Records from 2016 to 2026. Most recent: inspection, 3 March 2026.
Inspection history · 9
3 March 2026
Simplified Stability Test
Physical examination · Marine Safety Center (MSC) · Activity 8328125
12 January 2026
DAPI Audit · COI Inspection · Hull Examination · Special Consideration · Administrative Inspection · Examination of Repairs · Internal Structural Exam · Vessel Attendance · Drydock Exam · Special
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 8285601
31 August 2018
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6528416
22 November 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6045674
4 November 2016
DAPI Audit · Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6035366
31 August 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5988636
9 August 2016
Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5967741
15 July 2016
Administrative Inspection · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5941711
14 July 2016
Type not recorded
No type recorded · Station Gulfport · USCG Heartland District (CGD-H) · Activity 5941521
Electrical › Electrical Distribution System (service) › Panelboard
Issued 14 November 2016
Resolved
12 volt panel board was not all labeled.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 November 2016
Resolved 14 November 2016
Resolution: Labeled during inspection.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 14 November 2016
Resolved
Supervisory training not completed for new master.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 December 2016
Resolved 15 November 2016
Resolution: Provided documentation of completion of resquired supervisory training.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 14 November 2016
Resolved
Port red light for navigation not working.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 16 November 2016
Resolved 14 November 2016
Resolution: Repaired and tested during inspection.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 26 July 2016
Resolved
No copy of DAPI policy or proof of enrollment on board. Provide copy of DAPI policy and proof of enrollment for all crew
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 August 2016
Resolved 8 September 2016
Resolution: DAPI policy and enrollment letter provided.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 26 July 2016
Resolved
No means to conduct alcohol testing on board. Provide approved alcohol testing device for crew. Restricted to trip of no more than 2 hours until cleared by CG Marine Inspector.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 August 2016
Resolved 9 August 2016
Resolution: Purchased Alcohol strips, expire 06-2017.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 26 July 2016
Resolved
EAP hotline and proof of required training not provided. Post EAP hotline and provide proof of completion of required training for crew
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 August 2016
Resolved 8 September 2016
Resolution: EAP information provided.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 26 July 2016
Resolved
Provide current and corrected nautical chart
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 26 September 2016
Resolved 25 October 2016
Resolution: Received photos and receipts from owner.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 26 July 2016
Resolved
Provide current copy of US Coast Pilot and CG Light List.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 August 2016
Resolved 8 September 2016
Resolution: Current copies of required pubs provided.
Documentation › Certificates/Documents › Stability Letter
Issued 26 July 2016
Resolved
Stability letter not on board. Provide copy of stability letter
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 26 August 2016
Resolved 8 September 2016
Resolution: Stability letter provided.