MAURY USCG vessel records
← All vessels

SSI DEFIANT

SSI DEFIANT is a 2013 freight ship. The Coast Guard has recorded 12 inspections since 2021, most recently in September 2024, along with 23 deficiencies and 5 operational controls, 1 with no removal date recorded.

Records from 2021 to 2024. Most recent: operational control imposed, 29 September 2024.

Built
2013
Last inspected
27 September 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
1 with no removal date recorded

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 27 September 2024
…with no type recorded4
Operational controls 1 with no removal date recorded
Years with a record 4 calendar years (2021–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9603116
V7A5690
1261093
Flag
LIBERIA
Maury page id
psix-1261093

Documentation record

Tonnage as PSIX records it32987 - Convention (Subpart B), Gross Ton
19236 - Convention (Subpart B), Net Ton
56489 - Dead Weight, Metric Ton
67681 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 1

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

E. STROUD Unclassified · MISLE 343716 · 20 May 2021 · activity 7206142

Inspection history · 12

27 September 2024 PSC B · MARPOL Annex I Examination · ISM Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8010009
26 September 2024 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8010815
26 September 2024 Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8011481
10 May 2024 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7909235
6 May 2024 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7907577
13 October 2023 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7803915
15 April 2022 Type not recorded
No type recorded · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7431854
7 June 2021 In-Service Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7218261
20 May 2021 Deficiency Check · Damage Survey
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7200922
20 May 2021 Type not recorded
No type recorded · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7206142
18 May 2021 Administrative Inspection
Administrative · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7200057
17 May 2021 PSC B
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7188312

Deficiency record · 23

15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 28 September 2024 Resolved
The company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations and with any additional requirements which may be established by the company. The technical and operational nature of deficiencies 02, 03, 04,05, 06, 07, 08, 09,10 provide objective evidence of a serious failure of the implementation of the ISM code. In addition PSCO observed the vessel failed to follow their SMS reporting and response procedures following pollution spills on 24 and 25 September 2024 as required by ISM Code 9.1. An external audit report satisfactory to the COTP must be submitted prior to clearance of this deficiency. 74 SOLAS 20 IX/3.1 ISM Code 10.1
Action required: 30 - Ship detained
Resolved 22 October 2024
Resolution: Class submitted an SMS audit. All sat. Uploaded into documents
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 28 September 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present Convention to ensure that the ship in all respects will remain fit to proceed to sea without presenting an unreasonable threat or harm to the marine environment. Several witnesses observed and reported a sheen emanating from the vessel. PSCO observed an oily residue within one of the vessel's overboard discharge pipes on the inboard side. PSCO also observed oil on wash water pipping. MARPOL Annex I Reg 6.4.1
Action required: 30 - Ship detained
Resolved 22 October 2024
Resolution: Class submitted survey report attesting that all systems they listed were flushed and cleaned and engine testing was witnessed by IMD and PSC. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 September 2024 Resolved
The machinery, boilers, and other pressure vessels, associated pipping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed persons on-board. PSCO observed a steam pipe leak on boiler, located in engine room. 74 SOLAS 20 II-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2024
Resolution: Class submitted survey report attesting to steam leak repair. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 September 2024 Resolved
The machinery, boilers, and other pressure vessels, associated pipping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed persons on-board. PSCO observed diesel oil purifier inoperable. 74 SOLAS 20 11-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 October 2024
Resolution: Class provided survey report attesting that the oil purifier in question had be previously decommissioned by the previous class society (BV)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 September 2024 Resolved
All electrical apparatus shall be so constructed and so installed as not to cause injury when handled or touched in the normal manner. PSCO observed several electrical display units missing covers and wrapped with electrical tape throughout the engine room. 74 SOLAS 20 11-1/45.1.3
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2024
Resolution: Class provided survey report to attest to missing electrical displays were repaired. All sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 28 September 2024 Resolved
All electrical cables and wiring external to equipment shall be at least of a flame-retardant type and shall be so installed as not to impair their original flame-retarding properties. PSCO observed exposed wiring in the purifier room, in the engine room and on main cargo deck. 74 SOLAS 20 11-1/45.5.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2024
Resolution: Class provided survey report attesting to the exposed wiring in the purifier and engine room and main cargo deck. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 28 September 2024 Resolved
Fire Fighting systems and appliances shall be kept in good working order and readily available for immediate use. PSCO observed foam applicator device by the incinerator empty. 74 SOLAS 20 11-2/14.2.1.2
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2024
Resolution: Class provided survey report attesting that the foam applicator jug was refilled. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 September 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons on board. PSCO observed low hydraulic fluid level in the emergency steering gear space. 74 SOLAS 20 1/11 (a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2024
Resolution: Class provided survey report attesting that the emergency hydraulic fluid reservoir in the steering space was filled to the full level. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 September 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons on board. PSCO was told by vessel’s Superintendent and Master on 27SEP24, that the cause of the oil in the PS wash water tank may be a crack within the fuel oil tank adjacent to the PS wash water tank. PSCO visually inspected the PS wash water tank and verified the oil was present. Vessel's crew suspects that the cause of the oil in the PS wash water tank may be caused by a crack within the tank fuel oil tank adjacent to the PS wash water tank. 74 SOLAS 20 1/11(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2024
Resolution: Class provided survey report attesting that there was no crack in fuel tank. Fuel was leaking out of a flange, which was blanked off. All sat.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 September 2024 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to ship or persons on board. A diver observed fishing net and line wrapped around the stern seal. 74 SOLAS 20 1/11 (a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2024
Resolution: Deficiency was corrected as per RO report (see attachment).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 September 2024 Resolved
The machinery, boilers, and other pressure vessels, associated pipping systems and fittings shall be of a design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to a minimum any danger to persons on-board. [name withheld] reported a loss of propulsion while inbound to the Port of Baltimore which required the vessel to enact emergency operations to anchor safety. The cause of of the loss of propulsion has yet to be determined. 74 SOLAS 20 11-1/26.1
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 October 2024
Resolution: Deficiency was corrected as per RO report (see attachment).
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo operation
Issued 10 May 2024 Resolved
The carraiage of dangerous goods in solid form in bulk shall be in compliance with the relevant provisions of the IMSBC Code, as defines in regulation VI/1-1.1. Where a solid bulk cargo is specifically listed in appendix 1 to this code, it shall be transported in accordance with the provisions in its schedual in addition to the provisions in sections 1 to 10 and 11.1.1 of this code. PSCO observed multiple electrical discrepencies in lighting connections in hazardous area of the cargo block while vessel was loading coal. General requirements for coal section 2.2 of IMSBC require electrical cables and components in the cargo area to be free of defect prior to loading. Vessel must rectify prior to cargo operations. 74 SOLAS (20) VII/7-5, IMSBC Code 1.4.1, 17abc.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2024
Resolved 10 May 2024
Resolution: Received, reviewed and accepted class report from BV attesting to the operational readiness of the of the deck electrical installation.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 10 May 2024 Resolved
The purpose of this regulation is to prevent the ignition of cobustible materials or flammable liquids. PSCO observed excessive amounts of fuel oil in the duct keel. 74 SOLAS (20) II-2/4.1, 17ac.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 17 May 2024
Resolved 10 May 2024
Resolution: Received, reviewed and accepted class report from BV attesting to the duct keel being ckeaned and repaies to the failed valve assembly.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 13 October 2023 Resolved
Each survival craft shall be stowed in a state of continuous readiness so that two crew members can launch in less than 5 minutes. PSCO waited more than 5 minutes for two crew members to start rescue boat engine, but it would not start. 74 SOLAS (2020) III/13.1.3, Code 17, PTD
Action required: 17 - Rectify deficiencies prior to departure
Due 13 October 2023
Resolved 20 October 2023
Resolution: Received, reviewed and accepted class report / proper documentation from [name withheld] stating the deficienciency was rectified.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 October 2023 Resolved
Cargo spaces on cargo ships shall be protected by a fixed CO2 system complying with the FSS Code. The piping for the distribution of CO2 shall have system flow calculations performed using a calculation technique acceptable to the administration. PSCO witnessed repairs to CO2 line on CH #5 portside with non-matching pipe sizing inserted intermittently with fillet welds. Prove acceptance of arrangement to cognizant Captain of the Port. 74 SOLAS (2020) II-2/7.1.2, FSS Code 5.2.1.2.1, Code 17, PTD
Action required: 17 - Rectify deficiencies prior to departure
Due 13 October 2023
Resolved 20 October 2023
Resolution: Received, reviewed and accepted class report / proper documentation from [name withheld] stating the deficienciency was rectified.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 13 October 2023 Resolved
The utilization of other flammable oils employed under pressure in power transmission systems shall be such as to ensure the safety of the ship and persons on board. PSCO witnessed CH #2 had temporary soft patch on hydraulic line on deck, causing leaks of hydraulic oil. 74 SOLAS (2020) II-2/4.2.4, Code 17, PTD
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 October 2023
Resolution: Received, reviewed and accepted class report / proper documentation from [name withheld] stating the deficienciency was rectified.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 October 2023 Resolved
Electrical installations shall be such that the safety of the crew and ship shall be ensured. PSCO witnessed numerous wasted electrical boxes, unsecured electrical wiring, and improperly installed electrical equipment on deck in cargo area. 74 SOLAS (2020) II-1/40.1.3, Code 16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2023
Resolved 20 October 2023
Resolution: Received, reviewed and accepted class report / proper documentation from [name withheld] stating the deficienciency was rectified.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 October 2023 Resolved
Manually operated call points shall be located near each exit. PSCO saw unmarked call point in lower ER level by escape hatch forward port. 74 SOLAS (2020) II-2/7.7, Code 16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2023
Resolved 20 October 2023
Resolution: Received, reviewed and accepted class report / proper documentation from [name withheld] stating the deficienciency was rectified.
05 - Radio Communications › N/A - No Subsystem › Operation of GMDSS equipment
Issued 13 October 2023 Resolved
All equipment to which this chapter applies shall be a type approved by the administration. PSCO witnessed temp wiring connection from NAVTEX to ECDIS. 74 SOLAS (2020) IV/14.1, Code 16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2023
Resolved 20 October 2023
Resolution: Received, reviewed and accepted class report / proper documentation from [name withheld] stating the deficienciency was rectified.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 October 2023 Resolved
The condition of the ship and its equipment shall be maintained to confirm with the present regulations. PSCO witnessed hole in sensor stuffing tube near CH #1 portside. 74 SOLAS (2020) I/11 A, Code 16
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 October 2023
Resolved 20 October 2023
Resolution: Received, reviewed and accepted class report / proper documentation from [name withheld] stating the deficienciency was rectified.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Certification, verification and control
Issued 13 October 2023 Resolved
The company should maintain procedures for ships conformity to relevant rules and regulations. Due to the objective evidence in above deficiencies, a safety management external audit must be carried out by the administration or R.O. within 90 days. 74 SOLAS (2020) IX/3.2, ISM Code 6.4,7,10.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 October 2023
Resolved 20 October 2023
Resolution: Received, reviewed and accepted class report / proper documentation from [name withheld] stating the deficienciency was rectified.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 17 May 2021 Resolved
07106 - The fucntion of the fire detection and fire systems shall be periodically tested to the satisfaction of the administration by means of equipment producing hot air or smoke. PSCO observed inoperable smoke detectors above generators. Heat detectors were unable to be tested due to insufficient equipment. 74SOLAS(04) II-2/7.3.2 17 ac ** Issued prior to departure and amended to 16 ac
Action required: 705 - Other - as specified
Due 30 August 2021
Resolved 7 June 2021
Resolution: Updated deficiency to coincide with classification society short term cargo ship safety equipment certificate.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 17 May 2021 Resolved
08107 - An alarm system shall be provided indicationg any fault requiring attention and shall be capable of sounding an audible alarm in the main machinery control room. PSCO observed no audible alarms on the control panel in the engine control room. 74SOLAS(20) II-1/51.1.1 17 ac ** Issued prior to departure and amended to 16 ac
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 June 2021
Resolution: Recieved classification society report attesting to repairs and proper operation.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.