NORDORCHID is a tank ship. The Coast Guard has recorded 15 inspections since 2016, most recently in June 2026, along with 3 deficiencies and 2 operational controls.
Records from 2016 to 2026. Most recent: inspection, 16 June 2026.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it31074 - Convention (Subpart B), Net Ton 105651 - Dead Weight, Metric Ton 122245 - Displacement, Metric Ton 57081 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 15
16 June 2026PSC B · COC-TVE Renew
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8376601
4 June 2025COC-TVE Annual · PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8149031
19 December 2024Deficiency Check
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8049467
6 December 2024Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8044040
3 June 2024PSC B · COC-TVE Renew
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7923907
8 November 2023Bulk Liquid Transfer Monitor
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7822136
31 May 2023COC-TVE Annual · PSC B
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 7696961
17 July 2022Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7508846
22 May 2022COC-TVE Renew · PSC B · Administrative Inspection
10 - Safety of Navigation › N/A - No Subsystem › Radar
Issued 6 December 2024Resolved
EACH VESSEL OF 10,000 GROSS TONS OR MORE MUST HAVE, IN ADDITION TO THE RADAR SYSTEM UNDER 164.35, A SECOND MARINE RADAR SYSTEM THAT OPERATES INDEPENDENTLY OF THE FIRST. VESSEL SELF-REPORTED THAT S-BAND RADAR WAS INOPERABLE, AND RETAINS OPERABILITY OF THE X-BAND RADAR.
Cite: 33CFR164.37(a)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 30 January 2025
Resolved 19 December 2024
Resolution: Replaced power supply PCB. Confirmed goood operation.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2021Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the current regulations to ensure the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. The ship's emergency generator shuts down during operation unless the generator's overspeed alarm is bypassed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 April 2021
Resolved 20 April 2021
Resolution: Vsl submitted satisfactory Class Report.
01117-In every case, the Administration concerned shall fully guarantee thecompleteness and efficiency of the survey and shall undertake to ensure thenecessary arrangements to satisfy this obligation. PSCO observed the slop tanks information was not noted on the IOPP form B. 78Marpol(17) I/6.3.4 50a
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 October 2019
Resolved 10 September 2019
Resolution: SEC NOLA PSC/Arrivals Branch received a class report/proper documentation satisfying the requirement and cleared 01 deficiency
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.