← All vessels
RIDGEBURY PRIDE
RIDGEBURY PRIDE is a tank ship. The Coast Guard has recorded 20 inspections since 2003, most recently in July 2017, along with 13 deficiencies and 3 operational controls.
Records from 2003 to 2017. Most recent: inspection, 12 July 2017.
- Built
- Not recorded
- Last inspected
- 12 July 2017
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 13 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9180255 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
V7MP9
12508
Flag
ISLE OF MAN
—
Maury page id
psix-12508
Inspections, by type
…with no type recorded6
Years with a record
11 calendar years (2003–2017)
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it305994 - Dead Weight, Ton
348818 - Displacement, Ton
105889 - Convention (Subpart B), Net Ton
160216 - Convention (Subpart B), Gross Ton
348818 - Displacement, Ton
105889 - Convention (Subpart B), Net Ton
160216 - Convention (Subpart B), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
12 July 2017
ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6196056
14 May 2012
Deficiency Check · ISPS II Exam · Ballast Water Examination · COC-TVE Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4304893
15 February 2011
ISPS II Exam · Ballast Water Examination · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3943800
5 February 2010
ISPS II Exam · Ballast Water Examination · PII Safety Exam · COC-TVE Renew
Physical examination · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3672906
21 January 2009
ISPS II Exam · COC-TVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3395805
3 June 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3225360
3 June 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3226701
19 January 2008
COC-TVE Renew · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3131790
10 January 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3128428
9 January 2008
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3127629
9 May 2007
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2926160
5 January 2007
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2850988
21 January 2006
COC-TVE Renew
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2574677
20 September 2005
ISPS II Exam · Ballast Water Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2497407
7 September 2005
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2486799
6 September 2005
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2485960
22 November 2004
COC-TVE Annual
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2246384
2 June 2004
MTSA/ISPS Verification
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2086794
11 December 2003
Certificate of Compliance
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1962501
9 December 2003
Administrative Inspection
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2005556
Deficiency record · 13
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 13 July 2017
Resolved
CITE: 74 SOLAS (2014) I/II(A) CODE: 0999 ACTION: 40AC
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. PIN-HOLE LEAKS IN THE SEWAGE DRAIN LINE LEADING TO SEWAGE HOLDING TANK AND MSD.
Engineering › Generator (propulsion/auxiliary-electric) › Generator Voltage Regulator Circuitry
Issued 13 July 2017
Resolved
CITE: 74 SOLAS (2014) I/II(A) CODE: 1499 ACTION: 40AC
THE COOLANT HOSES ARE LEAKING IN THE EMERGENCY GENERATOR.
Pollution Prevention/Response › Prevention Equipment › Incinerator, Shipboard
Issued 13 July 2017
Resolved
CITE: MARPOL ANNEX VI/16.6.1 CODE: 2199 ACTION: 40AC
EACH INCINERATOR SUBJECT TO THIS PARAGRAPH SHALL BE APPROVED BY THE ADMINISTRATION TAKING INTO ACCOUNT THE STANDARD SPECIFICATION FOR SHIPBOARD INCINERATORS DEVELOPED BY THE ORGANIZATION. THE INCINERATOR FAILED TO IGNITE.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 13 July 2017
Resolved
CITE: 74 SOLAS (01) II-2/2.2.8 CODE: 1499 ACTION: 40AC
THE FOLLOWING BASIC PRINCIPLE UNDERLINE THE REGULATIONS IN THIS CHAPTER HAVING REGARD TO THE TYPE OF SHIPS AND THE POTENTIAL FIRE HAZARD INVOLVED TO MINIMIZE THE POSSIBILITY OF IGNITION. HYDRAULIC SUPPLY LINES IN TOP OF PUMP ROOM ARE LEAKING.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 13 July 2017
Resolved
CITE: 74 SOLAS (2014) I/11(a) CODE: 1820 ACTION: 10C
CONDITION OF SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED SEA W/OUT DANGER TO SHIP OR PERSONS ON BOARD. #3 CARGO PUMP WOULD NOT START.
Engineering › Generator (propulsion/auxiliary-electric) › Auto Transformer Circuitry
Issued 13 July 2017
Resolved
CITE: 74 SOLAS (01) II-2/43.3.1.3 CODE: 1499 ACTION: 10C
WHERE THE EMERGENCY SOURCE OF ELECTRICAL POWER IS A GENERATOR, IT SHALL BE CAPABLE OF BEING AUTOMATICALLY STARTED AND SUPPLYING THE REQUIRED LOAD AS QUICKLY AS IS SAFE AND PRACTICABLE SUBJECT TO A MAXIMUM OF 45 S. THE EMERGENCY GENERATOR WOULD NOT TAKE A LOAD IN 45 SECONDS.
Deck/Cargo › Inert Gas System › IGS Blower
Issued 12 July 2017
Resolved
CITE: 74 SOLAS (2001) II-2/62.7.2 CODE: 1199 ACTION: 60AC
AT LEAST TWO BLOWERS SHALL BE FITTED WHICH TOGETHER SHALL BE CAPABLE OF DELIVERING TO THE CARGO TANKS AT LEAST THE VOLUME OF GAS REQUIRED BY PARAGRAPH 3. THE #2 BLOWER IS INOPERABLE.
Deck/Cargo › Ballast › Vents
Issued 12 July 2017
Resolved
CITE: 74 SOLAS (2014) I/II(a) CODE: 0940 ACTION: 40ac
THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMIAN FIT TO PROCEED TO SEA WITHOU DANGER TO THE SHIP OR PERSONS ON BOARD. #1 STBD BALLAST WATER TANK VENT HAS PUNCTURES BACKSIDE OF TANK UNPROTECTED BY FLAME SCREEN.
Electrical › Electric Generation Source (emergency) › Generator
Issued 14 May 2012
Resolved
74 SOLAS (04 Cons) II-I/44.2: Each emergency generator set shall be equipped with at least two starting devices capable of three consecutive starts each. The emergency generator is unable to start by electronic means and therefor can only be started via hydraulic starting device. (17ac)
Engineering › Diesel Engine (auxiliary) › Valve
Issued 15 February 2011
Resolved
The machinery and associated piping systems and fittings shall be so installed and protected as to reduce to a minimum any danger. #2 ship service generator leaking fuel oil from fitting at aft of engine at a continual drip. Oil pooling on deck below generator.
Lifesaving › Lifeboat › Fire Protection (water spray system)
Issued 19 January 2008
Resolved
Observed soft patch and damage to Portside Lifeboat sprinkler system. Permanent repairs to be completed to the satisfaction of attending Class Surveyor.
Engineering › Diesel Engine (propulsion-direct drive) › Valve
Issued 9 May 2007
Resolved
It has been reported that the vessel has experienced a main engine problem resulting in reduced engine power. Provide class report concerning repairs and attesting to satisfactory operation of main engine prior to departure.
Communications › Radio Communications › VHF Radiotelephone
Issued 5 January 2007
Resolved
One of the two VHF radios located on the bridge is inoperable. Fax tech report to CG when repaired. SOLAS(2004) Ch IV Reg 15.6.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.