MAURY USCG vessel records Sign in
← All vessels

LOGAN

LOGAN is a 1974 towing vessel. The Coast Guard has recorded 16 inspections since 1999, most recently in August 2020, along with 13 deficiencies.

Records from 1999 to 2020. Most recent: inspection, 13 August 2020.

Built
1974
Last inspected
13 August 2020
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDB3865
126077
Flag
CANADA
366892160 (licence lapsed)
Maury page id
psix-126077

Inspections, by type

…with no type recorded3
Years with a record 9 calendar years (1999–2020)
The 16 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it9 - Regulatory (Subpart C or D), Net Ton
23 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WDB3865MMSI 366892160 · expired · compulsorily equipped · granted 10 April 2013, cancelled 15 July 2023
WAA9417MMSI not assigned · expired · voluntarily equipped · granted 14 April 1994, cancelled 22 August 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 16

13 August 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7032202
24 March 2020 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6931064
28 February 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7032062
5 February 2020 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6903615
30 January 2019 Initial Certification · Administrative Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6617673
15 October 2012 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4464704
9 October 2012 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4460802
6 December 2011 Uninspected Other
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4198853
29 April 2011 DAPI Audit
Administrative · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4004355
31 March 2010 Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 3820291
1 May 2008 DAPI Audit
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3200015
23 March 2007 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2895431
12 March 2007 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2886653
25 January 2007 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2861856
4 December 2006 Uninspected Other · MTSA Verification
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2833995
5 November 1999 Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 129186

Deficiency record · 13

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 February 2020 Resolved
*Prior to vessel operations* Prove proper operation of generator and fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2020
Resolution: Gen and fire pump operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 February 2020 Resolved
Properly fasten one bolt on port side rudder.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2020
Resolution: Bolt fastened.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 February 2020 Resolved
Provide life ring with water light.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2020
Resolution: Life ring light installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 February 2020 Resolved
Re-weld broken support on stbd aft fender.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2020
Resolution: Fender re-welded.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 February 2020 Resolved
Re-fasten forward fuel tank flame screen to goose neck.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2020
Resolution: Flame screen installed.
Documentation › Logs/Records › Drug Test Records
Issued 31 March 2010 Resolved
Supervisors have no proof of 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR 16.401.
Due 30 April 2010
Resolved 4 June 2010
Resolution: SEC San Diego DAPI received 1 hour EAP training documentation from company''''s DER.
Documentation › Markings/Placards › Vessel Number (state)
Issued 4 December 2006 Resolved
provide vessel name port and starboard bow
Due 4 January 2007
Resolved 28 August 2007
Resolution: installed
Navigation › Piloting/Steering › Marine Charts
Issued 4 December 2006 Resolved
provide updated charts and pubs from operating area.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2007
Resolution: updated
Communications › Alarms/Indicators › General Alarm
Issued 4 December 2006 Resolved
Install general alarm iaw 46CFR27.201
Due 28 January 2007
Resolved 12 March 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 4 December 2006 Resolved
Install fixed or semi fixed fire extinguishing system iaw 46CFR27.303
Due 28 January 2007
Resolved 28 August 2007
Resolution: B-V installed
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 4 December 2006 Resolved
Install fixed fire detction system iaw 46CFR27.203
Due 28 January 2007
Resolved 17 October 2007
Resolution: COTP SDCMS waived for inland waters.
Fire Fighting › Fire Pumps › Arrangement
Issued 4 December 2006 Resolved
Install fire pump iaw 46CFR27.301
Due 28 January 2007
Resolved 23 March 2007
Resolution: portable installed
Engineering › Fuel Oil Service System › Valve
Issued 4 December 2006 Resolved
Install remote fuel shut-off valves at supply.
Due 28 January 2007
Resolved 23 March 2007

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.