RENDEZVOUS

RENDEZVOUS is a 1971 passenger vessel (inspected). The Coast Guard has recorded 33 inspections since 2002, most recently in May 2026, along with 73 deficiencies and 2 casualty investigations between 2011 and 2017.

Records from 2002 to 2026. Most recent: inspection, 27 May 2026.

Built
1971
Last inspected
27 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH 5204
Flag
UNITED STATES
—
Maury page id
psix-126

Inspections, by type

…with no type recorded2
Years with a record 21 calendar years (2002–2026)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)40.6 ft × 13.2 ft × 6.4 ft
Registered tonnagegross 22 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGLACIER PARK BOAT BUILDERS · KALISPELL, MT, UNITED STATES · built 1971
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portMORAN, WY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 7 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it18 - Simplified, Net Ton
22 - Simplified, Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 33

27 May 2026 Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8319444
28 May 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8106640
29 May 2024 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7922808
31 May 2023 COI Inspection · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7684661
12 May 2022 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7449171
9 April 2021 Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7172028
7 October 2020 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7073513
3 August 2020 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7023593
7 June 2019 Annual Inspection · Deficiency Check · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6690453
6 June 2018 Administrative Inspection · MARPOL Annex VI Survey · COI Inspection · Hull Examination · Deficiency Check · Internal Structural Exam · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6429936
26 February 2018 Examination of Repairs
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6363208
11 August 2017 Spot Check · Internal Structural Exam · Hull Examination · Administrative Inspection · Plan Review "T" Boat · Damage Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6242221
11 August 2017 Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6242556
13 July 2017 Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6211879
6 June 2017 Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 6142952
16 May 2016 Deficiency Check · Special · DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 5878680
6 August 2014 Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4945779
9 June 2014 DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4874174
14 June 2012 Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4358445
10 May 2012 Damage Survey · COI Inspection · DAPI Audit
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4307563
8 August 2011 Administrative Inspection · Damage Survey
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4146976
7 August 2011 Type not recorded
No type recorded · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 4146100
7 January 2011 Administrative Inspection
Administrative · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 3922507
20 July 2009 Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3540401
13 May 2009 Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3474012
21 November 2008 Drydock Extension
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3367337
2 June 2008 Deficiency Check · Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 3213779
4 June 2007 COI Inspection
Physical examination · Marine Safety Detachment Peoria · USCG Heartland District (CGD-H) · Activity 2951074
1 June 2005 Re-Inspection
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 2375826
15 June 2004 Hull Examination · Annual Inspection
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 2099118
4 June 2003 Annual Inspection
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1816437
29 October 2002 Deficiency Check
Physical examination · MSD PEORIA · USCG Heartland District (CGD-H) · Activity 1697945
16 July 2002 COI Inspection
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1639383

Deficiency record · 73

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 May 2023 Resolved
Machinery must be free of leaks. Inspection found coolant leak on the starboard engine on the inboard cooling flex pipe hose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 1 June 2023
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 May 2023 Resolved
A vessel must be provided with satisfactory arrangement for draining any watertight compartment. Inspection found the passenger compartment auto bilge pump did not have automatic capability.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 1 June 2023
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 May 2023 Resolved
A vessel must be provide with arrangement for draining any watertight compartment. Inspection found forward machinery bilge pump missing hose clamp on discharge hose.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 June 2023
Resolved 1 June 2023
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 8 June 2021 Resolved
Replace damaged raw water hose on starboard main engine.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 10 June 2021
Resolution: Received email documentation sufficient to clear def.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 June 2019 Resolved
Repair or replace the leaking port MDE raw water pump. While operating the vessel, ensure the Master monitors the vessel’s water temperature to prevent the vessel from overheating should a total pump failure occur.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2019
Resolved 3 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 June 2019 Resolved
Replace the damaged port MDE transmission oil cooler hose. The outer cover of the hose appears to have been chewed by a varmint.
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2019
Resolved 3 July 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 7 June 2019 Resolved
Replace the deteriorated upper heat exchanger coolant hose.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2019
Resolved 3 July 2019
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 7 June 2019 Resolved
Replace the frayed manual pull cable on the installed fire suppression system.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 July 2019
Resolved 19 July 2019
Resolution: Cable replaced
Fire Fighting › Fixed Gas Fire Extinguishing System › Quantity of Gas
Issued 6 June 2018 Resolved
Firestop the wire penetration in the aft, port side bulkhead of the cabin void.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 3 July 2018
Engineering › Diesel Engine (propulsion-reduction gear) › Seal
Issued 6 June 2018 Resolved
Repair as necessary the port MDE slight fuel pump leak.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 3 July 2018
Engineering › Bilge Water Management System › Pump
Issued 6 June 2018 Resolved
Ensure the aft E/R bilge pump discharges in the auto mode, the pumps runs but will not discharge water.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 3 July 2018
Lifesaving › Emergency Outfit › Lifeline and Belt/Harness
Issued 6 June 2018 Resolved
Properly install the new SOS rescue sling and ensure the crew is properly trained on how to deploy the new system.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 July 2018
Resolved 3 July 2018
Engineering › Steering Gear System › Power Unit
Issued 6 June 2018 Resolved
Determine the cause of the helm catching and clicking when it is placed hard over to the port or stbd, and repair as necessary.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 July 2018
Resolved 3 July 2018
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 11 August 2017 Resolved
The vessel shall not be operated in passenger service until the damage to the hull, machinery and running gear as a result of the vessel grounding on August 11, 2017 is repaired to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 20 May 2019
Resolved 21 May 2018
Resolution: Both propellr shafts renewed. Damage to hull repaired. Damage to running gear repaired. Both struts, propellers, rudders and shafts renewed.
Fire Fighting › Combustible Materials › Insulation
Issued 6 June 2017 Resolved
Replace the damaged port engine cover insulation.
Due 7 July 2017
Resolved 13 July 2017
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 31 May 2016 Resolved
Ensure the first aid kit has the proper contents and that the items are not expired.
Condition: Improper/Lack of Maintenance
Due 30 June 2016
Resolved 30 June 2016
Construction/Loadline › Structures › Superstructure
Issued 31 May 2016 Resolved
Determine the source of the water leak in the aft cabin, overhead, area and repair as necessary.
Condition: Improper/Lack of Maintenance
Due 30 June 2016
Resolved 30 June 2016
Construction/Loadline › Structures › Superstructure
Issued 31 May 2016 Resolved
Reseal the cabin top search light base.
Condition: Improper/Lack of Maintenance
Due 30 June 2016
Resolved 30 June 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 31 May 2016 Resolved
Properly secure the exposed wires on the aft cabin area heater
Condition: Improper Installation
Due 30 June 2016
Resolved 30 June 2016
Lifesaving › Launching Appliances › Winch
Issued 31 May 2016 Resolved
Properly align the lifesaving rescue davit rope to ensure it is routed around the pulley.
Condition: Improper Installation
Due 30 June 2016
Resolved 30 June 2016
Electrical › Electric Generation Source (service) › Generator
Issued 31 May 2016 Resolved
Replace the port engine, operating station, volt gauge.
Due 30 June 2016
Resolved 30 June 2016
Engineering › Freshwater System (jacketwater cooling) › Hose
Issued 9 June 2014 Resolved
Replace port MDE raw water hose where it enters the exhaust piping.
Action required: 705 - Other - as specified
Due 9 July 2014
Resolved 6 August 2014
Engineering › Diesel Engine (propulsion-direct drive) › Piping (exhaust)
Issued 9 June 2014 Resolved
Tighten loose exhaust hose clamps on starboard aft MDE exhaust hose.
Action required: 705 - Other - as specified
Due 9 July 2014
Resolved 10 June 2014
Operations/Management › Bilge/Bilge System Management › Control of Excess Water
Issued 9 June 2014 Resolved
Clean debris out of all E/R limber holes.
Action required: 705 - Other - as specified
Due 9 July 2014
Resolved 6 August 2014
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 9 June 2014 Resolved
Conduct and document survival craft weekly & monthly maintenance/inspections as required by 46 CFR 185.720 & 722 (weekly visuals & monthly as per manufactures instructions).
Action required: 705 - Other - as specified
Due 9 July 2014
Resolved 6 August 2014
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 14 June 2012 Resolved
Install a mounting bracket for the accommodation space, B-II, portable fire extinguisher. Do to space limitations, the extinguisher may be mounted in the forward cabin void providing a sign (fire extinguisher inside) is posted on the door.
Due 14 July 2012
Resolved 24 July 2012
Documentation › Markings/Placards › Lifejacket Placard
Issued 10 May 2012 Resolved
Update or replace the lifejacket donning instructions. Instructions were onboard but were starting to deteriorate due to weather.
Due 28 June 2012
Resolved 25 June 2012
Documentation › Markings/Placards › Official Number (US)
Issued 10 May 2012 Resolved
Ensure the vessel's hailing port is displayed on the vessel's stern and the official number is permanently affixed to an internal structural member. Items were already on order.
Due 28 June 2012
Resolved 25 June 2012
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 10 May 2012 Resolved
Ensure the first aid kit meets the requirements of 33CFR160-041. Item was already on order.
Due 28 June 2012
Resolved 25 June 2012
Fire Fighting › Combustible Materials › Insulation
Issued 10 May 2012 Resolved
Repair or replace the port hatch cover insulation. Company was aware of the issue and was already researching a source of supply.
Due 28 June 2012
Resolved 25 June 2012
Engineering › Freshwater System (cylinder head cooling) › Pump
Issued 10 May 2012 Resolved
Repair or replace the port MDE raw water pump. Pump has a slight leak.
Due 1 January 2013
Resolved 3 June 2013
Resolution: Water pump replaced July 2012. Cleared electronically. Visually checked during 2013 inspection.
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 10 May 2012 Resolved
Ensure the company has negative pre employment test results before placing the crew in safety sensitive positions.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 June 2012
Electrical › Electrical Distribution System (service) › Cable
Issued 13 May 2009 Resolved
On the Public Address System wiring, secure with metal clips/brackets wiring above stern cabin doorway & seal connection near starboard side speaker.
Condition: Improper/Lack of Maintenance
Due 4 July 2009
Resolved 2 June 2010
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 13 May 2009 Resolved
Update emergency procedures to include throwing of a buoyant object immediately upon man over board.
Condition: Unknown
Due 4 July 2009
Resolved 2 June 2010
Communications › Audible Communications › Horn/Whistle
Issued 13 May 2009 Resolved
Properly mount the vessel's horn.
Condition: Improper/Lack of Maintenance
Due 4 July 2009
Resolved 7 May 2010
Resolution: Vessel''s horn properly mounted.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 May 2009 Resolved
Properly wire mast headlight to ensure the display of an anchor light.
Condition: Unknown
Due 4 July 2009
Resolved 7 May 2010
Resolution: Mast headlight wired to display anchor light.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 May 2009 Resolved
Add instructions to the vessel's first aid kit.
Condition: Improper/Lack of Maintenance
Due 4 July 2009
Resolved 2 June 2010
Fire Fighting › Fire Bucket › Lanyard
Issued 13 May 2009 Resolved
Ensure all fire buckets are tethered with a lanyard long enough to reach the water.
Condition: Placed in Improper Service
Due 4 July 2009
Resolved 2 June 2010
Communications › Alarms/Indicators › Bilge Alarm
Issued 13 May 2009 Resolved
Prove proper operation of the cabin void high level bilge alarm.
Condition: Unknown
Due 4 July 2009
Resolved 2 June 2010
Lifesaving › Inflatable Liferafts › Servicing
Issued 13 May 2009 Resolved
Ensure monthly inspections are conducted and logged on the inflatable life raft as per the manufactures maintenance manual.
Condition: Improper/Lack of Maintenance
Due 4 July 2009
Resolved 2 June 2010
Engineering › Fuel Oil Service System › Piping
Issued 13 May 2009 Resolved
Electrically bond the fuel tank fill spout to the fuel tank.
Condition: Placed in Improper Service
Due 4 July 2009
Resolved 7 May 2010
Resolution: fuel tank fill spout electrically bonded to the fuel tank.
Navigation › Collision/Grounding Avoidance › Echo-sounding Device
Issued 13 May 2009 Resolved
Properly install the depth sounder transducer and wire and remove all transducer oil from cabin void bilge.
Condition: Improper Installation
Due 4 July 2009
Resolved 7 May 2010
Resolution: Depth sounder transducer and wire properly installed. Cabin void bilge free of oil.
Fire Fighting › Combustible Materials › Insulation
Issued 13 May 2009 Resolved
Fire stop the port engine room bulkhead at the upper side shell & all areas where the combustible foam has been applied.
Condition: Unknown
Due 4 July 2009
Resolved 2 June 2010
Lifesaving › Hand Flares › Quantity
Issued 13 May 2009 Resolved
Add two more approved flares to signal distress kit.
Condition: Improper/Lack of Maintenance
Due 4 July 2009
Resolved 2 June 2010
Navigation › Piloting/Steering › Magnetic Compass
Issued 13 May 2009 Resolved
Install a marine compass.
Condition: Placed in Improper Service
Due 4 July 2009
Resolved 2 June 2010
Engineering › Freshwater System (air cooling) › Hose
Issued 13 May 2009 Resolved
Repair starboard engine antifreeze leak at the front of engine.
Condition: Unknown
Due 4 July 2009
Resolved 7 May 2010
Engineering › Fuel Oil Service System › Hose
Issued 13 May 2009 Resolved
Replace starboard engine fuel hose connecting fuel line to engine fuel pump.
Condition: Unknown
Due 4 July 2009
Resolved 2 June 2010
Electrical › Electric Supply System (service) › Battery Installation
Issued 13 May 2009 Resolved
Secure batteries to deck.
Condition: Unknown
Due 4 July 2009
Resolved 7 May 2010
Resolution: Batteries secured.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 13 May 2009 Resolved
Install 5/16 inch, 3 to 6 foot long lanyard, to light float (current lanyard is too bulky and not long enough).
Condition: Unknown
Due 4 July 2009
Resolved 2 June 2010
Fire Fighting › Ventilation Systems › Ducts
Issued 13 May 2009 Resolved
Properly vent cabin void space. Currently configured with two supply vents at the aft bulkhead and no exhaust vents. Void needs to have vents fore and aft ensuring a minimum of one supply and one exhaust vent.
Condition: Improper/Lack of Maintenance
Due 4 July 2009
Resolved 2 June 2010
Navigation › Piloting/Steering › Marine Charts
Issued 13 May 2009 Resolved
Ensure chart of lake on each vessel.
Condition: Unknown
Due 4 July 2009
Resolved 2 June 2010
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 13 May 2009 Resolved
Ensure Drug & Alcohol program is in compliance with 46 CFR Parts 4 and 16, 49 CFR 40 and 33 CFR 95.
Condition: Improper/Lack of Maintenance
Due 4 July 2009
Resolved 2 June 2010
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 22 May 2008 Resolved
Amend company's Drug and alcohol program to include preemployment testing and post casualty testing for marine crew.
Condition: Unknown
Due 5 July 2008
Resolved 20 June 2008
Resolution: Amended
Documentation › Markings/Placards › Warning Signs
Issued 22 May 2008 Resolved
Post emergency instruction placard.
Condition: Unknown
Due 6 July 2008
Resolved 2 June 2010
Documentation › Markings/Placards › Warning Signs
Issued 22 May 2008 Resolved
Display Emergency Broadcast Placrd.
Due 6 June 2008
Resolved 6 June 2008
Resolution: resolved
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 22 May 2008 Resolved
provide a CG approved water light with lanyat=rd and clip prior to night ops.
Action required: 705 - Other - as specified
Resolved 2 June 2010
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 May 2008 Resolved
Provide 60 foot life line. Vessel currently has 50 feet.
Action required: 705 - Other - as specified
Resolved 2 June 2010
Engineering › Diesel Engine (propulsion-reduction gear) › Distributor (fuel injection)
Issued 22 May 2008 Resolved
Repair fuel leak on fuel line return on port engine prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2008
Resolution: repaired with new line.
Engineering › Sea-water System (primary cooling) › Piping
Issued 22 May 2008 Resolved
Double clamp hoses as indicated during inspection.
Due 3 June 2008
Resolved 3 June 2008
Electrical › Electric Supply System (service) › Battery Installation
Issued 22 May 2008 Resolved
Tighten/ clean loose batttery terminal.
Due 3 June 2008
Resolved 3 June 2008
Resolution: Cleaned and tightened.
Engineering › Bilge Water Management System › Strainer
Issued 22 May 2008 Resolved
Clean bilges especilally in areas around bilge pump/strainers.
Due 3 June 2008
Resolved 3 June 2008
Resolution: Cleaned debris.
Communications › Public Address System › Loudspeaker
Issued 12 June 2007 Resolved
Condition: Unknown
Due 12 July 2007
Resolved 13 June 2007
Communications › Radio Communications › VHF Radiotelephone
Issued 12 June 2007 Resolved
Radio on board can not transmit to base in all areas of the lake, install a greater wattage out put or a repeater for base.
Due 31 July 2007
Resolved 23 July 2007
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 4 June 2007 Resolved
replace damaged life jacket, 6 adults and 3 children
Condition: Improper/Lack of Maintenance
Due 12 June 2007
Resolved 13 June 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Bearing
Issued 15 June 2004 Resolved
Replace both cutlass bearings on engines prior to the carriage of passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 June 2006
Resolved 6 June 2006
Engineering › Diesel Engine (propulsion-reduction gear) › Bedplate
Issued 15 June 2004 Resolved
Repair motor mounts on both engines.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2006
Resolved 3 June 2006
Electrical › Electric Generation Source (service) › Circuit Breaker
Issued 15 June 2004 Resolved
Move all circuit breakers as close as possible to the batteries and add covers to prevent accidental shorts.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 3 June 2006
Resolved 3 June 2006
Engineering › Bilge Water Management System
Issued 4 June 2003 Resolved
Provide manual bilge pump. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Due 17 June 2003
Resolved 15 July 2003
Resolution: Bilge pump added by company.
Engineering › Bilge Water Management System
Issued 4 June 2003 Resolved
Provide operational bilge pump high water alarm. LEGACY COMPONENT DESC: Pump
Condition: Unknown
Due 17 June 2003
Resolved 15 July 2003
Resolution: Bilge pump alarm replaced.
Electrical › Electrical Distribution System (service)
Issued 16 July 2002 Resolved
Properly support wiring in voids. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 16 August 2002
Resolved 12 August 2002
Resolution: Wire supports installed in void spaces.
Engineering › Diesel Engine (propulsion-direct drive)
Issued 16 July 2002 Resolved
Remove excess fuel hoses to main engines and properly support.
Due 16 August 2002
Resolved 12 August 2002
Resolution: Shorter fuel lines procured and installed on board vessel.
Engineering › Bilge Water Management System
Issued 16 July 2002 Resolved
Provide visual indicator at the operator station for automatic bilge pump. LEGACY COMPONENT DESC: Pump
Condition: Placed in Improper Service
Due 16 August 2002
Resolved 12 August 2002
Resolution: Bilge visual indicators installed at operator station.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 16 July 2002 Resolved
Provide non-combustable trash cans.
Condition: Unknown
Due 16 August 2002
Resolved 12 August 2002
Resolution: Non-combustible trash cans procured and installed on vessel.

Casualty record · 2

7 August 2011Routine · role: Involved in a Marine Casualty · activity 4146100
11 August 2017Routine · role: Involved in a Marine Casualty · activity 6242556
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.