← All vessels
SOMERS ISLES
Freight Ship · General Dry Cargo Ship class · Built 2010s · USCG Southeast District (CGD-SE) · Other hulls named SOMERS ISLES
SOMERS ISLES is a 2012 freight ship. The Coast Guard has recorded 20 inspections since 2015, most recently in August 2025, along with 12 deficiencies and 6 operational controls.
Records from 2015 to 2025. Most recent: inspection, 13 August 2025.
- Built
- 2012
- Last inspected
- 13 August 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 12 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9375147 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
PHOX
1262242
Flag
NETHERLANDS
—
Maury page id
psix-1262242
Inspections, by type
…with no type recorded2
Years with a record
9 calendar years (2015–2025)
The 20 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it3871 - Convention (Subpart B), Gross Ton
1333 - Convention (Subpart B), Net Ton
4800 - Dead Weight, Ton
1333 - Convention (Subpart B), Net Ton
4800 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 20
13 August 2025
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8207479
23 May 2025
Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8142398
21 May 2025
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 8137659
15 November 2023
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7824842
16 May 2023
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7688813
6 January 2023
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7617313
27 December 2022
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7612110
13 December 2022
Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7608356
28 November 2022
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7600542
12 November 2022
In-Service Inspection
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7593260
21 May 2022
PSC B
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7455129
19 November 2020
PSC A
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 7096707
13 October 2019
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6831895
6 July 2019
ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6734667
13 October 2018
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6558212
17 October 2017
Administrative Inspection · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6289538
6 October 2017
ISPS III Exam · NPV Safety Exam · Ballast Water Examination
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6281989
4 January 2017
Administrative Inspection
Administrative · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6066851
3 November 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6031589
24 October 2015
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5749547
Deficiency record · 12
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 21 May 2025
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met... means shall be provided to control the leaks of flammable liquids.
PSCO observed accumulation of oil around the main engine and propulsion shaft.
74 SOLAS (20) II-2/4.1.1
03 - Water/Weathertight Conditions › N/A - No Subsystem › Freeboard marks
Issued 21 May 2025
Resolved
The ring, lines and letters shall be painted in white or yellow on a dark background or in black on a light ground.
PSCO observed that the deck line on the starboard size was painted red with a red background.
ICLL 66, Reg. 8
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 21 May 2025
Resolved
Each emergency generating set arranged to be automatically started shall be equipped with starting devices approved by the Administration with a stored energy capability of at least three consecutive starts. A second source of energy shall be provided for an additional three starts withing 30 min unless manual starting can be demonstrated to be effective.
PSCO observed that the second means of start was ineffective, due to bad batteries. Crew replaced the old battery with a new battery.
74 SOLAS (04) II-1/44.2
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 October 2019
Resolved
Flammable liquid lockers shall be protected by appropriate fire-extinguishing arrangement approved by the administration. Portable gasoline tanks stored in a locker that does not meet requirements for a flammable liquid locker. 74 SOLAS(04)II-2/10.6.3.2 - 10c
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 13 October 2019
Resolved
A vessel entering into or getting underway on the navigable waters of the United States shall conduct the tests described in 33CFR164.25. Vessels arrival and departure tests did not fulfill requirements of 33CFR164.25. 33CFR164.25 - 10c
Lifesaving › Inflatable Liferafts › Painter
Issued 6 October 2017
Resolved
74SOLAS (04)III/13.4.2 The liferaft painter system shall provide a connection between the ship and life raft and shall be so arranged as to ensure when inflated is not dragged under by the ship. Painter on both liferafts were found to be connected to the ship and not the weak link, making them not float free.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 6 October 2017
Resolved
74SOLAS (14)II-1/40.1.3 Electrical installations shall be such that the safety of passengers and crew and ship from electrical hazards will be ensured. Purifier control panel was open due to overheating electrical components.
Electrical › Electrical Distribution System (service) › Non-conducting Deck Covering
Issued 6 October 2017
Resolved
74SOLAS (14)II-1/45.2 Main and emergency switch board shall be so arranged where necessary non conducting mats or gratings shall be provided. Non conductive mats were not provided throughout fore peak and machinery spaces.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 6 October 2017
Resolved
74SOLAS (14)III/7.1.2 Buoyant lifelines shall have a breaking strength of not less than 5 kn. Two forward lifebuoy lifelines were found to be deteriorated.
Lifesaving › Lifeboat Equipment › Food Ration
Issued 6 October 2017
Resolved
74SOLAS (14)III/34 Normal equipment of every lifeboat shall consist of food rations kept in airtight packaging and stowed in a watertight container. Two lifeboat food rations found not airtight.
Operations/Management › Port and Waterways Safety › Notice of Arrival, General
Issued 4 January 2017
Resolved
Vessel did not follow 12 hour update requirement. LOW was issued.
Electrical › Electric Generation Source (emergency) › Generator
Issued 3 November 2016
Resolved
Emergency generator's second means of starting is inop.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.