Records from 2016 to 2026. Most recent: inspection, 26 May 2026.
Inspection history · 24
26 May 2026
Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8438000
14 May 2025
Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 8137334
7 May 2024
COI Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7903619
20 November 2023
Drydock Exam · Internal Structural Exam
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7827689
14 June 2023
Deficiency Check · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7716379
26 April 2023
Damage Survey
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7675911
25 April 2023
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7748542
31 October 2022
Plan Review "T" Boat · Administrative Inspection
Administrative · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7586993
26 August 2022
Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7552821
23 May 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7467425
25 April 2022
Damage Survey · Examination of Repairs
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7440004
6 May 2021
DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7191113
26 July 2020
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 7017973
12 June 2020
DAPI Audit · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6974684
17 September 2019
Plan Review "T" Boat · Construction Oversight · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6824406
28 June 2019
Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6737196
28 June 2019
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6845454
26 March 2019
Administrative Inspection · Deficiency Check · DAPI Audit · COI Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6649373
14 August 2018
In-Service Inspection · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6511667
2 July 2018
Damage Survey · Administrative Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6465410
1 July 2018
Type not recorded
No type recorded · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6473374
27 November 2017
Examination of Repairs · Internal Structural Exam · Drydock Exam · Administrative Inspection · DAPI Audit · Annual Inspection · Deficiency Check
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6313513
11 May 2017
Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 6146657
11 April 2016
Administrative Inspection · Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Eastern Great Lakes · USCG Great Lakes District (CGD-GL) · Activity 5851559
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 May 2024
Resolved
Life rings were found deteriorated and unservicable. Replace both life rings.
Action required: 10 - Deficiency Rectified
Resolved 7 May 2024
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 7 May 2024
Resolved
Center support member was found wasted under cement filled ballast box.
Action required: 10 - Deficiency Rectified
Resolved 7 May 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 7 May 2024
Resolved
Cable run in pump room was unsupported and unsealed at engine room bulkhead. Brace or support cable run and seal bulkhead penetrations.
Action required: 10 - Deficiency Rectified
Resolved 7 May 2024
09 - Working and Living Conditions › 092 - Working Conditions › Ropes and wires
Issued 7 May 2024
Resolved
Wire rigging shackle was found unsecured. Tighten shackle pin and rewire.
Action required: 10 - Deficiency Rectified
Resolved 21 May 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 June 2023
Resolved
Install guards over belts and rotating machinery on the vessels newly installed main diesel engines.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2023
Resolved 6 July 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 June 2023
Resolved
Vessel was not supplied with aspirin in the on board first aid kit. Vessel Owner/Operator shall provide the first aid kit with aspirin which is not expired.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2023
Resolved 6 July 2023
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 June 2023
Resolved
CP3- Reinstall support brackets for the upper deck canopy to ensure the safety of the crew and passengers.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2023
Resolved 6 July 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 June 2023
Resolved
Vessels fixed fire extinguishing was found installed incorrectly. The relays for turning off the machinery in the event of activiation of the fire system were found disconnected. Repair or replace to ensure proper operation of the vessels fixed fire extinguishing system.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 June 2023
Resolved 14 June 2023
Resolution: Vessels fixed fire extinguishing system was diagnosed, repaired and tested while Marine Inspectors were still on board the vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 June 2023
Resolved
Vessels water pump was found unsupported and hanging by its wires. Ensure water pump is supported by its bracket to alleviate any electrical or water ingress concerns.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 14 June 2023
Resolved 14 June 2023
Resolution: Water pump was secured by the crew while marine inspectors were still on board the vessel.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 26 April 2023
Resolved
Make permanent repairs to hull and conduct sea trials on new engines to the satisfaction of the attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 June 2023
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 May 2022
Resolved
Permanently install forward battery charger at power connection and remove exposed receptacle outlet box
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2022
Resolved 6 September 2022
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 23 May 2022
Resolved
Reinstall cover for forward electrical junction box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 June 2022
Resolved 26 August 2022
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 23 May 2022
Resolved
Submit repair proposal for area of wood rot in forepeak space prior to next operating season.
Action required: 705 - Other - as specified
Due 1 May 2023
Resolved 6 September 2022
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 May 2022
Resolved
Provide aspirin in first aid kit.
Action required: 10 - Deficiency Rectified
Resolved 23 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 May 2021
Resolved
Float switches in holds #2 and #4 were inoperable. Repair or replace float switches on automatic bilge pumps to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 May 2021
Resolved 7 May 2021
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 28 June 2019
Resolved
AM1 - Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel had experienced a propulsion failure IWO their port engine control unit (Volvo Penta IPS) after control cable failed. Make satisfactory repairs to manufacturer specifications.
Action required: 701 - Prior to carriage of passengers/cargo
Due 28 June 2019
Resolved 28 June 2019
Resolution: Cable was replaced by contracted mechanic. Satisfactory operational test was conducted in presence of Marine Inspector.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 2 May 2019
Resolved
Two BII fire extinguishers were sent off to the fire
servicing facility and were not on board. Provide
servicing certificate and extinguishers on board vessel
prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2019
Resolved 7 May 2019
Resolution: Cleared to the satisfaction of attending marine inspector.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 2 May 2019
Resolved
Provide updated copies on board of both the U.S. Coast
Pilot and Coast Guard Light List within 14 days.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2019
Resolved 7 May 2019
Resolution: Cleared to the satisfaction of attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 May 2019
Resolved
The vessel only had 41 life jackets on aboard the vessel
at the time of the inspection. Provide all life jackets
in designated containers prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2019
Resolved 7 May 2019
Resolution: Cleared to the satisfaction of attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 May 2019
Resolved
All stencils for lifesaving equipment was not currently
in place. Provide all stencils for life jackets
containers prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2019
Resolved 7 May 2019
Resolution: Cleared to the satisfaction of attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 2 May 2019
Resolved
The number of passengers to be carried on the upper deck
is not adequately marked. Properly mark prior to
carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 May 2019
Resolved 7 May 2019
Resolution: Cleared to the satisfaction of attending marine inspector.
18 - Maritime Labour Convention (Not Applicable to PSC Exams conducted in the U.S.) › N/A - No Subsystem › Medical Equipment, medical chest, medical guide
Issued 2 May 2019
Resolved
The current first aid kit contains multiple expired
items. Provide all updated items as required. Vessel
has 14 days to clear.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2019
Resolved 7 May 2019
Resolution: Cleared to the satisfaction of attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 26 March 2019
Resolved
The vessel is required to carry 6 red hand flares and 6
orange smoke signals. The vessel currently has 8 red
hand flares on board. Provide four additional red hand
flares in accordance with the Great Lakes route. Vessel
is limited to Presque Isle Bay until rectified.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2019
Resolved 7 May 2019
Resolution: Cleared to the satisfaction of attending marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 August 2018
Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets. The interior of the vessel was recently painted and all life jacket boxes are not currently labeled. Required to be labeled prior to carrying passengers.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 August 2018
Resolved 14 August 2018
Resolution: Vessel O/O provided pictures showing all of the stenciled life jacket boxes.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 July 2018
Resolved
Prove proper operation of vessels propulsion to the satisfaction of the attending CGMI prior to commercial operation.
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 July 2018
Resolved 5 July 2018
Resolution: Attended vessel witnessing sat op of vessel propulsion systems.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 1 May 2018
Resolved
The crew of the vessel failed to retrieve OSCAR successfully. The procedure the vessel is currently using puts the deckhand over the side and at risk for going into the water. Provide training and come up with a procedure were an unconscious person can be retrieved using the current crew required by the COI. The drill needs to be performed with U.S. Coast Guard present before carrying passengers.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 May 2018
Resolved 7 May 2018
Resolution: Vessel crew successfully conducted underway drills in the presence of the marine inspector.
Stability › Watertight Integrity › General
Issued 1 May 2018
Resolved
Ensure all bulkheads in the voids are watertight. Areas that were caulked for the dry dock were found cracked.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2018
Resolved 7 May 2018
Resolution: All bulkheads properly sealed and verified by marine inspector.
Navigation › Piloting/Steering › US Coast Pilot
Issued 1 May 2018
Resolved
The vessel currently has an outdated Coast Pilot on board. Updated copy needs to be provided.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 May 2018
Resolved 1 May 2018
Resolution: A new version was downloaded and placed on board.
Operations/Management › Drills/Instruction › Fire
Issued 9 May 2016
Resolved
Revise emergency procedures-specific to vessel
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2016
Resolved 12 May 2016
Resolution: Examined revised emergency procedures-specific to vessel and conducted MOB and FIRE drills underway
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 9 May 2016
Resolved
Revise emergency procedures-specific to vessel
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 May 2016
Resolved 12 May 2016
Resolution: Examined revised emergency procedures-specific to vessel and conducted MOB and FIRE drills underway
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 9 May 2016
Resolved
Provide approved first aid kit
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 12 May 2016
Resolution: Provided approved first aid kit (receipt)
Engineering › Bilge Water Management System › Not Operational
Issued 9 May 2016
Resolved
Bilge pump float switch inop #2 void(bow thruster)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 12 May 2016
Resolution: Examined loose connection secured for bilge pump float switch in #2 void(bow thruster)
Communications › Radio Communications › VHF Radiotelephone
Issued 9 May 2016
Resolved
Add vessel name to radio placard
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 12 May 2016
Resolution: Examined vsl name to added to emergency radio placard
Documentation › Markings/Placards › Official Number (US)
Issued 9 May 2016
Resolved
Permanently affix official number to hull
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 12 May 2016
Resolution: Examined official number permanently affixed to hull
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 9 May 2016
Resolved
Replace wood fuel sounding stick
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 12 May 2016
Resolution: Examined replacement plastic sounding stick
Accommodation/Occupational Safety › Washroom/Toilet › Toilet
Issued 9 May 2016
Resolved
Clean washroom and ice cooler
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 12 May 2016
Resolution: Inspected clean washroom and ice cooler
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 9 May 2016
Resolved
Post EAP and SAP contact information
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 12 May 2016
Resolution: Examined EAP and SAP contact information posted
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 May 2016
Resolved
Secure battery terminals
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 12 May 2016
Resolution: Inspected all battery terminals secured
Electrical › Lighting (service) › Conductor
Issued 9 May 2016
Resolved
Loose/ disconnected wiring in aft overhead #3 void (fuel tank)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 May 2016
Resolved 12 May 2016
Resolution: Inspected secured loose/ disconnected wiring in aft overhead #3 void (fuel tank)