Records from 2014 to 2025. Most recent: inspection, 6 November 2025.
Documentation record
Registered dimensions (L × B × D)34.0 ft × 12.0 ft × 3.0 ft
Registered tonnagegross 5 / net 5
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCORINTHIAN CATAMARANS LLC · TARPON SPRINGS, FL, UNITED STATES · built 2013
Hull materialFRP (Fiberglass)
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portUSEPPA ISLAND, FL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5 - Simplified, Net Ton
5 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
6 November 2025
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8264713
21 August 2025
Internal Structural Exam · Drydock Exam · Hull Examination · Examination of Repairs · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8212380
28 October 2024
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 8024783
25 July 2023
Internal Structural Exam · Hull Examination · COI Inspection · Deficiency Check
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7750825
7 November 2022
Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7588013
26 October 2022
Administrative Inspection
Administrative · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7584208
21 October 2021
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7336222
5 August 2021
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7276936
6 October 2020
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 7071514
30 October 2019
Annual Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6841881
1 August 2019
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6744482
23 August 2018
COI Inspection · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6519873
7 November 2017
Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6300188
24 August 2017
Hull Examination · Examination of Repairs · Administrative Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6243456
4 November 2016
DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 6023749
1 October 2015
DAPI Audit · Annual Inspection
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5233833
19 August 2015
Hull Examination
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 5202081
29 October 2014
Annual Inspection · DAPI Audit
Physical examination · Detached Duty Office Fort Myers · USCG Southeast District (CGD-SE) · Activity 4997492
02 - Structural Conditions › N/A - No Subsystem › Marking of IMO number
Issued 1 August 2023
Resolved
The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel.
No hailing port is marked on the vessels stern.
46 CFR 67.123
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2023
Resolved 10 August 2023
Resolution: The hailing port of the vessel is now marked and clearly visible exterior part of the stern of the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 August 2023
Resolved
Each ring life buoy must be marked with Type II
retroreflective material approved in accordance with 46
CFR 164.018.
Retroreflective material on life buoy is not in serviceable condition.
46 CFR 185.604
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2023
Resolved 10 August 2023
Resolution: The ring life buoy is marked with Type II retroreflective material approved in accordance with 46 CFR
02 - Structural Conditions › N/A - No Subsystem › Ballast, fuel and other tanks
Issued 1 August 2023
Resolved
The discharge ends of fuel tank vent pipes must be
fitted with removable flame screens or flame arresters.
The flame screens must consist of a single screen of
corrosion resistant wire of at least 30 × 30 mesh. The
flame screens or flame arresters must be of such size
and design as to prevent reduction in the net cross
sectional area of the vent pipe and permit cleaning or
renewal of the flame screens or arrester elements.
Flame screens are not installed on discharge vent of fuel tank.
46 CFR 182.450
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 August 2023
Resolved 15 August 2023
Resolution: Fuel tank vent pipes now have flame screens installed.
Construction/Loadline › Hull › Bottom Plating
Issued 24 August 2017
Resolved
Repair gel coat blisters on hull and refinsih gel coat (46CFR176.610).
Action required: 705 - Other - as specified
Resolved 28 August 2017
Resolution: Sanded down and repaired gel coat blister areas to new.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 1 October 2015
Resolved
Certificate of Documentation was expired as of August 31, 2015. Provide valid current Certificate of Documentation. 46 CFR 67.7
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 October 2015
Resolved 5 October 2015
Resolution: Verified Certificate of Documentation was valid through MISLE.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 1 October 2015
Resolved
Navigation chart for area of operation was out of date. Provide valid current/corrected navigation chart for area of operations. 46 CFR 184.420
Condition: Invalid
Action required: 705 - Other - as specified
Due 1 November 2015
Resolved 8 October 2015
Resolution: Vessel provided a valid currently corrected navigation chart for area of operations.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 October 2014
Resolved
Stern light was not operable. Owner instructed to repair or replace prior to operating at night or in restricted visibility.
Action required: 705 - Other - as specified
Resolved 6 November 2014
Resolution: Stern light repaired. Picture emailed to DD Fort Myers demonstrating operation.
Construction/Loadline › Structures › Door
Issued 29 October 2014
Resolved
An aluminum frame sliding door was installed forward of the operating station without CG approval. Owner instructed to submit plans and re-verify stability calculations.
Due 12 November 2014
Resolved 6 November 2014
Resolution: Owner submitted plans and is working with manufacturer and MSC to verify stability calculations.
Documentation › Markings/Placards › Official Number (US)
Issued 29 October 2014
Resolved
Official number was hand written in permenant marker. Owner/operator was instructed to permenantely affix official number in accordance with 46 CFR 67.121.
Due 12 November 2014
Resolved 3 November 2014
Resolution: Owner/operator emailed a picture to DD Fort Myers of the vessel''s official number permenantely affixed in accordance with 46 CFR 67.121
Engineering › Fuel Oil Service System › Ventilation
Issued 29 October 2014
Resolved
The starboard fuel tank's goose neck vent was damaged durring maintenance. Owner/operator was instructed to submit a plan to repair or replace the gooseneck.
Due 12 November 2014
Resolved 6 November 2014
Resolution: Owner submitted plans to replace the damaged fuel tank.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 29 October 2014
Resolved
Vessels starboard fuel tank will be replaced due to gooseneck being damaged. Vessel submitted plans to replace fuel tank. Once fuel tank replaced local CG Marine Inspector verify proper installation and operation. Operator shall notify CG once tank is in place.
Condition: Damaged By Earlier Event
Due 5 January 2015
Resolved 5 January 2015
Resolution: New tank was installed.