Records from 2002 to 2018. Most recent: inspection, 12 August 2018.
Inspection history · 27
12 August 2018
Administrative Inspection · In-Service Inspection · Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6510869
12 August 2018
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6511132
2 March 2018
Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6353835
9 February 2018
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6350021
5 January 2018
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6333441
2 November 2017
Type not recorded
No type recorded · USCGC BLACKTIP (WPB 87326) · USCG Arctic District (CGD-A) · Activity 6299667
27 January 2017
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6075741
7 December 2016
Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6054945
7 December 2016
Type not recorded
No type recorded · USCGC BLACKFIN (WPB 87317) · USCG Southwest District (CGD-SW) · Activity 6055385
25 June 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5924646
5 May 2016
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5868463
22 April 2016
Drydock Extension
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5860787
17 April 2016
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5857627
16 April 2016
Administrative Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5855785
11 April 2016
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5846877
14 June 2012
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4336997
28 February 2012
In-Service Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4273793
17 September 2010
In-Service Inspection · Administrative Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3850738
5 March 2010
Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3690471
5 November 2008
Drydock Exam · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3357898
11 March 2008
Initial Certification · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3164136
7 December 2005
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2547570
4 November 2005
Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2530802
12 February 2005
Plan Review "T" Boat
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2291208
24 May 2004
Administrative Inspection
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2076867
25 July 2002
Uninspected Passenger Vessel
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1652172
21 February 2002
Type not recorded
No type recorded · USCG Southwest District (dr) · USCG Southwest District (CGD-SW) · Activity 1488159
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 12 August 2018
Resolved
Whenever damage or deterioration to hull plating or structural members that affect seawhorthiness of a vessel is discovered, OCMI may conduct an ISE. Vessel ran hard aground and must complete a hull inspection by Sector SF Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 August 2018
Resolved 13 August 2018
Resolution: Vessel destroyed. COI deactivated.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 2 March 2018
Resolved
Provide proof of servicing for vessels fixed and portable firefighting prior to expiration of current servicing report that is valid through 28MAR2018.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2018
Resolved 16 March 2018
Resolution: Vessel O/O provided proof of fixed and portable firefighting service by Global Fire and Safety, Inc. on 15MAR2018.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 27 January 2017
Resolved
Provide service report for fire fighting equipment prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 January 2017
Resolved 2 March 2018
Resolution: Vessel provided servicing certificate date 28MAR2017. Inspector issued new requirement to conduct fire servicing prior to experation of current certificate.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 27 January 2017
Resolved
Provide proper testing equipment per manufacturer to prove proper operation of Ansul fire detection system prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 January 2017
Resolved 2 March 2018
Resolution: O/O was able to proof testing capability of Ansul fire detection system.
Operations/Management › Drills/Instruction › Not Conducted
Issued 27 January 2017
Resolved
Get vessel underway with crew per COI and demonstrate proper emergency drills prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 27 January 2017
Resolved 2 March 2018
Resolution: Vessel conducted satisfactory sea trial and emergency drills.
Electrical › Electric Generation Source (service) › Generator
Issued 27 January 2017
Resolved
Prove proper operation of the genset.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: O/O was able to proof proper operation of the generator under load.
Engineering › Bilge Water Management System › Pump
Issued 27 January 2017
Resolved
Prove proper operation of the bilge portable hand pump to reach deepest void space.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: O/O was able to proof proper operation of the portable hand pump while reaching the deepest void space.
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 27 January 2017
Resolved
Pump out water in fwd peak.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: Forward peak compartment was clear of any water.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 27 January 2017
Resolved
Service fwd and aft hatches.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: O/O was able to prove proper operation of forward and aft hatches.
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 27 January 2017
Resolved
Provide current DAPI program paperwork to include MIS report, employee list, and Consortium compliance letter.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: O/O provided all documentation for DAPI program.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 January 2017
Resolved
Replace stbd nav light, restricted to daylight only.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: O/O demenstrated proper operation of stbd nav light.
Navigation › Piloting/Steering › Marine Charts
Issued 27 January 2017
Resolved
Provide current charts and pubs.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: O/O provided current charts and pubs for all operational areas.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 27 January 2017
Resolved
Provide lights for 07 adult lifejackets; restricted to limited coastwise route or 18 persons.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: MI witnessed proper operation of all lights on 25 adult lifejackets.
Lifesaving › Inflatable Liferafts › Servicing
Issued 27 January 2017
Resolved
Provide service report for liferaft in Feb 2017.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: O/O provided current servicing report.
Communications › Radio Communications › EPIRB
Issued 27 January 2017
Resolved
Replace hydrostatic release for the EPIRB by Apr 2017.
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 2 March 2018
Resolution: O/O installed new EPIRB hydrostatic release.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 27 January 2017
Resolved
Replace aft bridge window.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: O/O replaced aft bridge window.
Electrical › Electrical Distribution System (service) › Wiring
Issued 27 January 2017
Resolved
Remove dead end wires in laz and properly mount bilge alarm horizontal.
Action required: 705 - Other - as specified
Due 27 February 2017
Resolved 2 March 2018
Resolution: Dead end wires removed and bilge alarm was properly mounted.
Communications › Alarms/Indicators › Bilge Alarm
Issued 7 December 2016
Resolved
Prove proper operation of the bilge high level alarms prior to sailing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 7 December 2016
Resolved 8 December 2016
Resolution: Bilge alarms tested sat.
Communications › Radio Communications › VHF Radiotelephone
Issued 7 December 2016
Resolved
Install Class D VHF-DSC radio.
Action required: 705 - Other - as specified
Due 8 January 2017
Resolved 27 January 2017
Resolution: VHF-DSC radio installed and tested sat.
Engineering › Diesel Engine (propulsion-reduction gear) › Distributor (fuel injection)
Issued 16 April 2016
Resolved
Prove proper operation of propulsion equipment.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 April 2016
Resolution: Conducted satisfactory inspection and underway checkride of propulsion equipment.
Accommodation/Occupational Safety › Ventilation › General
Issued 24 June 2008
Resolved
Install ventilation for work room per approved proposal (outstanding requirement) to the satisfaction of the attending [name withheld] contains batteries and MSD system.
Action required: 705 - Other - as specified
Due 30 July 2008
Resolved 29 July 2008
Resolution: Ventilation is installed
Accommodation/Occupational Safety › Ventilation › General
Issued 24 June 2008
Resolved
Provide/submit proposal for ventilation of the work room space, that also contains 12vdc batteries and MSD, that meets 46 CFR 177.600 and 46CFR183.354(b).
Due 7 July 2008
Resolved 29 July 2008
Resolution: Proposal was submitted
Fire Fighting › Structural Fire Protection - General › Fiber Reinforced Plastic
Issued 14 March 2008
Resolved
Carpet in pax berthing must be made of 100% wool or equivalent.
Due 1 May 2008
Resolved 7 May 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 14 March 2008
Resolved
Once 6kw generator is repaired, prove shut down when CO2 system is activated (pressure switch).
Due 14 May 2008
Resolved 12 June 2009
Resolution: Generator run, and CO2 pressure switch activated. Generator shut down and was able to be started again from local control after reset/override button was pressed.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Nozzle, Injection (fuel injection)
Issued 14 March 2008
Resolved
Repair and prove proper operation of the 6 kw generator.
Due 14 May 2008
Resolved 12 June 2009
Resolution: Generator successfully, run.
Electrical › Electric Generation Source (service) › Power Requirement
Issued 14 March 2008
Resolved
Repair and prove operation of 24 vdc main engine driven alternator.
Due 14 May 2008
Resolved 7 May 2008
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 14 March 2008
Resolved
Replace section of PVC elbow on 21kw generator exhaust system with acceptable material per 182.430 or ABYC P-1.
Due 14 May 2008
Resolved 29 May 2008
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 14 March 2008
Resolved
Provide alcohol test kits.
Due 14 May 2008
Resolved 7 May 2008
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 14 March 2008
Resolved
Install flash bowls on genset fuel filters.
Due 1 April 2008
Resolved 1 April 2008
Stability › Weathertight Integrity › General
Issued 14 March 2008
Resolved
Repair dog on mess deck aft door.
Due 14 May 2008
Resolved 7 May 2008
Electrical › Electrical Distribution System (service) › Junction Box
Issued 14 March 2008
Resolved
Install drip shields on all electrical boxes located on fwd bhd of aft mach space.
Due 1 April 2008
Resolved 1 April 2008
Lifesaving › Inflatable Liferafts › Servicing
Issued 14 March 2008
Resolved
Submit/provide servicing cert for 16pp liferaft. Service due 03/08.
Due 1 April 2008
Resolved 1 April 2008