MAURY USCG vessel records
← All vessels

LOGAN

Built
1974
Last inspected
13 August 2020
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Inspection record

Last inspected 13 August 2020
…with no type recorded3
Operational controls None recorded without a removal date
Years with a record 9 calendar years (1999–2020)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDB3865
126077
Flag
CANADA
Maury page id
psix-126077

Documentation record

Tonnage as PSIX records it9 - Regulatory (Subpart C or D), Net Ton
23 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 16 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 16

13 August 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7032202
24 March 2020 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6931064
28 February 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7032062
5 February 2020 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6903615
30 January 2019 Initial Certification · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6617673
15 October 2012 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4464704
9 October 2012 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4460802
6 December 2011 Uninspected Other
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4198853
29 April 2011 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4004355
31 March 2010 Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3820291
1 May 2008 DAPI Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3200015
23 March 2007 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2895431
12 March 2007 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2886653
25 January 2007 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2861856
4 December 2006 Uninspected Other · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2833995
5 November 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 129186

Deficiency record · 13

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 February 2020 Resolved
*Prior to vessel operations* Prove proper operation of generator and fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2020
Resolution: Gen and fire pump operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 February 2020 Resolved
Properly fasten one bolt on port side rudder.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2020
Resolution: Bolt fastened.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 February 2020 Resolved
Provide life ring with water light.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2020
Resolution: Life ring light installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 February 2020 Resolved
Re-weld broken support on stbd aft fender.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2020
Resolution: Fender re-welded.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 February 2020 Resolved
Re-fasten forward fuel tank flame screen to goose neck.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2020
Resolution: Flame screen installed.
Documentation › Logs/Records › Drug Test Records
Issued 31 March 2010 Resolved
Supervisors have no proof of 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR 16.401.
Due 30 April 2010
Resolved 4 June 2010
Resolution: SEC San Diego DAPI received 1 hour EAP training documentation from company''''s DER.
Documentation › Markings/Placards › Vessel Number (state)
Issued 4 December 2006 Resolved
provide vessel name port and starboard bow
Due 4 January 2007
Resolved 28 August 2007
Resolution: installed
Navigation › Piloting/Steering › Marine Charts
Issued 4 December 2006 Resolved
provide updated charts and pubs from operating area.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2007
Resolution: updated
Communications › Alarms/Indicators › General Alarm
Issued 4 December 2006 Resolved
Install general alarm iaw 46CFR27.201
Due 28 January 2007
Resolved 12 March 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 4 December 2006 Resolved
Install fixed or semi fixed fire extinguishing system iaw 46CFR27.303
Due 28 January 2007
Resolved 28 August 2007
Resolution: B-V installed
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 4 December 2006 Resolved
Install fixed fire detction system iaw 46CFR27.203
Due 28 January 2007
Resolved 17 October 2007
Resolution: COTP SDCMS waived for inland waters.
Fire Fighting › Fire Pumps › Arrangement
Issued 4 December 2006 Resolved
Install fire pump iaw 46CFR27.301
Due 28 January 2007
Resolved 23 March 2007
Resolution: portable installed
Engineering › Fuel Oil Service System › Valve
Issued 4 December 2006 Resolved
Install remote fuel shut-off valves at supply.
Due 28 January 2007
Resolved 23 March 2007

Ownership record