiency Check
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8084612
12 February 2025
Cargo Tank Internal · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 8078193
5 June 2024
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7927525
28 September 2023
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7800129
24 August 2023
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7771274
31 May 2023
Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7701480
9 February 2023
Cargo Tank Internal · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7634708
13 October 2022
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7577293
14 September 2022
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7560482
8 June 2022
Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7471689
3 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7443236
7 April 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7426821
4 April 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7437758
18 March 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7414347
24 February 2022
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7401617
4 November 2021
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7345339
14 June 2021
In-Service Inspection · Annual Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 7224805
13 May 2020
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6952443
3 April 2020
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6935127
18 March 2020
Administrative Inspection · Internal Structural Exam · Cargo Tank Internal · Drydock Exam
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6931104
6 December 2019
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6945289
25 June 2019
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6724814
19 April 2019
Type not recorded
No type recorded · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6668308
27 November 2018
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6587269
10 October 2018
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6558806
1 August 2018
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6497044
7 June 2018
Administrative Inspection · Periodic Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6436561
8 March 2018
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6368507
20 February 2018
Internal Structural Exam · Cargo Tank Internal · Drydock Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6360180
6 November 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6301944
12 September 2017
Administrative Inspection
Administrative · Commandant (CG-ENG) · Activity 6264832
12 September 2017
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6265752
24 August 2017
Administrative Inspection
Administrative · Commandant (CG-ENG) · Activity 6250593
18 July 2017
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6212884
25 May 2017
In-Service Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6155025
1 May 2017
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6136442
20 April 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6129009
27 March 2017
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6112095
10 March 2017
Type not recorded
No type recorded · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6102533
16 February 2017
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6092242
15 August 2016
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5973565
25 May 2016
Administrative Inspection · Plan Review (Other than "T")
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5886729
13 April 2016
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5854094
24 March 2016
Administrative Inspection
Administrative · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 5842744
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 March 2025
Resolved
An emergency bilge suction must be provided in the machinery space for all self propelled vessels. Vessels over 180 feet in length which are not passenger vessels and operate in ocean routes, must be provided with a direct emergency bilge suction. The emergency bilge suction is unable to draw suction from the engine room.
46 CFR 56.50-50 (f) (3)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2025
Resolution: Vessel's C/E took apart check valve and found it stuck. Cleaned and greased and re-installed. Demonstrated to MI proper suction with water-in-bag method. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 12 March 2025
Resolved
All vessels must be provided with a satisfactory bilge pumping plant capable of pumping from and draining any watertight compartment. Bow thrsuter room is able to take suction however forward pump room is unable to take suction, unable to verify pumping capabilities in all watertight compartments.
46 cfr 56.50 (a) (2)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 13 March 2025
Resolution: Vessel's C/E took apart check valves and found branch line valves stuck. Cleaned and greased and re-installed. Demonstrated to MI proper suction with water-in-bag method. All sat.
14 - Pollution Prevention › 141 - MARPOL Annex I › Pumping, piping and discharge arrangements
Issued 5 June 2024
Resolved
Ships must have no discharge connections to bilge system or OWS except from holding tank. OWS discharge has OVBD bypass fitting. Plug and weld closed.
33 CFR 155.360
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2024
Resolved 5 June 2024
Resolution: The fitting was welded in place.
01 - Certificates & Documentation › 013 - Documents › Oil record book
Issued 5 June 2024
Resolved
Each ship 400 gross tons and above shall maintain oil record book Part 1 (machinery space opreations). Oil record book Part 1 and Part 2 entries being maintained in same book (Part 1). Discussed proper entries and records keeping with C/E. Corrected on the spot with MI's.
Action required: 10 - Deficiency Rectified
Resolved 5 June 2024
Resolution: Discussed with C/E proper procedures for maintaining records and entries. Correct on the spot with MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Minimum Safe Manning Document
Issued 5 June 2024
Resolved
Onboard seagoing vessel of 500 GT or more no person may serve as Chief Engineer, Officer of Engineering Watch unless person holds valid STCW endorsement. Chief Engineer does not have STCW endorsment III/1, Officer in Charge of Engineering Watch. Notifed C/E and vessel rep, Compnay got a new C/E onboard with proper credentials verified by MI. Corrected on spot.
46 CFR 15.1103
Action required: 10 - Deficiency Rectified
Resolved 5 June 2024
Resolution: Compnay got a new C/E onboard with proper credentials verified by MI. Corrected on spot prior to MI departure.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 31 May 2023
Resolved
Each lifesaving appliance and launching appliance must be visually inspected to ensure that it is ready for use. Jacob's cradle was not ready for use during man overboard drill. Make proper repairs to Jacob's cradle.
46 CFR 131.560(a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 July 2023
Resolved 28 June 2023
Resolution: Vessel rep provided photographic evidence of replaced cradle.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 31 May 2023
Resolved
Vessel with watertight doors in bulkheads must be made watertight. Engine room watertight doors were not watertight. Make watertight.
46 CFR 174.210(a)
Action required: 10 - Deficiency Rectified
Due 31 May 2023
Resolved 31 May 2023
Resolution: Doors were made watertight and verified by ABS.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 25 June 2019
Resolved
Vessel crew's knowledge of individual roles and responsibilities during fire drill was insufficient. Crew unable to properly dawn SCBA's and secure power to fire affected space. Crew did not muster in location as directed in station bill.
Vessel shall conduct all drills in the presence of an attending CG marine inspector prior to vessel movement.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 June 2019
Resolution: GS-12 Landry returned to vessel and witness crew run fire drill, sat.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 1 August 2018
Resolved
All electrical components installed in hazardous locations must comply with standards outlined in 46 CFR 111.105 while maintaining system integrity. Stern light cable located within hazardous zone was damaged compromising system integrity. Powe supply must be renewed to original condition to the satisfaction of the marine inspector.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 7 August 2018
Resolution: Vessel rep emailed proof of deficiency being rectified.
Electrical › Electric Generation Source (emergency) › Circuit Breaker
Issued 27 March 2017
Resolved
Was not able to bring the vessel onto emergency power.
Action required: 705 - Other - as specified
Due 27 March 2017
Resolved 28 March 2017