Records from 2015 to 2026. Most recent: inspection, 29 April 2026.
Documentation record
Registered dimensions (L × B × D)26.9 ft × 10.0 ft × 4.9 ft
Registered tonnagegross 8 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderFORTIER BOATS INC · SOMERSET, MA, UNITED STATES · built 2013
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portPERTH AMBOY, NJ
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 4 May 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 18
29 April 2026
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8357892
12 May 2025
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8132987
2 December 2024
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8041768
31 May 2024
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7909215
2 June 2023
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7703532
3 March 2023
Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7644905
9 December 2022
Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7595645
13 May 2022
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7595669
21 May 2021
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7205515
7 December 2020
Hull Examination · Internal Structural Exam · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7107365
15 June 2020
COI Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6973854
31 May 2019
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6699088
14 November 2018
Internal Structural Exam · Examination of Repairs · Deficiency Check · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6581512
10 May 2018
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6414746
18 May 2017
Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6148992
21 April 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6129524
17 May 2016
Deficiency Check · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5879283
13 August 2015
Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5214115
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 17 May 2016
Resolved
HATCH COVERS MUST BE ATTACHED BY DEVICES OF SUBSTANTIAL STRENGTH TO PREVENT ITS LOSS
Action required: 705 - Other - as specified
Due 31 May 2016
Resolved 25 May 2016
Resolution: Attached hatch with cable.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 17 May 2016
Resolved
PROVIDE A NEW FIRST AID KIT
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 25 May 2016
Resolution: Provided new first aid kit.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 May 2016
Resolved
POST COI IN LOCATION VISIBLE TO PASSENGERS
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 25 May 2016
Resolution: Posted COI.