STOLT BELUGA

STOLT BELUGA is a 2013 tank ship. The Coast Guard has recorded 9 inspections since 2017, most recently in January 2026, along with 5 deficiencies.

Records from 2017 to 2026. Most recent: inspection, 29 January 2026.

Built
2013
Last inspected
29 January 2026
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 January 2026
Operational controls None recorded without a removal date
Years with a record 6 calendar years (2017–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9613965
1257230
Flag
LIBERIA
Maury page id
psix-1257230

Documentation record

Tonnage as PSIX records it19899 - Convention (Subpart B), Gross Ton
9762 - Convention (Subpart B), Net Ton
33552 - Dead Weight, Metric Ton
42433 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 9

29 January 2026 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8303592
28 August 2025 PSC B · COC-CHEM & TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8214265
20 August 2024 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7985520
9 August 2024 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7977932
31 July 2024 COC-CHEM & TVE Renew · PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7967623
9 January 2023 Deficiency Check
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7619154
7 November 2022 Ballast Water Examination
Physical examination · Marine Safety Detachment Fort Macon · USCG East District (CGD-E) · Activity 7590348
31 October 2022 COC-CHEM Renew · PSC B
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 7584131
19 July 2017 COC-CHEM & TVE Renew · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6209421

Deficiency record · 5

07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 31 July 2024 Resolved
The inert gas system referred to in chapter II-2 of the convention shall be designed, constructed and tested to the satisfaction of the administration. PSCO observed inop transformer in #2 feed pump compressor. 74 SOLAS (CONS 2020) II-2/5.5.1.1 FSS Code CH 15 2.2.1.1
Action required: 15 - Rectify deficiencies by next port
Due 7 August 2024
Resolved 8 August 2024
Resolution: Class witnessed operation
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Shipboard operations
Issued 31 July 2024 Resolved
In meeting these requirements, the company should ensure that any non-conformity is reported, with its possible cause if known. Vessel did not follow SMS procedures "following an event the master shall call the ship superintendent, or his alternate" for the issue with the #2 feed pump compressor. 74 SOLAS (CONS 2020) IX/ 3.1 ISM Code 10.2.2
Action required: 15 - Rectify deficiencies by next port
Due 7 August 2024
Resolved 8 August 2024
Resolution: Class investigated. Recommended internal audit.
07 - Fire Safety › N/A - No Subsystem › Inert gas system
Issued 31 July 2024 Resolved
A fixed inert gas system in accordance with the requirements of the FSS CODE, automatic shutdown of cargo pumps shall be provided to operate on predetermined limits of pressure in the inert gas main being reached. IG main low low alarm could not be demonstrated. Cannot load cargoes that require inerting. 74 SOLAS (CONS 2020) II-2/5.5.1.1 FSS CODE CH 15 2.2.4.5.3
Action required: 705 - Other - as specified
Due 7 August 2024
Resolved 8 August 2024
Resolution: Class witnessed operation.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 31 July 2024 Resolved
Hoses that transfer vapors must have flanges that have a bolt hole arrangement with requirements for 150 pound class ANSI B16.5 flagnes and one diameter (0.625 inch) stud located midway between bolt holes and in line with the bolt hole pattern. PSCO observed vapor hose without stud. 46 CFR 39.2001 (i) (5)
Action required: 10 - Deficiency Rectified
Due 31 July 2024
Resolved 31 July 2024
Resolution: Crew removed vapor hose line from cargo operation use.
14 - Pollution Prevention › 148 - Ballast Water › Ballast Water Management System (BMWS)
Issued 7 November 2022 Resolved
The master, owner, operator, agent, or person in charge of a vessel equipped with ballast tanks that operates in the waters of the United States must employ one of the following ballast water management methods: Install and operate a ballast water management system (BWMS) that has been approved by the Coast Guard under 46 CFR part 162. The BWMS must be installed in accordance with § 151.2035(b) of this subpart. Following installation, the master, owner, operator, agent, or person in charge of the vessel subject to this subpart must properly maintain the BWMS in accordance with all manufacturer specifications. Unless otherwise expressly provided for in this subpart, the master, owner, operator, agent, or person in charge of vessels employing a Coast Guard-approved BWMS must meet the applicable ballast water discharge standard (BWDS), found in § 151.2030 of this subpart, at all times of discharge into the waters of the United States. The vessel reported an inoperable ballast water management system to USCG Sector North Carolina and would not be able to rectify the deficiency while operating in the waters of the United States. The vessel must complete a ballast water exchange in an area 200 nautical miles from any shore between ballast water discharge events into the waters of the United States. 33 CFR 151.2025(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 9 January 2023
Resolution: Received technician report attesting to repairs for BWMS and proper operation.