Records from 2023 to 2025. Most recent: inspection, 2 July 2025.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 November 2023
Resolved
The machinery, boilers and other pressure vessels, associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed jacket water leak on # 3 cylinder on main diesel engine. 74 SOLAS 2004, II-1/26.1, Prior to movement, 60 ac
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 December 2023
Resolution: Recieved, reviewed and accepted Class Report from NKK attesting to the repair to the jacket water on the #3 MDE cylinder
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 November 2023
Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed that ships engineering crew installed plastic sheeting to deflect water from F/W generator that is spraying on BWMS transformer. 74 SOLAS 2004, II-1/45.1.3, Prior to Dep, 17ac
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2023
Resolution: Recieved, reviwed and accepted Class report from NKK attesting to the removal of the plastic shielding.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 30 November 2023
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: Fire detection and fire alarm systems. PSCO observed disabled fire alarm panel on the bridge. 74 SOLAS 2009, II-2/14.2.1.1, 10c
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 30 November 2023
Resolution: Cleared on board during course of exam
11 - Life Saving Appliances › N/A - No Subsystem › Immersion suits
Issued 30 November 2023
Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. PSCO observed immersion suit zipper fouled with cloth. 74 SOLAS 2020, III/20.2, 10c
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 30 November 2023
Resolution: Cleared on board during course of exam
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 30 November 2023
Resolved
Before the ship leaves port and at all times during the voyage, all life saving appliances shall be in working order and ready for immediate use. PSCO observed an inoperable lifebuoy light. 74 SOLAS 2020, III/20.2, 10c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 30 November 2023
Resolution: Cleared on board during course of exam
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 30 November 2023
No resolution recorded
PSCO observed vessel had no oil transfer procedures on board. 33 cfr 155.720, Prior to next US port, 40c
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign