Records from 2016 to 2026. Most recent: inspection, 15 July 2026.
Inspection history · 16
15 July 2026
Type not recorded
No type recorded · Station Maui · USCG Oceania District (CGD-O) · Activity 8439261
8 April 2026
Deficiency Check · Drydock Exam · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8344483
4 March 2026
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8355037
21 January 2026
Type not recorded
No type recorded · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8328999
10 June 2025
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Wailuku · USCG Oceania District (CGD-O) · Activity 8156125
9 April 2024
Drydock Exam · COI Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7892174
6 June 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7710211
8 June 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7472109
18 June 2021
Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7227724
3 April 2020
Drydock Exam · Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6935165
16 July 2019
Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6752685
6 June 2019
COI Inspection · Internal Structural Exam · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6706804
24 September 2018
Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6561897
16 April 2018
Annual Inspection · Administrative Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6392945
6 September 2017
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6261872
7 April 2016
Annual Inspection · Administrative Inspection · Hull Examination · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5850269
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 April 2026
Resolved
A dry dock examination must be conducted while the vessel is hauled out of the water or placed in a drydock or slipway. During the examination all accessible parts of the vessel's underwater body and all through hull fittings, appendages, propellers, shafts, bearings, rudders, sea valves, and sea strainers shall be made available for examination. Integrity of vessels collar failed during overpressure stress test pressure test of vessels collar. Vessel plans to swap out with "In -Kind" collar. Provide successful exterior and overpressure leak test with newly installed collar prior to resuming operations with passengers IAW (MTN) 01-08, CH-2. 46 CFR 176.610(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 April 2026
Resolution: New "In-kind" collar installed and tested to the satisfaction of attending Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 April 2024
Resolved
The name of the vessel must be marked on some clearly visible exterior part of the port and starboard bow and the stern of the vessel. No name on port and starboard bow. Provide vessel name on port and starboard bow.
46 CFR 185.602 (a)
46 CFR 67.123 (a)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 April 2024
Resolved 10 May 2024
Resolution: Vessel name painted on bow.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 June 2023
Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. All-around light not showing an unbroken light over an arc of the horizon of 360 degrees. Provide all-around light showing an unbroken light over an arc of the horizon of 360 degrees.
46 CFR 183.420
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2023
Resolved 22 June 2023
Resolution: Nav light provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2023
Resolved
Gauges to indicate engine revolutions per minute (RPM) must be provided. Electronic engine gauges for port engine not operational. Provide operational gauges for port engine.
46 CFR 182.410(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2023
Resolved 17 June 2023
Resolution: Engine gauges operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 June 2023
Resolved
Provision must be made for closing all supply/exhaust cowls for a space protected by a fixed gas extinguishing system. Fuel tank space supply cowls did not close and stay closed. Provide closure device for supply cowls.
46 CFR 182.460
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 June 2023
Resolution: Tie backs used to secure ventilation closure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 June 2022
Resolved
A propulsion engine control system must be designed so that a loss of power to the control system does not result in an increase in shaft speed. Vessel is equipped with a fly-by-wire throttle system, however QFA and DVTP was never provided and test was not completed. Provide QFA and DVTP in accordance with CVC-Policy Letter 17-07 and conduct testing IAW approved QFA and DVTP. 46CFR184.620(c)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 30 August 2022
Resolution: QFA/DVTP provided approved and testing completed.
04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 8 June 2022
Resolved
The owner, charterer, master or managing operator shall instruct each crew member, upon first being employed and prior to getting underway for the first time on a particular vessel and at least once every three months, as to the duties that the crew member is expected to perform in an emergency including, but not limited to, the emergency instructions listed on the emergency instruction placard required by § 185.510 of this part and, when applicable, the duties listed in the station bill required by § 185.514 of this part. The vessel failed to properly record the required drills. Properly document drills. 46CFR185.420(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 5 July 2022
Resolution: Drill logs provided.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 8 June 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. The first-aid kit is missing the required Aspirin. Ensure first-aid kit has all required components. 46CFR184.710
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 5 July 2022
Resolution: Full first aid kit provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 8 June 2022
Resolved
A submersible electric bilge pump may be used as a power bilge pump only on a vessel of not more than 65 feet in length carrying not more than 49 passengers, other than a ferry, provided that the pump is listed by an independent laboratory as meeting the requirements in UL 1113. The vessel’s electric bilge pump is not UL rated. Replace installed bilge pumps with UL rated bilge pumps. 46CFR182.520(e)(1)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 21 June 2022
Resolution: UL rated bilge pumps provided.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 8 June 2022
Resolved
As appropriate for intended voyage, a vessel must carry adequate and up-to-date: Charts, U.S. Coast Pilot [name withheld] List, tide tables, and current tables. The vessels nautical charts are not corrected. Correct outdated charts or replace with current charts. 46CFR184.420
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 July 2022
Resolved 20 June 2022
Resolution: Chart providd.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 8 June 2022
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel failed to complete credit drydock inspection within two years from last drydock inspection. Vessel completed credit drydock inspection. 46CFR176.600(c)(1)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 8 June 2022
Resolved 8 June 2022
Resolution: Conducted Dry dock exam
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 June 2021
Resolved
Vessel name and hailing port sign missing from stern. Provide vessel name and hailing port on stern of vessel.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 19 July 2021
Resolution: Name placed on stern.
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 18 June 2021
Resolved
Hole located in deck in battery space. Repair hole to ensure fuel tank space is vapor tight and Pre-engineered fixed fire fighting system can cover cubic foot coverage area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 10 July 2021
Resolution: Hole patched.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 June 2021
Resolved
Discharge side of blower hose holed. Replace blower hose with new hose.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 10 July 2021
Resolution: New hose provided.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 June 2021
Resolved
Ring buoy line deteriorated. Provide new ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 19 July 2021
Resolution: New ring buoy provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 June 2021
Resolved
Items in first aid kit expired. Ensure all expired items discarded and replaced with valid items.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 19 July 2021
Resolution: First aid kit renewed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 June 2021
Resolved
Supervisory and general crewmember drug awareness training not recorded/conducted. Conduct and record supervisor and general drug awareness training with staff.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 19 July 2021
Resolution: Drug training completed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 18 June 2021
Resolved
Missing blower ignition interlock. Blower switch must be interlocked with the starting switch and the ignition switch so that the blowers are started before the engine started motor circuit or the engine ignition is energized. Provide blower ignition interlock.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2021
Resolved 10 July 2021
Resolution: Ignition interlock provided.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 June 2019
Resolved
Radio Safety Certificate not provided. Provide in accordance with 46 CFR 184.502.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 July 2019
Resolution: Radio Safety Certificate provided.