MAURY USCG vessel records
← All vessels

PROTECTOR ST. GEORGE

PROTECTOR ST. GEORGE is a 2011 freight ship. The Coast Guard has recorded 13 inspections since 2017, most recently in September 2022, along with 25 deficiencies and 4 operational controls.

Records from 2017 to 2022. Most recent: inspection, 27 September 2022.

Built
2011
Last inspected
27 September 2022
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 September 2022
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 4 calendar years (2017–2022)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9602992
1257388
Flag
LIBERIA
Maury page id
psix-1257388

Documentation record

Tonnage as PSIX records it32962 - Convention (Subpart B), Gross Ton
19142 - Convention (Subpart B), Net Ton
67681 - Displacement, Metric Ton
56632 - Dead Weight, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 13

27 September 2022 Appeal
Administrative · Commandant (CG-CVC) · Activity 7598960
26 September 2022 Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7566308
15 September 2022 PSC B
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7556863
7 September 2022 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7546140
11 August 2022 Deficiency Check · PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7528268
8 January 2021 PSC B
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7117185
1 October 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6546496
29 September 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6551205
25 September 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6548539
22 August 2017 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6248654
31 July 2017 PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6225996
30 July 2017 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6225545
13 March 2017 PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6104125

Deficiency record · 25

06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 15 September 2022 Resolved
06103- OTHER (CARGO)- THE CARRIAGE OF SOLID BULK CARGOES OTHER THAN GRAIN SHALL BE IN COMPLIANCE WITH THE RELEVANT PROVISIONS OF THE IMSBC CODE. BILGE LINES, SOUNDING PIPES AND OTHER SERVICE LINES WITHIN THE CARGO SPACE SHALL BE IN GOOD ORDER. PSCO OBSERVED FRESHWATER SERVICE LINES TO PORT SIDE CARGO HOLDS 4 AND 5 ARE CORRODED AND DETERIORATED TO AN EXTENT THAT SERVICE LINES ARE NOT IN GOOD WORKING ORDER. 74 SOLAS 20 VI/1-2, IMSBC CODE 2.2.3
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 23 September 2022
Resolution: Vessel submitted report for Flag attesting to the deficiency being rectified.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 7 September 2022 Resolved
After any survey of a ship under article 14 has been completed, no change shall be made in the arrangements covered by the survey. PSCO observed opening in watertight bulkhead being continuously left open, with ship equipment being stowed in the confined space the opening leads to in the forecastele, with the space being labeled on the opening as forepeak tank. Provide clarification on storage use for the space. ICLL Reg 15 40AC
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 8 September 2022
Resolution: Received, reviewed and accepted class report from LR directing the proper use of the void space.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 September 2022 Resolved
Cables and wiring shall be installed and supported in such a manner as to avoid chafing and other damage. PSCO observed protective electrical cable conduit piping on deck with fractures in various joints along the port side. 74 SOLAS (2014) II-1/45.5.5 40AC
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 7 September 2022
Resolved 26 September 2022
Resolution: Received, reviewed and accepted Class report from LR attesting to permanent repairs being conducted to the eectrical conduit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 7 September 2022 Resolved
The machinery and associated piping systems shall be adequate for service. PSCO witnessed jacket water leak on main engine cylinder number five. 74 SOLAS (2014) II-1/26.1 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 September 2022
Resolved 12 September 2022
Resolution: Received, reviewed and accepted class report from LR attesting to the operational readiness of jacket water cooling system on the MDE.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 7 September 2022 Resolved
Every ship of 400GT and above shall carry a garbage management plan which the crew shall follow. PSCO observed large drums with black plastic trash bags full of oily rags in various spaces throughout the engine room, not stored in accordance with the vessel's garbage management plan. Request clarification from administration. MARPOL 17AC
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 8 September 2022
Resolved 8 September 2022
Resolution: Received, reviewed and accepted class report from LR attesting to the removal of the excss oily rags and cleaning material from the vessel.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 11 August 2022 Resolved
15109 - The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. Due to the objective evidence detailed in the below deficiencies, the vessel is not in substantial compliance with relevant conventions, calling into question the adequacy and implementation of the vessel’s SMS under the ISM code. An external audit conducted by the Flag or RO is required to determine whether the ship is operating in accordance with the ISM Code. Provide a copy of the completed audit report to USCG prior to departure from port. 74 SOLAS(20)IX/3.1 ISM A/10.1 30BC
Action required: 30 - Ship detained
Resolved 28 August 2022
Resolution: Vessel had an external audit completed by Flag (Liberia). See attached documentation.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 August 2022 Resolved
07126 - The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: means shall be provided to control leaks of flammable liquids. PSCO observed active fuel oil leaks from the SSDGs, fuel oil purifiers, and an extensive amount of oil in the bilge. 74 SOLAS(09)II-2 / 4.1.1 30AC
Action required: 30 - Ship detained
Resolved 28 August 2022
Resolution: Vessel's engineering department rectified above deficiency.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 11 August 2022 Resolved
07126 - The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met. The ignitability of combustible materials shall be restricted. PSCO observed oil soaked lagging throughout the engine room. 74 SOLAS(09)II-2 / 4.1.3 30AC
Action required: 30 - Ship detained
Resolved 28 August 2022
Resolution: Vessel's engineering department extensively cleaned engine room bilge.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 August 2022 Resolved
07106 - Maintenance, testing and inspections shall be carried out based on the guidelines developed by the organization and in a manner having due regard to ensuring the reliability of fire-fighting systems and appliances. PSCO discovered the crew does not have the approved testing equipment to test heat and flame detectors. Additionally, crew was unable to provide PSCO with appropriate logbook entries. 74 SOLAS(09)II-2 / 14.2.2.1 30AC
Action required: 30 - Ship detained
Resolved 28 August 2022
Resolution: Vessel obtained proper testing equipment for testing the various fire detection systems.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 August 2022 Resolved
07106 - The purpose of this regulation is to maintain and monitor the effectiveness of the fire safety measures the ship is provided with. For this purpose, the following functional requirements shall be met: 2 fire protection systems and firefighting systems and appliances shall be maintained ready for use. PSCO observed multiple system “fault” error codes on the vessel’s smoke sampling detection system, including a low flow code and a smoke detector code. Vessel’s electrician was unable to rectify the system error codes. 74 SOLAS(09)II-2 / 14.1.1 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2022
Resolution: Smoke sampling system has been restored fully operational.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 11 August 2022 Resolved
07106 - Machinery spaces of Category A containing oil-fired boilers or oil fuel units shall be provided with any one of the fixed fire-extinguishing systems in paragraph 4.1 PSCO observed a flame detector covered in heavy oil in the fuel purifier room, rendering it inoperable. 74 SOLAS(09)II-2 / 10.5.1.1 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2022
Resolution: Flame detector has been cleaned and tested, found to be operational.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 11 August 2022 Resolved
08107 - The condition of this ship and its equipment shall be maintained to conform with the regulations to ensure that the ship in all respect, will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed SSDG numbers 1,2, and 3, were continuously alarming for high exhaust temperature. 74 SOLAS(20)I / 11 a 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2022
Resolution: SSDG's have been overhauled and are fully operational. Tests were conducted in the presence of Flag and Class.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 11 August 2022 Resolved
11104 - Rescue boat embarkation and launching arrangements shall be such, that the rescue boat can be boarded and launched in the shortest possible time. PSCO observed seized straps rendering the rescue boat incapable of being launched. 74 SOLAS(20)III / 17.1 30AC
Action required: 30 - Ship detained
Resolved 28 August 2022
Resolution: Rescue boat securing straps have been renewed and rescue boat is fully operational.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 11 August 2022 Resolved
08110 - The central operating console at the navigation bridge shall be provided with a diagram showing the location of each door, with visual indicators to show whether each door is open or closed. PSCO observed the watertight door panel on the bridge to be inoperable when tested. 74 SOLAS(20)II-1 / 13.8.2 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2022
Resolution: Vessel's watertight door panel has been restored to fully operational condition. Tested various doors and found system to be satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 11 August 2022 Resolved
11118 - Lifesaving appliances shall comply with the provisions of SOLAS and the code. PSCO observed inadequate and deteriorated reflective tape on lifejackets located in the BOSN store and bridge. 74 SOLAS(20)III / 4.2.1 LSA 1.2.1 17AC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2022
Resolution: Lifejacket retro-reflective tape has been renewed. Lifejackets are in satisfactory condition.
01 - Certificates & Documentation › 012 - Crew Certificates › Manning specified by the minimum safe manning doc
Issued 11 August 2022 Resolved
01209 - Subject to the provisions of regulation 1/10, paragraph 5, any certificate required by the convention must be kept available in its original form on board the ship on which the holder is serving. PSCO observed all members of the crew, except for three crew-members did not have original endorsements onboard. STCW I / 2.11 17BC
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 August 2022
Resolution: Vessel's Officers' have onboard all appropriate flag state license endorsements.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 August 2022 Resolved
99101 - The frequency of the tests and inspections required by this section must be: for vessels, annually or as part of biennial and mid-period inspections. PSCO observed both port and starboard fuel oil bunker lines were not annually tested. 33CFR156.170 (f)(3) 40C
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 15 September 2022
Resolution: PSCO observed satisfactory pressure test conducted on 09SEP22 during PSC exam on 15SEP22. See attached pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 11 August 2022 Resolved
09209 - All electrical apparatus shall be so constructed and so installed as to not cause injury when handled or touched in a normal manner. PSCO observed wasted electrical receptacle leading to the port side bridge wing whistle. Frayed and exposed wires were identified on the lifeboat embarkation lighting switch, and multiple plugs and switches throughout the house. 74 SOLAS(20)II-1 / 45.1.3 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 August 2022
Resolution: Open receptacles throughout the vessel have been renewed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 11 August 2022 Resolved
13104 - An efficient bilge pumping system shall be provided, capable of pumping from and draining any watertight compartment other than a space permanently appropriated for the carriage of fresh water, water ballast, oil fuel, or liquid cargo and for which other efficient means of pumping are provided, under all practical conditions. PSCO observed deteriorated/wasted strainers on the dewatering piping in FWD Bosun locker, and lower forepeak storage space. 74 SOLAS(20)II-1 / 35-1.2.1 40AC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 28 August 2022
Resolution: Vessel renewed, and or removed wasted bilge suction strainers.
09 - Working and Living Conditions › 092 - Working Conditions › Gangway, accommodation-ladder
Issued 11 August 2022 Resolved
09223 - For all ships the means of embarkation and disembarkation shall be inspected and maintained in suitable condition for their intended purpose. PSCO observed STBD side embarkation gangway’s limit switch was broken and would not function as designed. 74 SOLAS(20)II-1 / 3-9.3 50AC
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 28 August 2022
Resolution: Starboard side gangway's limit switch was replaced and is operational.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 11 August 2022 Resolved
11108 - Every life raft shall be stowed with its painter permanently attached to the ship. PSCO observed port side life raft painter was not properly attached to the hydrostatic release units weak link. 74 SOLAS(20)III / 13.4.1 10C
Action required: 10 - Deficiency Rectified
Resolved 11 August 2022
Resolution: Crew attached life raft painter to frame.
02 - Structural Conditions › N/A - No Subsystem › Loading/Ballast condition
Issued 11 August 2022 Resolved
02134 - The arrangement of the bilge and ballast pumping system shall be such as to prevent the possibility of water passing from the sea and from water ballast spaces into the cargo and machinery spaces, or from one compartment to another. PSCO was notified by crew that ballast water piping is not working as intended. Crew states when performing ballast operations unintended ballast tanks are being filled or emptied not in alignment with vessel's ballast arrangements. Additionally, cargo hold #2 bilge tank has water ingress while filling DBT #2 and WBT #2 starboard side. 74 SOLAS (20) II-1 / 35-1 2.4 60ABC
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 26 September 2022
Resolution: PSC NOLA received a class report from Lloyd's Register satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 1 October 2018 Resolved
13102 Propulsion and Auxiliary Machinery The machinery, boilers and other pressure vessels associated piping systems and fittings shall be of a design and contruction adequate for the service for which they are intended and shall be so installed and protected as to reduce the minimum and danger to persons on board, due regard being paid to moving parts hot surfaces and other hazards. PSCO observed crank case breather piping disconnected and temporary rubber hose connected and venting to a bucket one deck above in the space. SOLAS 74 (a) 2014 CONS II-1/26.1 16a
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 October 2018
Resolved 6 October 2018
Resolution: PSC NOLA recieved a class report from CSS satisfying the requirement.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 October 2018 Resolved
99101 Other (Safety in general) Cylinders must always be secured and when not in use they must be stowed in a rack in an upright position with the valve protection cap in place. PSCO observed oxygen and acetylene bottles in the locker are improperly secured, missing protection caps, and resting directly on the deck. 46 CFR 147.60(b) 40c
Condition: Improper/Lack of Maintenance
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 October 2018
Resolution: PSC NOLA recieved a class report from CSS satisfying the requirement.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Safety and environment policy
Issued 1 October 2018 Resolved
15101 Safety and environment policy Maintain a ballast water management (BWM) plan that has been developed specifically for the vessel and that will allow those responsible for the plan's implementation to understand and follow the vessel's BWM strategy and comply with the requirements of this subpart. PSCO observed vessel conducting E/R for FPT, BWM plan states FPT will be conducted with flow through exchange. 33 CFR 151.2025(g) 40a
Condition: Placed in Improper Service
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 6 October 2018
Resolution: PSC NOLA recieved a class report from CSS satisfying the requirement.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.