Records from 2003 to 2017. Most recent: inspection, 14 November 2017.
Documentation record
Registered dimensions (L × B × D)40.1 ft × 12.0 ft × 4.9 ft
Registered tonnagegross 17 / net 11
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderLAFCO, INC. · LAFAYETTE, LA, UNITED STATES · built 1973
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCORPUS CHRISTI, TX
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Regulatory (Subpart C or D), Net Ton
17 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 12 October 2017
Resolved
Crew must be enrolled in random drug testing program. Provide proof of enrollment to CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 January 2018
Resolution: Brown Water Marine provided an updated policy, verified proper drug testing results for relevant testing, and implemented proper random testing procedures.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 12 October 2017
Resolved
Vessel's FCC Safety Certificate is expired. Provide valid FCC Safety Certificate to CG Marine Inspector. 47 CFR 80.401
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 October 2017
Resolution: Provided valid FCC Safety Certificate
Engineering › Bilge Water Management System › Pump
Issued 12 October 2017
Resolved
A hand portable bilge pump is not provided onboard. Vessel must have a portable hand pump onboard.
Action required: 705 - Other - as specified
Due 19 October 2017
Resolved 16 October 2017
Resolution: Provided new portable hand pump for the vessel
Accommodation/Occupational Safety › Ventilation › General
Issued 12 October 2017
Resolved
Holes in bulkhead between engine compartment and passenger space allows for communication of vapors between the space. Prevent communication of vapors to the satisfaction of the attending CG Marine Inspector. 46 CFR 176.25-50(a)
Action required: 705 - Other - as specified
Due 19 October 2017
Resolved 16 October 2017
Resolution: Plugged holes to the satisfaction of the attending Marine Inspector
Engineering › Bilge Water Management System › Interface Detector
Issued 12 October 2017
Resolved
Bilge alarm for forward peak does not sound. Bilge alarms must be audible and visual. Provide audible alarm to the satisfaction of the attending CG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 October 2017
Resolution: Provided satisfactory audible alarm
Engineering › Fuel Oil Service System › Valve
Issued 12 October 2017
Resolved
Fuel shutoff valves must be labelled in one inch lettering. Correctly label purpose and direction of operation of fuel shutoff valve.
Action required: 705 - Other - as specified
Due 19 October 2017
Resolved 16 October 2017
Resolution: Properly labelled fuel shutoff valves
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 12 October 2017
Resolved
All charts and publications must be up-to-date. Provide up-to-date charts. 46 CFR 185.20-35
Action required: 705 - Other - as specified
Due 19 October 2017
Resolved 19 October 2017
Resolution: Provided new charts
Fire Fighting › Fire Bucket › Quantity
Issued 12 October 2017
Resolved
Fire buckets were not provided on board. Three 2.5 gallon fire buckets are required onboard.
Action required: 705 - Other - as specified
Due 12 October 2017
Resolved 12 October 2017
Resolution: Corrected on the spot.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 October 2017
Resolved
Life buoy waterlight battery was expired. Life buoy lights shall be replaced during annual inspections, if the expiration date has passed.
Action required: 705 - Other - as specified
Due 12 October 2017
Resolved 12 October 2017
Resolution: Corrected on the spot.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 4 October 2017
Resolved
Vessel did not have the Annual Inspection for 2017. Vessel has lapsed in periodicity. Annual Inspection. Your vessel must undergo an annual inspection within 3 months before or after each anniversary date.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 12 October 2017
Resolution: Completed Annual Inspection
Engineering › Steering Gear System › Ram Seal
Issued 8 November 2016
Resolved
Port Steering Ram seal excessive leak.
Action required: 705 - Other - as specified
Due 18 December 2016
Resolved 1 December 2016
Engineering › Steering Gear System › Rudder Stock
Issued 8 November 2016
Resolved
Rudder Stock packing gland rotating freely. Should be stationary. Indicative of excessive packing. Bracket wasted, requires reinforcement.
Condition: Improper/Lack of Maintenance
Due 8 December 2016
Resolved 1 December 2016
Resolution: Repacked packing gland and reinforced bracket with weld.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 12 May 2016
Resolved
Vsl has aluminum rescue ladder/platform for MOB retrieval. No safety harness with tether line present on vsl for use by deck hand.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 12 May 2016
Resolution: Harness & Tether Line located and placed for use on vsl. Corrected on the spot.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 12 May 2016
Resolved
First Aid Kit onboard contained expired items.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 12 May 2016
Resolution: First Aid kit onboard replaced. Corrected on the spot.
Documentation › Certificates/Documents › FCC SSL
Issued 12 May 2016
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 13 May 2016
Resolution: Forwarded proof of current Station License, placed onboard vsl.
Deck/Cargo › Holds/Tanks › Flame Arrester
Issued 12 May 2016
Resolved
Flame Screen missing. Replaced.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 May 2016
Resolved 12 May 2016
Resolution: Corrected on the spot.