Records from 2016 to 2019. Most recent: inspection, 12 November 2019.
Inspection history · 5
12 November 2019
ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6848665
19 January 2019
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6612505
18 January 2019
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6612360
19 December 2016
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6060003
8 December 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6051051
Engineering › Fuel Oil Service System › Valve
Issued 19 December 2016
Resolved
Valve within fuel pump for cylinder number 5 was not operating.
Action required: 705 - Other - as specified
Due 19 December 2016
Resolved 19 December 2016
Resolution: Class report attests to repair and proper operation of fuel pump.
Construction/Loadline › Hull › Hull Plating
Issued 8 December 2016
Resolved
1299 - OTHER (LOAD LINES) - THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. STBD SIDE OF RUDDER HAS PATCH, CREW HAS NO KNOWLEDGE OF REPAIR OR DAMAGE. - 74 SOLAS (2014) I/11.A.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 December 2016
Resolution: DNV-GL claimed the issue was a result of the hull cleaning in OCT 2016.
Navigation › Collision/Grounding Avoidance › Navigation Bridge Visibility
Issued 8 December 2016
Resolved
0999 - OTHER (SAFETY IN GENERAL) - WINDOWS SHALL MEET THE FOLLOWING REQUIREMENTS-A CLEAR VIEW THROUGH AT LEAST TWO OF THE NAVIGATION BRIDGE FRONT WINDOWS AND, AN ADDITIONAL NUMBER OF CLEAR-VIEW WINDOWS SHALL BE PROVIDED AT ALL TIMES, REGARDLESS OF WEATHER CONDITIONS. WINDOW HEATERS INOPERABLE ON THIRD WINDOW INBOARD ON BOTH PORT AND STBD SIDE. - 74 SOLAS (2014) V/22.1.9.4.
Action required: 17 - Rectify deficiencies prior to departure
Due 27 February 2017
Resolved 14 December 2016
Resolution: Class report attests to repair of window heaters.
Engineering › Diesel Engine (propulsion-direct drive) › Cylinder Head
Issued 8 December 2016
Resolved
1410 - PROPULSION MAIN ENGINE - THE CONDITION OF THE SHIP AND ITS EQUIPMENT SHALL BE MAINTAINED TO CONFORM WITH THE PROVISIONS OF THE PRESENT REGULATIONS TO ENSURE THAT THE SHIP IN ALL RESPECTS WILL REMAIN FIT TO PROCEED TO SEA WITHOUT DANGER TO THE SHIP OR PERSONS ON BOARD. MULTIPLE F/W LEAKS FOUND ON MAIN ENGINE CYLINDER HEADS. - 74 SOLAS (2014) I/11.A.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 December 2016
Resolution: Class Report
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 8 December 2016
Resolved
1740 - OIL DISCH M/C SYSTEM - SYSTEM SHALL ENSURE ANY DISCHARGE OF OILY MIXTURE AUTOMATICALLY STOPS WHEN OIL CONTENT OF EFFLUENT EXCEEDS 15 PPM. MEPC.107(49) OIL FILTERING EQUIP. AND OIL CONTENT METER FAILED TO LOWER EFFLUENT BELOW 15 PPM. ADDITIONALLY, NOTED OCM SAMPLE LINE FAILED TO PROVIDE ENOUGH PRESSURE TO OCM DISCHARGE LINE TO INDICATE VALID SAMPLE SUPPLIED TO OCM. - 78 MARPOL (2011) I/14.7.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 17 December 2016
Resolution: Class Report
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 8 December 2016
Resolved
0999 - OTHER (SAFETY IN GENERAL) - CYLINDERS MUST ALWAYS BE SECURED AND, WHEN NOT IN USE, THEY MUST BE STOWER IN A RACK IN AN UPRIGHT POSITION, WITH THE VALVE PROTECTION CAP IN PLACE. CYLINDERS TIED WITH ROPE INSTEAD OF ON RACK, SOME WITHOUT CAPS SECURED. - 46 CFR 147.60(B)(1)
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Due 13 February 2017
Resolved 14 December 2016
Resolution: Class report attests to repair.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 8 December 2016
Resolved
0999 - OTHER (SAFETY IN GENERAL) - THE MAINTENANCE PLAN SHALL BE AVAILABLE FOR INSPECTION WHENEVER REQUIRED. MULTIPLE PORTABLE FIRE EXTINGUISHERS DID NOT HAVE INSPECTION TAGS, AND CREW COULD NOT PRODUCE MAINTENANCE RECORDS FOR INDIVIDUAL EXTINGUISHERS. - 74 SOLAS (2014) II-2/14.2.2.2.
Action required: 705 - Other - as specified
Due 8 December 2016
Resolved 8 December 2016