SOUTH VENICE BEACH FERRY is a 2014 passenger vessel (inspected). The Coast Guard has recorded 16 inspections since 2016, most recently in March 2025, along with 13 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 22 March 2025.

Built
2014
Last inspected
22 March 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

1254749
Flag
UNITED STATES
Maury page id
psix-1254749

Inspections, by type

…with no type recorded1
Years with a record 10 calendar years (2016–2025)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it3 - Simplified, Net Ton
3 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 16

22 March 2025 Type not recorded
No type recorded · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8099551
19 March 2025 COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8095090
17 July 2024 Hull Examination · Annual Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7958601
3 July 2023 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7726152
18 October 2022 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7579883
6 July 2022 Internal Structural Exam · Annual Inspection · Drydock Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7497148
23 June 2021 Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7232817
22 July 2020 Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7008625
12 May 2020 Administrative Inspection · COI Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6951788
26 June 2019 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6723774
15 August 2018 Examination of Repairs · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6511380
11 July 2018 Administrative Inspection · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6474148
14 June 2017 DAPI Audit · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6169206
24 August 2016 Deficiency Check · Administrative Inspection · Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5980539
17 May 2016 Administrative Inspection · Plan Review "T" Boat · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5857543
15 January 2016 Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5798004

Deficiency record · 13

09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 17 July 2024 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. The first aid kit contains expired contents. Renew first aid kit contents. 46CFR184.710
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 19 July 2024
Resolution: A vessel now carries a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10).
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 3 July 2023 Resolved
Life ring line was corroded beyond serviceable condition. Replace in kind to satisfaction of attending marine inspector. 46 CFR 180.70(c)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2023
Resolved 11 July 2023
Resolution: Life ring line was replaced in kind.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 3 July 2023 Resolved
Adult and child life jackets are stowed in unlabeled bags. Label bags to differentiate adult and child life jackets. 46 CFR 180.78(a)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2023
Resolved 11 July 2023
Resolution: Labels for the life jackets were re stenciled.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 July 2023 Resolved
No emergency procedures are posted in accordance with 46 CFR 185.510. Create and post emergency procedures in vicinity of the operating station. 46 CFR 185.510
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2023
Resolved 11 July 2023
Resolution: Emergency procedures were printed/laminated and posted at operating station.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 July 2023 Resolved
Alcohol testing devices are expired. Replace with valid test kits. 46 CFR 4.06-15
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 July 2023
Resolved 11 July 2023
Resolution: New alcohol test strips recieved from consortium.
Operations/Management › Casualty Reporting/Post-Casualty Actions › Determination of Alcohol/Drug Use
Issued 14 June 2017 Resolved
Provid new alcohol testing kits to replace expired ones. (46CFR4.06)
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 19 June 2017
Resolution: Purchased new test kits.
Lifesaving › Work Vest › Quantity
Issued 14 June 2017 Resolved
Provide crew life vest for master to wear during man overboard. (46CFR180.72(c)
Action required: 705 - Other - as specified
Due 28 June 2017
Resolved 19 June 2017
Resolution: Purchased work vest for MOB recovery.
Construction/Loadline › Hull › Side Shell
Issued 24 August 2016 Resolved
Gel coat to catamaran hulls worn away above waterline port / starboard sides - repair all marked areas.
Action required: 705 - Other - as specified
Due 24 September 2016
Resolved 31 October 2016
Resolution: Repairs complete.
Construction/Loadline › Hull › Side Shell
Issued 24 August 2016 Resolved
Paint along bottoms of catamaran hulls worn down to gel coat - paint / repair.
Action required: 705 - Other - as specified
Due 24 September 2016
Resolved 31 October 2016
Resolution: Repairs complete.
Construction/Loadline › Structures › Deck Plating
Issued 24 August 2016 Resolved
Voluntary deck renewal scheduled (O/O dissatisfied w/ plywood deck , will be changing) Will replace under non-credit drydock starting 01SEP16. Submit proposal to DD Ft Myers.
Action required: 705 - Other - as specified
Resolved 31 October 2016
Resolution: Repairs complete.
Construction/Loadline › Structures › Deck Plating
Issued 17 May 2016 Resolved
Make permanent repairs to area identified on the main deck, IAW 46 CFR 176.610
Action required: 705 - Other - as specified
Due 17 June 2016
Resolved 24 August 2016
Resolution: Deck repairs to plywood deck with FRP overcoat completed.
Electrical › Electric Supply System (service) › Cable
Issued 17 May 2016 Resolved
Provide copy of MSC Approved drawings to the Coast Guard for electrical system. Make changes to electrical drawings to reflect the current electrical system and submit to MSC for approval, IAW 46 CFR 177.202(b)(4).
Action required: 705 - Other - as specified
Due 3 June 2016
Resolved 29 September 2016
Resolution: Updated drawing submitted to DD-FT Myers for Approval. Forwarded to SSP for approval. SSP approved drawings and submitted approval letter for electrical drawings. Deficiency cleared.
Operations/Management › Drills/Instruction › Not Conducted
Issued 17 May 2016 Resolved
Document/Log all man overboard and fire drills for review by the attending marine inspector, IAW 46 CFR 185.520 & 524.
Action required: 705 - Other - as specified
Due 17 May 2016
Resolved 17 May 2016
Resolution: Corrected on the spot.

Ownership record