MAURY USCG vessel records Sign in
← All vessels

MV AGIA EKATERINI

MV AGIA EKATERINI is a 2009 freight ship. The Coast Guard has recorded 2 inspections since 2015, most recently in April 2016, along with 5 deficiencies and 1 operational control.

Records from 2015 to 2016. Most recent: inspection, 30 April 2016.

Built
2009
Last inspected
30 April 2016
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9413078 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
1255623
Flag
PANAMA
—
Maury page id
psix-1255623

Inspections, by type

Years with a record 2 calendar years (2015–2016)
The 2 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it11767 - Convention (Subpart B), Gross Ton
6023 - Convention (Subpart B), Net Ton
18930 - Dead Weight, Metric Ton
23612 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 2

30 April 2016 Ballast Water Examination · PII Safety Exam · ISPS III Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5860679
14 November 2015 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5759646

Deficiency record · 5

Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 30 April 2016 Resolved
2540- ISM Emergency Preparedness- Crew not familiar with essential shipboard procedures relating to the safety of ship. PSCO observed the painter line improperly attached to both port and starbard liferafts preventing the proper operation of the automatic inflation devices. 74 SOLAS(am) XI-I/4
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 April 2016
Resolved 10 May 2016
Resolution: Crew Familiarization was carried out on life raft attachment by Class. Report sumbitted to USCG.
Lifesaving › Inflatable Liferafts › Painter
Issued 30 April 2016 Resolved
0628- Stowage of Liferafts- Each liferaft or group of liferafts shall be stowed so that each floats free and, if inflatable, inflates automatically when the ship sinks. PSCO observed the painter line improperly attached to both the vessel's port and starboard liferafts, rendering the liferafts unable to automatically inflate when released. 74 SOLAS(am) III/13.4.2
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 30 April 2016
Resolution: Chief Mate corrected painter arrangements on the spot.
Fire Fighting › Remote Fuel Shutoff › General
Issued 14 November 2015 Resolved
0750-Fire Prevention- Fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs. PSCO observed the quick closing guel shutoff valve on the D.O. Service Tank for the ship's service generators blocked in the open position with a wooden block. SOLAS 74(09) II-2/14 & II-2/4.2.2.3.4
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 14 November 2015
Resolved 15 November 2015
Resolution: Received, reviewed, and accepted class report from [name withheld] stating the deficiency was rectified. Surveyor tested the fuel valve's remote shut off satisfactorily and verified valve was operating in accordance with manufacturer's instructions.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 14 November 2015 Resolved
1740- The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without presenting an unreasonable threat of harm to the marine environment. C/E stated the OCM could not recall information. PSCO then observeed engineering crew unable to recall data after following instructions in manufacturer's manual. MARPOL I/6.4.1
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 December 2015
Resolved 15 November 2015
Resolution: Received, reviewed, and accepted class report from [name withheld] stating the deficiency was rectified. Master and C/E conducted training on OCM maintenance and operation IAW with instruction manual. BV surveyor verified that crew could recall data.
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 14 November 2015 Resolved
0715-Detection-The function of fixed fire detection systems shall be periodically tested to the satisfaction of the Administrations by means of equipment producing smoke associated with incipient fires to which the detector is designed to respond. Crew was unable to test smoke detector located over M/E due to a lack of equipment. SOLAS 74(am) II-2/ 7.3.2
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 December 2015
Resolved 15 November 2015
Resolution: Received, reviewed, and accepted class report from [name withheld] stating the deficiency was rectified. Ship's Crew fabricated on board a long bar with equipment to test fire smoke detectors on M/E and other areas. Detectors tested.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.