MAURY USCG vessel records
← All vessels

INSANE

INSANE is a 2013 passenger vessel (inspected). The Coast Guard has recorded 15 inspections since 2017, most recently in August 2023, along with 21 deficiencies and 2 casualty investigations between 2019 and 2023.

Records from 2017 to 2023. Most recent: inspection, 9 August 2023.

Built
2013
Last inspected
9 August 2023
Documentation
Expired · documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

WDH3061
1255493
Flag
UNITED STATES
Maury page id
psix-1255493

Inspections, by type

…with no type recorded2
Years with a record 6 calendar years (2017–2023)
The 15 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Registered dimensions (L × B × D)30.0 ft × 10.4 ft × 5.7 ft
Registered tonnagegross 11 / net 9
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSMOKY MOUNTAIN JET BOAT BUILDING LLC · Bryson City, NC, UNITED STATES · built 2013
Hull materialAluminum
PropulsionJet Drive
Hull shapeShip
Hull configurationMonohull
Hailing portLAHAINA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 7 November 2013
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Net Ton
11 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 15

9 August 2023 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7770012
9 August 2023 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7792469
7 February 2023 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7633407
20 December 2021 Deficiency Check · Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7371687
3 December 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7105356
30 December 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6880820
9 December 2019 Administrative Inspection · Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6870669
19 July 2019 Type not recorded
No type recorded · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6755383
17 April 2019 Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6664103
14 December 2018 Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6597543
4 December 2018 Administrative Inspection · DAPI Audit · COI Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6592393
14 March 2018 Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6372044
22 February 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6359945
29 December 2017 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6330430
17 March 2017 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6117233

Deficiency record · 21

11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 7 February 2023 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems, including the following: Inspection of each hydrostatic release unit to determine that it is in compliance with the servicing and usage requirements of 185.740 of this chapter. Hydrostatic release for EPIRB expired. Install new hydrostatic release. 46 CFR 176.808(a)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 February 2023
Resolution: New hydrostatic release provided.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 7 February 2023 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspection of lifesaving equipment and systems, including the following: Inspection of each hydrostatic release unit to determine that it is in compliance with the servicing and usage requirements of 185.740 of this chapter. Hydrostatic release for Life Raft expired. Install new hydrostatic release. 46 CFR 176.808(a)(5)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 17 February 2023
Resolution: New hydrostatic release provided.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 7 February 2023 Resolved
Firefighting, man overboard, and abandon ship drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information: Date of the drill and training; and general description of the drill scenario and training topics. Vessel unable to provide logs for fire fighting, man overboard and abandon ship drills and training. Provide drill logs. 46CFR185.524(d) 46CFR185.520(f)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2023
Resolved 17 February 2023
Resolution: Logbook provided.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 7 February 2023 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked "First-Aid Kit". A first-aid kit must be easily visible and readily available to the crew. First aid kit is incomplete. Provide USCG-approved kit or a kit that complies with the list in 46 CFR 160.041. 46 CFR 184.710
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 March 2023
Resolved 17 February 2023
Resolution: First aid kit provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 20 December 2021 Resolved
A pre-engineered fixed firefighting system must automatically shut down all engines. Fireboy system did not shut down port engine. Provide automatic engine shutdown for pre-engineed fixed firefighting system. 46 CFR 181.420
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 December 2021
Resolution: FIreboy fully operational.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 December 2021 Resolved
Each child life jacket must be marked with Type 1 retro-reflective material. Child life jackets retro-reflective material faded and not working. Provide new retro-reflective material for child life jackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2022
Resolved 27 December 2021
Resolution: Retro tape provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 20 December 2021 Resolved
Gauge for oil pressure must be provided at operating station. Oil pressure gauge for starboard side engine was not working. Provide operational oil pressure gauge.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 January 2022
Resolved 27 December 2021
Resolution: Gauge operational.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 3 December 2020 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of 47 CFR 80.1101(c)(2). Vessel did not have functioning VHF-DSC capable radio. Provide functioning VHF-DSC capable radio.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 January 2021
Resolved 22 December 2020
Resolution: New radio with DSC capability installed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 9 December 2019 Resolved
Inflatable buoyant apparatus painter was fixed to vessel vice weak link. Install in accordance with 46 CFR 180.137.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 December 2019
Resolved 9 December 2019
Resolution: Painter fixed to weak link.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 December 2019 Resolved
1 child pfd was unsatisfactory. Provide 1 child PFD in accordance with 46 CFR 180.71. Vessel limited to 2 persons under 90lbs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 December 2019
Resolution: Child PFDs provided.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 9 December 2019 Resolved
E-pirb battery was expired. Repair/renew in accordance with 46 CFR 176.808. Vessel limted to within 3 miles of shore.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 January 2020
Resolution: New E-pirb provided.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 December 2019 Resolved
DSC VHF Radio was not provided. Provide DSC capable radio in accordance with 46 CFR 184.502.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 15 January 2020
Resolution: DSC radio provided.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 9 December 2019 Resolved
Lights for operation of automatic bilge pumps were missing. Provide in accordance with 46 CFR 182.530.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 15 January 2020
Resolution: Lights provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 December 2019 Resolved
Name was not present on port and stbd bow. Provide markings in accordance with 46 CFR 67.123
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2020
Resolved 30 December 2019
Resolution: Markings provided.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 4 December 2018 Resolved
Fixed Gas Fire Extinguishing System- The vessel’s fixed gas fire extinguishing system was undersized for the space in which it was installed. Replace current fixed gas fire extinguishing system with one of proper size as described on the vessel’s certificate of inspection.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 April 2019
Resolution: Correct extinguishing system installed.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 4 December 2018 Resolved
Fixed Gas Fire Extinguishing System- The vessel was unable to prove proper maintenance and servicing of its fixed gas fire extinguishing system. Per 46 CFR 181.420 prove proper instillation, inspection, and operating of the vessel’s fixed gas fire extinguishing system.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 16 April 2019
Resolution: Video of correct operation and installation of new cylinder provided.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 4 December 2018 Resolved
Bilge High Level Alarm- The vessel’s forward centerline bilge high level alarm was inoperable. Prove proper operation of bilge high level alarm in accordance with 46 CFR 182.530.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 December 2018
Resolution: Alarm repaired.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 4 December 2018 Resolved
Inflatable Buoyant Apparatus (IBA) - The vessel’s IBA did not have current inspection/ service markings or documentation. Prove proper servicing of IBA in accordance with 46 CFR 185.730
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 December 2018
Resolution: Service report provided.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 4 December 2018 Resolved
Watertight Bulkheads- Observed 03 watertight bulkhead penetrations that were not sealed between the engine room and midship watertight compartments. Find and replace plugs / ensure watertight integrity of that bulkhead per 46 CFR 179.320.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 13 December 2018
Resolution: Penetrations plugged.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 February 2018 Resolved
Port running light was extinguished. Repair in accordance with 46 CFR 183.420. Vessel is restricted to daylight operations.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 March 2018
Resolution: Light repaired.
Navigation › Piloting/Steering › Magnetic Compass
Issued 22 February 2018 Resolved
Compass light extinguished. Repair in accordance with 46 CFR 184.402. Vessel is restricted to daylight operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 March 2018
Resolution: Light repaired.

Casualty record · 2

19 July 2019Routine · role: Involved in a Marine Casualty · activity 6755383
9 August 2023Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · activity 7792469
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.