MAURY USCG vessel records
← All vessels

COASTAL EXPLORER

COASTAL EXPLORER is a 2013 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in September 2025, along with 23 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 24 September 2025.

Built
2013
Last inspected
24 September 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDG9455
1251550
Flag
UNITED STATES
Maury page id
psix-1251550

Inspections, by type

Years with a record 9 calendar years (2016–2025)
The 20 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)48.4 ft × 17.7 ft × 8.3 ft
Registered tonnagegross 26 / net 21
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderARMSTRONG MARINE INC · PORT ANGELES, WA, UNITED STATES · built 2013
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationTwin Hull
Hailing portNORTH MYRTLE BEACH, SC
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 17 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it21 - Simplified, Net Ton
26 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 20

24 September 2025 COI Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8237293
1 July 2025 Internal Structural Exam · In-Service Inspection · Drydock Exam · Examination of Repairs
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 8172663
28 January 2025 Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8074600
4 October 2023 Drydock Exam · COI Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7805193
21 March 2023 Plan Review "T" Boat
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 7654141
21 September 2022 Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7563895
15 October 2021 Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7333283
1 July 2021 Internal Structural Exam · Examination of Repairs · Hull Examination · Deficiency Check · Drydock Exam
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7239484
12 October 2020 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7072554
24 January 2020 Plan Review "T" Boat · Administrative Inspection
Administrative · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6901799
26 June 2019 Deficiency Check · Drydock Exam · Internal Structural Exam · COI Inspection · Hull Examination · Administrative Inspection · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6717745
15 August 2018 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6506856
25 October 2017 Administrative Inspection
Administrative · Navigation Center · Activity 6294767
4 October 2017 Deficiency Check
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6281358
18 September 2017 DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6267091
21 July 2017 Drydock Exam · Hull Examination · Deficiency Check · Internal Structural Exam · Examination of Repairs
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6215096
13 October 2016 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6021842
15 August 2016 Examination of Repairs
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 5973032
22 June 2016 In-Service Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5915781
9 June 2016 In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5902160

Deficiency record · 23

02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 15 April 2025 Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. The OCMI may also decrease the drydock examination intervals to monitor the vessel's structural condition. Port and starboard propeller tunnels have wastage and pitting in excess of allowable tolerances. Crop and renew hull plating IWO the hull tunnels to good metal, approximately 5' by 3' as discussed with the vessel reps at the inspection, prior to carrying passengers.
Action required: 705 - Other - as specified
Resolved 21 August 2025
Resolution: Repairs made to the hull IWO both propeller tunnels.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2021 Resolved
All accessible parts of the vessels underwater body to include propellors, shafts, bearings, and appendages shall be examined during drydock inspection. Attending Inspector(s) identified fractured weldments IWO starboard (aft) strut assembly.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2021
Resolved 30 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 July 2021 Resolved
All accessible parts of the vessels underwater body to include hull plating, sea chests, and sea valves shall be examined during drydock inspection. Attending Inspector(s) noted that the threads for the port main diesel engine through hull valve were not adequate (cut to short).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 August 2021
Resolved 30 September 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 June 2019 Resolved
Port main diesel engine exhuast support/bracket is fractured IWO exhaust piping.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 24 February 2020
Resolution: Attending Inspector verified repairs made to port/starboard main diesel engine exhaust support brackets.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 26 June 2019 Resolved
FCC Radio Safety-Telephony Certificate expired.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 July 2019
Resolved 17 July 2019
Resolution: Attending Inspector(s) verified renewal of FCC Radio Safety Telephony Certificate
Documentation › Markings/Placards › Warning Signs
Issued 18 September 2017 Resolved
Emergency escapes were not marked properly.
Action required: 705 - Other - as specified
Due 18 October 2017
Resolved 4 October 2017
Resolution: Attending Inspectors verified markings for emergency escapes.
Documentation › Markings/Placards › Warning Signs
Issued 18 September 2017 Resolved
Watertight hatch markings were missing.
Action required: 705 - Other - as specified
Due 18 October 2017
Resolved 4 October 2017
Resolution: Attending Inspectors verified watertight hatch markings.
Communications › Radio Communications › VHF Radiotelephone
Issued 18 September 2017 Resolved
VHF radiotelephones were not programmed with MMSI (DSC equipped).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 October 2017
Resolved 4 October 2017
Resolution: Attending Inspector verified programming of VHF-FM marine radio-telephone (MMSI #)
Fire Fighting › Remote Fuel Shutoff › General
Issued 18 September 2017 Resolved
Emergency fuel shutoff valve for diesel heater (starboard bridge wing) was not properly marked.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 October 2017
Resolved 4 October 2017
Resolution: Attending Inspectors verified markings/operating instructions for emergency fuel shut off valve for bridge heater tank/piping.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 18 September 2017 Resolved
Vessels navigation publications were not current/up to date; i.e.: CG Light List, Tidal Tables, Tidal Current Tables, Coast Pilot.
Action required: 705 - Other - as specified
Due 18 October 2017
Resolved 4 October 2017
Resolution: Attending Inspectors verified carriage of current/up to date navigational publications for areas transited.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 September 2017 Resolved
Rescue line was subleached (UV) and required replacement.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 October 2017
Resolved 4 October 2017
Resolution: Attending Inspectors verified renewal of rescue line for ring buoy.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 21 July 2017 Resolved
Exhaust supports/brackets for port & starboard main diesel engines were fractured.
Action required: 705 - Other - as specified
Due 7 August 2017
Resolved 9 August 2017
Resolution: Attending Inspector(s) verified repairs made in way of port/starboard main engine exhaust brackets.
Construction/Loadline › Hull › Weld
Issued 21 July 2017 Resolved
Fractured weldment in way of starboard swim platform mountings.
Action required: 705 - Other - as specified
Due 7 August 2017
Resolved 9 August 2017
Resolution: Attending Inspector(s) verified with local welder that no fracture was present.
Engineering › Sea-water System (primary cooling) › Piping
Issued 21 July 2017 Resolved
Owner/operator is requesting to renew starboard thru-hull valve in way of machinery space due to the orientation of the valve handle.
Action required: 705 - Other - as specified
Due 7 August 2017
Resolved 9 August 2017
Resolution: Attending Inspector(s) verified the installation of a new thru-hull fitting in way of starboard machinery space and performed operational test.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 20 October 2016 Resolved
D.O.T. approved alcohol testing equipment was expired/outdated.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2016
Resolved 22 November 2016
Resolution: Attending Inspector verified carriage of current/up to date D.O.T. testing equipment.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 October 2016 Resolved
Expired/outdated items in first aid kit.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2016
Resolved 19 January 2017
Resolution: Attending Inspector verified contents of new first aid kit.
Lifesaving › Hand Flares › Expired
Issued 20 October 2016 Resolved
Visual distress signals expired.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2016
Resolved 22 November 2016
Resolution: Attending Inspector verified carriage of proper type/qty of visual distress signals.
Navigation › Piloting/Steering › Marine Charts
Issued 20 October 2016 Resolved
Vessel did not have current/up to date marine charts for areas transited.
Action required: 705 - Other - as specified
Due 19 November 2016
Resolved 22 November 2016
Resolution: Attending Inspector verified carriage of current/up to date marine charts for areas transited.
Navigation › Piloting/Steering › US Coast Pilot
Issued 20 October 2016 Resolved
Vessel did not carry current/up to date navigation publications, i.e.: Coast Pilot, Tide/Current Tables, USCG Light List....
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2016
Resolved 22 November 2016
Resolution: Attending Inspector verified carriage of current/up to date navigation publications.
Fire Fighting › Ventilation Systems › Ventilation Fire Dampers
Issued 20 October 2016 Resolved
Fire dampers for machinery space required servicing & re-testing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2016
Resolved 22 November 2016
Resolution: Attending Inspector verified operation of aft fire dampers, test sat.
Fire Fighting › Remote Fuel Shutoff › General
Issued 20 October 2016 Resolved
Missing instructions (operation) for emergency fuel shut-off valves.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2016
Resolved 22 November 2016
Resolution: Attending Inspector verified markings/operating instructions for emergency fuel shut-off valves.
Stability › Watertight Integrity › General
Issued 20 October 2016 Resolved
Vessels thru-hull fittings were missing double hose clamps @ side shell.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 19 November 2016
Resolved 22 November 2016
Resolution: Attending Inspector verified installation of double-hose clamps IWO starboard sponson.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 20 October 2016 Resolved
Vessel was unable to conduct required drills during initial inspection.
Action required: 705 - Other - as specified
Due 19 November 2016
Resolved 22 November 2016
Resolution: Attending Inspectors performed u/w drills with vessels crew to include fire & man overboard.

Ownership record