This record may be incomplete: the most recent inspection recorded for this vessel was 6 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Towing Vessel class in Maury's sources begin in 1980.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it9 - Regulatory (Subpart C or D), Net Ton 23 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel
Behind this panel: 16 inspections, each with its date, unit and type; 13 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 16
13 August 2020Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7032202
24 March 2020In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6931064
28 February 2020Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7032062
5 February 2020Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6903615
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 5 February 2020Resolved
*Prior to vessel operations* Prove proper operation of generator and fire pump.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 February 2020
Resolution: Gen and fire pump operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 February 2020Resolved
Properly fasten one bolt on port side rudder.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2020
Resolution: Bolt fastened.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 5 February 2020Resolved
Provide life ring with water light.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2020
Resolution: Life ring light installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 5 February 2020Resolved
Re-weld broken support on stbd aft fender.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2020
Resolution: Fender re-welded.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 February 2020Resolved
Re-fasten forward fuel tank flame screen to goose neck.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 6 February 2020
Resolution: Flame screen installed.
Documentation › Logs/Records › Drug Test Records
Issued 31 March 2010Resolved
Supervisors have no proof of 1 hr of Employee Assistance Program (EAP) training as required by 46 CFR 16.401.
Due 30 April 2010
Resolved 4 June 2010
Resolution: SEC San Diego DAPI received 1 hour EAP training documentation from company''''s DER.
Documentation › Markings/Placards › Vessel Number (state)
Issued 4 December 2006Resolved
provide vessel name port and starboard bow
Due 4 January 2007
Resolved 28 August 2007
Resolution: installed
Navigation › Piloting/Steering › Marine Charts
Issued 4 December 2006Resolved
provide updated charts and pubs from operating area.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 25 January 2007
Resolution: updated
Communications › Alarms/Indicators › General Alarm
Issued 4 December 2006Resolved
Install general alarm iaw 46CFR27.201
Due 28 January 2007
Resolved 12 March 2007
Fire Fighting › Fixed CO2 Fire Extinguishing System › Location
Issued 4 December 2006Resolved
Install fixed or semi fixed fire extinguishing system iaw 46CFR27.303
Due 28 January 2007
Resolved 28 August 2007
Resolution: B-V installed
Fire Fighting › Fixed Fire Detection System › Arrangement
Issued 4 December 2006Resolved
Install fixed fire detction system iaw 46CFR27.203
Due 28 January 2007
Resolved 17 October 2007
Resolution: COTP SDCMS waived for inland waters.
Fire Fighting › Fire Pumps › Arrangement
Issued 4 December 2006Resolved
Install fire pump iaw 46CFR27.301
Due 28 January 2007
Resolved 23 March 2007
Resolution: portable installed
Engineering › Fuel Oil Service System › Valve
Issued 4 December 2006Resolved
Install remote fuel shut-off valves at supply.
Due 28 January 2007
Resolved 23 March 2007
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.