Records from 2015 to 2026. Most recent: inspection, 30 March 2026.
Documentation record
Registered dimensions (L × B × D)78.7 ft × 27.0 ft × 10.5 ft
Registered tonnagegross 92 / net 45
ITC dimensions (L × B × D)78.7 ft × 27.0 ft × 10.5 ft
ITC tonnagegross 143 / net 42
BuilderGEO SHIPYARD INC · NEW IBERIA, LA, UNITED STATES · built 2014
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portGULFPORT, MS
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 18 November 2025 · expires 30 November 2026
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it143 - Convention (Subpart B), Gross Ton
92 - Regulatory (Subpart C or D), Gross Ton
42 - Convention (Subpart B), Net Ton
45 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 24
30 March 2026
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8334377
27 February 2025
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 8085701
6 February 2024
COI Inspection · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7857426
13 November 2023
In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7823970
13 November 2023
Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7823982
1 May 2023
Administrative Inspection · Construction Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7679770
17 January 2023
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7632820
11 January 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7619922
9 March 2022
Administrative Inspection · Hull Examination · Internal Structural Exam · Examination of Repairs · Drydock Exam · Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7408530
9 December 2021
Administrative Inspection · Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7365574
19 September 2020
Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7067698
12 August 2020
Damage Survey
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 7031090
20 July 2020
Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7011519
28 February 2020
Administrative Inspection · Hull Examination
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6917675
23 January 2020
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6894997
23 August 2019
COI Inspection · In-Service Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6792792
27 December 2018
Administrative Inspection · Inclining Experiment
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6603167
12 October 2018
Annual Inspection · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6560302
18 July 2018
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6483378
15 May 2018
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Lafayette · USCG Heartland District (CGD-H) · Activity 6415068
1 November 2017
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 6298894
5 October 2016
Annual Inspection · Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 6017745
29 June 2016
Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5923928
6 October 2015
Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 5736768
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 December 2021
Resolved
Port and STBD main deck fire extinguishing brackets are wasted and unservicable.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2021
Resolved 4 January 2022
Resolution: Cleared deficiencies based on photographic proof of new fire extinguisher brackets
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 15 December 2021
Resolved
No Monthly inspections of portable fire extinguishers
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2021
Resolved 4 January 2022
Resolution: Cleared deficiencies based on photographic proof of new monthly log
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 December 2021
Resolved
Life ring bouy line was dry rotted.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2021
Resolved 4 January 2022
Resolution: Cleared deficiencies based on photographic proof of new life ring line
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 December 2021
Resolved
STBD side fill vent wasted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2021
Resolved 4 January 2022
Resolution: Cleared deficiencies based on photographic proof of new STBD fill vent
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 9 December 2021
Resolved
Electrical MCT in watertight bulkhead was found loose and not water tight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2021
Resolved 4 January 2022
Resolution: Provided photo of repair.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 4 December 2020
Resolved
Forward PA system inoperable from bridge. Make repairs to satisfaction of marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2020
Resolved 15 December 2020
Resolution: vessel submited satisfactory objective evidence clearing def.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 December 2020
Resolved
All (03) fire hose nozzles were deteriorated and in need of replacement. Replace to the satisfaction of marine inspector.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2020
Resolved 4 January 2021
Resolution: Vessel rep submitted objective evidence (picture) clearing remaining def
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 December 2020
Resolved
Electrical distribution box in staboard lazarette had opening on top that could allow water intrusion. Repair to the satisfaction of marine inspector.
Action required: 10 - Deficiency Rectified
Due 28 December 2020
Resolved 4 December 2020
Resolution: Crew filled hole, sent objective evidence clearing deficiency to satisfaction of marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 16 September 2019
Resolved
Found 01 tonnage opening in the captains quarters blocked by lockers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 September 2019
Resolved 17 September 2019
Resolution: Locker blocking tonnage opening was moved.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 September 2019
Resolved
Found dead end wires located under the console on the bridge.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 September 2019
Resolved 17 September 2019
Resolution: Dead end wire was removed.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 15 May 2018
Resolved
Plastic Piping penetrations made through watertight bulkheads without the use of shutoff valves. IAW 46 CFR 182.720(d)(1)(i)(B).
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 15 May 2018
Resolved 18 July 2018
Resolution: Shutoff valves were installed IAW 46 CFR 182.720 (d)(1)
Engineering › Steering Gear System › Bracket/Clamp
Issued 27 October 2015
Resolved
Broken clamps on steering line. Replace clamps with new ones IAW 46CFR182.610.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 November 2015
Resolved 28 October 2015
Resolution: New clamps installed.
Accommodation/Occupational Safety › Occupational Safety › Portable Electric Equipment/Appliances
Issued 27 October 2015
Resolved
Air pump on top of sewage tank was no secured. Secure pump IAW 46CFR182.100.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 November 2015
Resolved 28 October 2015
Resolution: Electric pump secured to tank.