MAURY USCG vessel records Sign in
← All vessels

PACIFIC QUEST

PACIFIC QUEST is a 1973 passenger vessel (inspected). The Coast Guard has recorded 27 inspections since 2002, most recently in August 2018, along with 32 deficiencies, 3 operational controls and 3 casualty investigations between 2016 and 2018.

Records from 2002 to 2018. Most recent: inspection, 12 August 2018.

Built
1973
Last inspected
12 August 2018
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC6431
125740
Flag
UNITED STATES
367056322 (licence lapsed)
Maury page id
psix-125740

Inspections, by type

…with no type recorded8
Years with a record 9 calendar years (2002–2018)
The 27 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it39 - Simplified, Net Ton
49 - Simplified, Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDC6431MMSI 367056322 · cancelled · compulsorily equipped · granted 6 June 2015, cancelled 23 August 2018
WCE8036MMSI not assigned · expired · voluntarily equipped · granted 28 March 1994, cancelled 30 May 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

THE BOARD ROOM Passenger (Uninspected) · MISLE 301518 · 25 June 2016 · activity 5924646USCGC HALIBUT (WPB 87340) Public Vessel, Unclassified · MISLE 1322730 · 25 June 2016 · activity 5924646

Inspection history · 27

12 August 2018 Administrative Inspection · In-Service Inspection · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6510869
12 August 2018 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6511132
2 March 2018 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6353835
9 February 2018 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6350021
5 January 2018 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6333441
2 November 2017 Type not recorded
No type recorded · USCGC BLACKTIP (WPB 87326) · USCG Arctic District (CGD-A) · Activity 6299667
27 January 2017 Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6075741
7 December 2016 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6054945
7 December 2016 Type not recorded
No type recorded · USCGC BLACKFIN (WPB 87317) · USCG Southwest District (CGD-SW) · Activity 6055385
25 June 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5924646
5 May 2016 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5868463
22 April 2016 Drydock Extension
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5860787
17 April 2016 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5857627
16 April 2016 Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5855785
11 April 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5846877
14 June 2012 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4336997
28 February 2012 In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4273793
17 September 2010 In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3850738
5 March 2010 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3690471
5 November 2008 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3357898
11 March 2008 Initial Certification · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3164136
7 December 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2547570
4 November 2005 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2530802
12 February 2005 Plan Review "T" Boat
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2291208
24 May 2004 Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2076867
25 July 2002 Uninspected Passenger Vessel
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1652172
21 February 2002 Type not recorded
No type recorded · USCG Southwest District (dr) · USCG Southwest District (CGD-SW) · Activity 1488159

Deficiency record · 32

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 August 2018 Resolved
Whenever damage or deterioration to hull plating or structural members that affect seawhorthiness of a vessel is discovered, OCMI may conduct an ISE. Vessel ran hard aground and must complete a hull inspection by Sector SF Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 August 2018
Resolved 13 August 2018
Resolution: Vessel destroyed. COI deactivated.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 March 2018 Resolved
Provide proof of servicing for vessels fixed and portable firefighting prior to expiration of current servicing report that is valid through 28MAR2018.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2018
Resolved 16 March 2018
Resolution: Vessel O/O provided proof of fixed and portable firefighting service by Global Fire and Safety, Inc. on 15MAR2018.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 27 January 2017 Resolved
Provide service report for fire fighting equipment prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 January 2017
Resolved 2 March 2018
Resolution: Vessel provided servicing certificate date 28MAR2017. Inspector issued new requirement to conduct fire servicing prior to experation of current certificate.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 27 January 2017 Resolved
Provide proper testing equipment per manufacturer to prove proper operation of Ansul fire detection system prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 January 2017
Resolved 2 March 2018
Resolution: O/O was able to proof testing capability of Ansul fire detection system.
Operations/Management › Drills/Instruction › Not Conducted
Issued 27 January 2017 Resolved
Get vessel underway with crew per COI and demonstrate proper emergency drills prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 January 2017
Resolved 2 March 2018
Resolution: Vessel conducted satisfactory sea trial and emergency drills.
Electrical › Electric Generation Source (service) › Generator
Issued 27 January 2017 Resolved
Prove proper operation of the genset.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: O/O was able to proof proper operation of the generator under load.
Engineering › Bilge Water Management System › Pump
Issued 27 January 2017 Resolved
Prove proper operation of the bilge portable hand pump to reach deepest void space.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: O/O was able to proof proper operation of the portable hand pump while reaching the deepest void space.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 27 January 2017 Resolved
Pump out water in fwd peak.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: Forward peak compartment was clear of any water.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 27 January 2017 Resolved
Service fwd and aft hatches.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: O/O was able to prove proper operation of forward and aft hatches.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 27 January 2017 Resolved
Provide current DAPI program paperwork to include MIS report, employee list, and Consortium compliance letter.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: O/O provided all documentation for DAPI program.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 January 2017 Resolved
Replace stbd nav light, restricted to daylight only.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: O/O demenstrated proper operation of stbd nav light.
Navigation › Piloting/Steering › Marine Charts
Issued 27 January 2017 Resolved
Provide current charts and pubs.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: O/O provided current charts and pubs for all operational areas.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 27 January 2017 Resolved
Provide lights for 07 adult lifejackets; restricted to limited coastwise route or 18 persons.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: MI witnessed proper operation of all lights on 25 adult lifejackets.
Lifesaving › Inflatable Liferafts › Servicing
Issued 27 January 2017 Resolved
Provide service report for liferaft in Feb 2017.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: O/O provided current servicing report.
Communications › Radio Communications › EPIRB
Issued 27 January 2017 Resolved
Replace hydrostatic release for the EPIRB by Apr 2017.
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 2 March 2018
Resolution: O/O installed new EPIRB hydrostatic release.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 27 January 2017 Resolved
Replace aft bridge window.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: O/O replaced aft bridge window.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 January 2017 Resolved
Remove dead end wires in laz and properly mount bilge alarm horizontal.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: Dead end wires removed and bilge alarm was properly mounted.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 December 2016 Resolved
Prove proper operation of the bilge high level alarms prior to sailing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2016
Resolved 8 December 2016
Resolution: Bilge alarms tested sat.
Communications › Radio Communications › VHF Radiotelephone
Issued 7 December 2016 Resolved
Install Class D VHF-DSC radio.
Action required: 705 - Other - as specified
Due 8 January 2017
Resolved 27 January 2017
Resolution: VHF-DSC radio installed and tested sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Distributor (fuel injection)
Issued 16 April 2016 Resolved
Prove proper operation of propulsion equipment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 April 2016
Resolution: Conducted satisfactory inspection and underway checkride of propulsion equipment.
Accommodation/Occupational Safety › Ventilation › General
Issued 24 June 2008 Resolved
Install ventilation for work room per approved proposal (outstanding requirement) to the satisfaction of the attending [name withheld] contains batteries and MSD system.
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 29 July 2008
Resolution: Ventilation is installed
Accommodation/Occupational Safety › Ventilation › General
Issued 24 June 2008 Resolved
Provide/submit proposal for ventilation of the work room space, that also contains 12vdc batteries and MSD, that meets 46 CFR 177.600 and 46CFR183.354(b).
Due 7 July 2008
Resolved 29 July 2008
Resolution: Proposal was submitted
Fire Fighting › Structural Fire Protection - General › Fiber Reinforced Plastic
Issued 14 March 2008 Resolved
Carpet in pax berthing must be made of 100% wool or equivalent.
Due 1 May 2008
Resolved 7 May 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 14 March 2008 Resolved
Once 6kw generator is repaired, prove shut down when CO2 system is activated (pressure switch).
Due 14 May 2008
Resolved 12 June 2009
Resolution: Generator run, and CO2 pressure switch activated. Generator shut down and was able to be started again from local control after reset/override button was pressed.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Nozzle, Injection (fuel injection)
Issued 14 March 2008 Resolved
Repair and prove proper operation of the 6 kw generator.
Due 14 May 2008
Resolved 12 June 2009
Resolution: Generator successfully, run.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 14 March 2008 Resolved
Repair and prove operation of 24 vdc main engine driven alternator.
Due 14 May 2008
Resolved 7 May 2008
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 14 March 2008 Resolved
Replace section of PVC elbow on 21kw generator exhaust system with acceptable material per 182.430 or ABYC P-1.
Due 14 May 2008
Resolved 29 May 2008
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 14 March 2008 Resolved
Provide alcohol test kits.
Due 14 May 2008
Resolved 7 May 2008
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 14 March 2008 Resolved
Install flash bowls on genset fuel filters.
Due 1 April 2008
Resolved 1 April 2008
Stability › Weathertight Integrity › General
Issued 14 March 2008 Resolved
Repair dog on mess deck aft door.
Due 14 May 2008
Resolved 7 May 2008
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 March 2008 Resolved
Install drip shields on all electrical boxes located on fwd bhd of aft mach space.
Due 1 April 2008
Resolved 1 April 2008
Lifesaving › Inflatable Liferafts › Servicing
Issued 14 March 2008 Resolved
Submit/provide servicing cert for 16pp liferaft. Service due 03/08.
Due 1 April 2008
Resolved 1 April 2008

Casualty record · 3

17 April 2016Routine · role: Involved in a Marine Casualty · activity 5857627
25 June 2016Significant Marine Casualty · role: Transiting Vicinity of Primary Subject · serious marine incident, as classified · 3 dead · 3 injured · activity 5924646
12 August 2018Routine · role: Involved in a Marine Casualty · activity 6511132
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.