MAURY USCG vessel records Sign in
← All vessels

SHIN HO CHUN NO. 101

SHIN HO CHUN NO. 101 is a 1999 freight ship. The Coast Guard has recorded 3 inspections since 2000, most recently in February 2008, along with 66 deficiencies and 1 operational control.

Records from 2000 to 2008. Most recent: inspection, 6 February 2008.

Built
1999
Last inspected
6 February 2008
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9220653 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
Flag
KIRIBATI
—
Maury page id
psix-12538

Inspections, by type

…with no type recorded2
Years with a record 2 calendar years (2000–2008)
The 3 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 18 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Refrigerated Cargo Ship class in Maury's sources begin in 1984.

Documentation record

Tonnage as PSIX records it1108 - Regulatory (Subpart C or D), Net Ton
2495 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 3

6 February 2008 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 3143166
23 January 2008 Deficiency Check · PII Safety Exam · MARPOL Annex I Examination · ISPS II Exam
Physical examination · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 3135317
31 July 2000 Type not recorded
No type recorded · Marine Safety Detachment American Samoa · USCG Oceania District (CGD-O) · Activity 280559

Deficiency record · 66

Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 23 January 2008 Resolved
The OWS is not operating in accordance with MARPOL includingn allowing oily water discharge past the 3 way valve overboard when the Oil [name withheld] indicates 30 ppm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 February 2008
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 23 January 2008 Resolved
The sludge pumping system arrangement has unauthorized valve and rubber hose arrangement on the discharge side of the sludge pump which connects to the MDE saltwater cooling overboard discharge piping. This unauthorized arrangement allows oil sludges to by pass the OWS and be discharged directly overboard.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 11 February 2008
Documentation › Logs/Records › Oil Record Book
Issued 23 January 2008 Resolved
Found oil record book entries not in compliance with MARPOL.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 February 2008
Fire Fighting › Fire Main › Pressure
Issued 23 January 2008 Resolved
Main fire pumps unable to provide adequate water supply.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 February 2008
Fire Fighting › Emergency Fire Pumps › Pressure
Issued 23 January 2008 Resolved
Emergency fire pump unable to provide adequate water supply.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 February 2008
Fire Fighting › Fire Hoses › Condition
Issued 23 January 2008 Resolved
Found all fire hoses in poor condition, jackets holed, with multiple leaks.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 February 2008
Fire Fighting › Fire Hoses › Number
Issued 23 January 2008 Resolved
The engine room lacks a sufficient number of fire hoses.
Action required: 705 - Other - as specified
Resolved 11 February 2008
Fire Fighting › Structural - Main Vertical Zones › General
Issued 23 January 2008 Resolved
Found inoperative engine room fire dampers in engine room funnel and behind the bridge.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 23 January 2008 Resolved
Found non-approved hold-backs on fire doors.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 23 January 2008 Resolved
Non-conductive matting is missing from the front and back Main switchboard.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 23 January 2008 Resolved
Non-conducting matting is missing from the front and back of the Emergency electrical switchboard.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Accommodation/Occupational Safety › Potable Water System › General
Issued 23 January 2008 Resolved
No potable hot water available in the Galley.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Fire Fighting › Ventilation Systems › Ducts
Issued 23 January 2008 Resolved
Found hazardous condition from excessive grease in galley ventilation ducts.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Electrical › Electrical Distribution System (service) › Panelboard
Issued 23 January 2008 Resolved
An electrical panel located in the galley is missing a cover.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 23 January 2008 Resolved
Found missing emergency egress latch opener in reefer flat door.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Communications › Alarms/Indicators › Refrigerated Spaces Alarm System
Issued 23 January 2008 Resolved
Alarm in reefer flat can oly be heard in the immediate vicinity.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Accommodation/Occupational Safety › Washroom/Toilet › Shower/Bathtub
Issued 23 January 2008 Resolved
Found exposed electrical wires inside the crew's common shower area.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Accommodation/Occupational Safety › Washroom/Toilet › Location
Issued 23 January 2008 Resolved
Found no toilet facilities available in or near the hospital space.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 February 2008
Accommodation/Occupational Safety › Medical/First Aid › Hospital Space
Issued 23 January 2008 Resolved
The hospital space is being used for storage and as a computer workstation.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 23 January 2008 Resolved
Steering gear compartment not in compliance with slippage requirements due to lack of handrails, grating or other non-slip surfaces.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Stability › Watertight Integrity › General
Issued 23 January 2008 Resolved
Found watertight and weathertight doors not in compliance ICCL due to misaligned hinges, worn knife edges and worn or missing gaskets.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Operations/Management › Pollution › Control of Garbage
Issued 23 January 2008 Resolved
There is no MARPOL V garbage placard on the mess deck, lounge or galley.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 February 2008
Navigation › Piloting/Steering › Magnetic Compass
Issued 23 January 2008 Resolved
The magnetic compass is not capable of illumination.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 February 2008
Navigation › Piloting/Steering › Marine Charts
Issued 23 January 2008 Resolved
The vessel is missing current or corrected American Samoa charts.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 23 January 2008 Resolved
There is no warning statement on the maneuvering fact sheet.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Lifesaving › Rocket Parachute Flares › General
Issued 23 January 2008 Resolved
The vessel is missing 2 parachute flares.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Navigation › Piloting/Steering › Gyro Compass
Issued 23 January 2008 Resolved
Found inoperative gyro including starboard gyro repeater reading is 116 degrees different than the master gyro.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Lifesaving › Lifebuoys › Stowage
Issued 23 January 2008 Resolved
Found port and stbd bridge ring buoys installed improperly which restricts free fall of the ring buoy.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Operations/Management › Drills/Instruction › Fire
Issued 23 January 2008 Resolved
Both fire fighting ensembles are located in the same area.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 11 February 2008
Communications › Internal Communications System › Sound-powered Telephone
Issued 23 January 2008 Resolved
No communication exists between the bridge and steering compartment.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Fire Fighting › Self-contained Breathing Apparatus › Air Supply (minutes)
Issued 23 January 2008 Resolved
First SCBA mask will not provide air.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 11 February 2008
Fire Fighting › Firemans Outfit › Self-Contained Breathing Apparatus
Issued 23 January 2008 Resolved
Second SCBA mask has broken strap and internal parts are coming apart.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Fire Fighting › Self-contained Breathing Apparatus › Air Bottle, Spare
Issued 23 January 2008 Resolved
Vessel is missing one of the two required spare charges (SCBA bottles) for the fire-fighter's outfits.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 11 February 2008
Electrical
Issued 31 July 2000 Resolved
Prove proper operation of emergency lighting system.
Condition: Unknown
Due 22 November 2000
Resolved 22 November 2000
Fire Fighting
Issued 31 July 2000 Resolved
Conduct fire drill to the satisfaction of attending Coast Guard Marine Inspector IAW SOLAS 74 (amended) III/53.
Condition: Unknown
Due 1 August 2000
Resolved 22 November 2000
Fire Fighting
Issued 31 July 2000 Resolved
Provide 2 SCBA bottles and 2 spare SCBA bottles with air IAW SOLAS 74 (amended) II-2/17.1.2.
Condition: Unknown
Due 1 August 2000
Resolved 22 November 2000
Lifesaving
Issued 31 July 2000 Resolved
Provide 12 rocket parachute flares IAW SOLAS 74 (amended) III/63.
Condition: Unknown
Due 1 August 2000
Resolved 22 November 2000
Documentation
Issued 31 July 2000 Resolved
Provide evidence of Coast Guard approval or IMO type approval certificationby a Flag State party to MARPOL for installed MSD IAW 33 CFR 159.7.
Condition: Unknown
Due 1 August 2000
Resolved 22 November 2000
Lifesaving › Rescue Boat › Carriage Requirement
Issued 31 July 2000 Resolved
Be able to prepare the rescue boat to be launched in less than 5 minutes IAW SOLAS 74 (amended) III/14.1.
Condition: Unknown
Due 1 August 2000
Resolved 11 February 2008
Lifesaving › Rescue Boat › Carriage Requirement
Issued 31 July 2000 Resolved
Provide SOLAS training manual IAW SOLAS 74 (amended) III/51.
Condition: Unknown
Due 31 August 2000
Resolved 11 February 2008
Fire Fighting › Miscellaneous Items › A Class Division Penetrations
Issued 31 July 2000 Resolved
Provide fire fighting maintenance and operation manual IAW SOLAS 74 (amended) II-2/20.1.
Condition: Unknown
Due 31 August 2000
Resolved 11 February 2008
Lifesaving › Rescue Boat › Carriage Requirement
Issued 31 July 2000 Resolved
Provide lifesaving maintenance manual IAW SOLAS 74 (amended) III/52.
Condition: Unknown
Due 31 August 2000
Resolved 11 February 2008
Navigation
Issued 31 July 2000 Resolved
Provide current deviation table for magnetic compass IAW 33 CFR 164.35(c).
Condition: Unknown
Due 31 August 2000
Resolved 22 November 2000
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 31 July 2000 Resolved
Provide maneurving fact sheet IAW 33 CFR 164.35(g)(1).
Condition: Unknown
Due 31 August 2000
Resolved 11 February 2008
Documentation
Issued 31 July 2000 Resolved
Provide oil transfer procedures IAW 33 CFR 155.720.
Condition: Unknown
Due 31 August 2000
Resolved 22 November 2000
Navigation › Piloting/Steering › Maneuvering Information Fact Sheet
Issued 31 July 2000 Resolved
Log pre-arrival test IAW 33 CFR 164.25.
Condition: Unknown
Due 31 August 2000
Resolved 11 February 2008
Lifesaving
Issued 31 July 2000 Resolved
Provide lights for lifebuoys IAW SOLAS 74 (amended) III/7.1.3.
Condition: Unknown
Due 1 August 2000
Resolved 22 November 2000
Electrical
Issued 31 July 2000 Resolved
Provide permanent wiring for freezer in steering space IAW SOLAS 74 (amended) II-1/45.
Condition: Unknown
Due 31 August 2000
Resolved 22 November 2000
Documentation
Issued 31 July 2000 Resolved
Provide Flag State approval for SOPEP IAW 33 CFR 151.29.
Condition: Unknown
Due 1 August 2000
Resolved 22 November 2000
Documentation
Issued 31 July 2000 Resolved
Provide valid STCW certificates of competencies for all officers IAW STCW 95 Article X.
Condition: Unknown
Due 1 August 2000
Resolved 22 November 2000
Accommodation/Occupational Safety
Issued 31 July 2000 Resolved
Provide grease trap for galley ventillation IAW SOLAS 74 (amended) II-2/18.7.
Condition: Unknown
Due 31 August 2000
Resolved 22 November 2000
Engineering › Fuel Oil Service System › Vent Pipe
Issued 31 July 2000 Resolved
Provide fuel vent containment of at least 1/2 barrel IAW 33 CFR 155.320.
Condition: Unknown
Due 31 August 2000
Resolved 11 February 2008
Accommodation/Occupational Safety
Issued 31 July 2000 Resolved
Provide hospital space IAW ILO 147.
Condition: Unknown
Due 1 August 2000
Resolved 22 November 2000
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 31 July 2000 Resolved
Provide fixed fire fighting system in paint locker IAW SOLAS 74 (amended) II-2/18.7.
Condition: Unknown
Due 31 August 2000
Resolved 11 February 2008
Accommodation/Occupational Safety › Refrigeration (stores) › General
Issued 31 July 2000 Resolved
Provide alarm for provisions stores (reefer spaces) in case someone is locked inside IAW ILO 147.
Condition: Unknown
Due 31 August 2000
Resolved 11 February 2008
Accommodation/Occupational Safety › Occupational Safety › Hand Grab
Issued 31 July 2000 Resolved
Provide handrails on all stairways IAW ILO 147.
Condition: Unknown
Due 31 August 2000
Resolved 11 February 2008
Lifesaving › Lifebuoys › Self-Activitating Smoke Signals
Issued 31 July 2000 Resolved
Provide smoke signals for quick releaseing lifebuoys IAW SOLAS 74 (amended)III/71.3.
Condition: Unknown
Due 1 August 2000
Resolved 11 February 2008
Lifesaving › Emergency Outfit › Protective Clothing
Issued 31 July 2000 Resolved
Maintain record of drills IAW SOLAS 74 (amended) III/18.5.
Condition: Unknown
Due 31 August 2000
Resolved 11 February 2008
Lifesaving › Lifeboat › Embarkation/Disembarkation Capabilities
Issued 31 July 2000 Resolved
Launch free-fall lifeboat prior to return to U.S. waters IAW SOLAS 74 (amended) III/18.3.7.
Condition: Unknown
Due 31 August 2000
Resolved 11 February 2008
Electrical › Lighting (emergency) › Lighting Fixture
Issued 31 July 2000 Resolved
Provide class report accepting the installation of emergency lights for lifeboat embarkation.
Condition: Unknown
Due 1 October 2000
Resolved 11 February 2008
Electrical › Electrical Distribution System (emergency) › Wiring
Issued 31 July 2000 Resolved
Remove splices on cable to lifeboat embarkation light.
Condition: Unknown
Due 1 October 2000
Resolved 11 February 2008
Fire Fighting
Issued 31 July 2000 Resolved
Provide fire doors for stairways IAW SOLAS 74 (amended) II-2/46.
Condition: Unknown
Due 1 August 2000
Resolved 22 November 2000
Fire Fighting
Issued 31 July 2000 Resolved
Provide proper operation of emergency fire pump IAW SOLAS 74 (amended) II-2/3.3
Condition: Unknown
Due 1 August 2000
Resolved 22 November 2000
Lifesaving
Issued 31 July 2000 Resolved
Install lighting at lifeboat embarkation deck that operable form emergency circuit IAW SOLAS 74 (amended) II-1/43.2.1.
Condition: Unknown
Due 1 August 2000
Resolved 22 November 2000
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 31 July 2000 Resolved
Provide fire doors in stairwells without louvers.
Condition: Unknown
Due 1 October 2000
Resolved 11 February 2008
Lifesaving › Launching Appliances › Davit
Issued 31 July 2000 Resolved
Provide davit launched liferaft. (vessel has free-fall lifeboat)
Condition: Unknown
Due 1 October 2000
Resolved 11 February 2008

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.