MAURY USCG vessel records
← All vessels

VIKING SKY

VIKING SKY is a 2017 passenger vessel (inspected). The Coast Guard has recorded 11 inspections since 2016, most recently in December 2025, along with 15 deficiencies and 2 operational controls.

Records from 2016 to 2025. Most recent: inspection, 19 December 2025.

Built
2017
Last inspected
19 December 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9650420
1264312
Flag
NORWAY
Maury page id
psix-1264312

Inspections, by type

…with no type recorded1
Years with a record 7 calendar years (2016–2025)
The 11 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Documentation record

Tonnage as PSIX records it47800 - Regulatory (Subpart C or D), Gross Ton
47842 - Convention (Subpart B), Gross Ton
3640 - Dead Weight, Ton
18858 - Convention (Subpart B), Net Ton
25774 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

One vessel history report for this hull — every record on this page in one dated, citable document — $300, on request.

Inspection history · 11

19 December 2025 PSC A · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 8283587
4 August 2025 Administrative Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8202072
17 June 2025 COC-CVE Quarterly · PSC B
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8160302
5 January 2025 PSC B · COC-CVE Annual
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8057424
19 December 2024 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8072554
30 November 2023 COC-CVE Initial · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7829522
5 April 2020 In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935492
27 December 2019 COC-CVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6876930
2 October 2017 Ballast Water Examination · ISPS II Exam · COC-CVE Initial
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6277861
12 December 2016 COC-CVE Initial Prep
Type not classified · Activities Europe · Activity 6056273
5 August 2016 Construction Oversight
Physical examination · Activities Europe · Activity 5963012

Deficiency record · 15

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 December 2025 Resolved
A fixed fire-extinguishing syste, required by this chapter shall comply with the provisions of the Fire Safety Systems Code.FSS 2.4.2.5 A gauge indicating the pressure in the system shall be provided at each section stop valve and at a central station. Gauges at section valves A47, A32, A33, and A31 reading inconsistent and inaccurate pressures. 74 SOLAS 20 II-2/10.4.1.1 Code 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2026
Resolved 6 January 2026
Resolution: Received statement of [name withheld] attesting to defecencies issues 19DEC2025 have been rectified.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 December 2025 Resolved
A fixed fire-extinguishing syste, required by this chapter shall comply with the provisions of the Fire Safety Systems Code.FSS Code 2.4.2.2 Each section of sprinklers shall be capable of being isolated by one stop valve only. At section valve A33 deck A FZ 3, the stop valve did not isolate the sprikler head. 74 SOLAS 20 II-2/10.4.1.1 Code 50ac
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 January 2026
Resolved 6 January 2026
Resolution: Received statement of [name withheld] attesting to defecencies issues 19DEC2025 have been rectified.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 19 December 2025 Resolved
A fixed fire-extinguishing syste, required by this chapter shall comply with the provisions of the Fire Safety Systems Code. FSS Code 2.5.2.4 A list or plan shall be displayed at each indicating unit showing the spaces covered and the location of the zone in respect of eachsection. Suitable instructions for testing and maintenance shall be available. Section valves did not have list or plan displayed. 74 SOLAS 20 II-2/4.1.1 Code 50ac
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 January 2026
Resolved 6 January 2026
Resolution: Received statement of [name withheld] attesting to defecencies issues 19DEC2025 have been rectified.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 17 June 2025 Resolved
Except for hatches between cargo, special category, store, and baggage spaces, and between such spaces and the weather decks, openings shall be provided with permanently attached means of closing which shall be at least as effective for resisting fires as the divisions in which they are fitted. PSCOs observed x02 fire doors in machinery space not latching properly and x02 fire doors had broken self-closing mechanisms. Cite: 74 SOLAS 20 II-2/9.4.1.1.1 Code: 17 c - cleared
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 June 2025
Resolution: Crew was able to recify door status in front of PSCOs. Cleared.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 17 June 2025 Resolved
The arrangements for the ready availability of water supply shall be in passenger ships of 1,000 gross tonnage and upwards such that at least one effective jet of water is immediately available from any hydrant in an interior location and so as to ensure the continuation of the output of water by the automatic starting of one required fire pump. When testing local application of water mist in engine purifier space, there was no ready availability of water. Cite: 74 SOLAS 20 II-2/10.2.1.2 Code: 17 c - cleared
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 June 2025
Resolution: Crew was able to identify the issue and retest the local water mist system properly in presence of PSCOs. Cleared deficiency.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 17 June 2025 Resolved
Fire protection systems ad fire-fighting systems and appliances shall be maintained ready for use. PSCOs observed x01 blocked water mist nozzle in aft purifier space. Cite: 74 SOLAS II-2/14.1.1 Code: 17 c - cleared
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 17 June 2025
Resolution: Crew fixed the obstructed bulb in front of PSCOs. Cleared deficiency.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 17 June 2025 Resolved
After any survey of the ship under regulations 7,8,9, or 10 has been completed, no change shall be made in the structural arrangement...PSCOs observed cross flooding hatch painted over. Could not confirm functionality of the paint. Cite: 74 SOLAS 20 I/11(b) Code: 16 abc
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2025
Resolved 4 August 2025
Resolution: Received class documentation attesting to rectification of open deficiency. See documents tab for further details.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 17 June 2025 Resolved
Every ship of 100 gross tonnage and above, and every ship which is certified to carry 15 or more persons, and fixed or floating platforms shall carry a garbage management plan which the crew shall follow. PSCOs observed improper stowage of garbage on FWD mooring deck as per their garbage management plan. Cite: MARPOL 2017 Annex V/10.2 Code: 16 abc
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 July 2025
Resolved 4 August 2025
Resolution: Received class documentation attesting to rectification of open deficiency. See documents tab for further details.
09 - Working and Living Conditions › 092 - Working Conditions › Obstruction/slipping, etc.
Issued 17 June 2025 Resolved
Machinery, boilers and other pressure vessels shall be so installed and protected as to reduce to a minimum any danger to persons on board, due regard being paid to moving parts, hot surfaces, and other hazards. PSCOs observed tripping and slipping hazards throughout engine room. Cite: 74 SOLAS 20 II-1/26.1 Code: 50 abc
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2025
Resolved 4 August 2025
Resolution: Received class documentation attesting to rectification of open deficiency. See documents tab for further details.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 17 June 2025 Resolved
The following functional requirements shall be met: escape routes shall be maintained in a safe condition, clear of obstacles. Means of escape in engine room were obstructed by stowage. Observed crew moving stowage that was blocking escape route path. Cite: 74 SOLAS 20 II-2/13.1.2 Code: 10c
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 17 June 2025
Resolution: Crew removed obstackes out of escape route as soon as it was pointed out. Rectified on the spot.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 17 June 2025 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: the ignitability of combustible materials shall be restricted. PSCOs observed improper stowage of combustible materials in Bosun Store and Carpenter Workshop. Cite: 74 SOLAS 20 II-2/4.1.3 Code: 10 c
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Resolved 17 June 2025
Resolution: Crew removed items stowed above sprinkler heads and in void spaces. Rectified on the spot.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 January 2025 Resolved
Alleyways, stairways and exits giving access to the muster and embarkation stations shall be lighted. Such lighting shall be capable of being supplied by the emergency source of electrical power. In addition routes to must stations shall be indicated with the muster station symbol, intended for that purpose. PSCO identified the following emergency light inoperable: Above port FWD life raft station and light in the vicinity of life boat #6. 74 SOLAS 20 III/11.5
Action required: 10 - Deficiency Rectified
Resolved 5 January 2025
Resolution: Vessel corrected during exam.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 January 2025 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairwell enclosures, except those for emergency escape trunks, shall be capable of remote release from the continuously manned central control station, either simultaneously or in groups, and shall be capable of release also individually from a position at both sides of the door. Release switches shall have an on off function to prevent automatic resetting of the system. PSCO observed fire door A.2.01 not release upon local activation. 74 SOLAS 20 II-2/9.4.1.1.5.3
Action required: 10 - Deficiency Rectified
Resolved 5 January 2025
Resolution: Vessel corrected during exam.
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 5 January 2025 Resolved
Fire doors in main vertical zone bulkheads, galley boundaries and stairway enclosures shall be self-closing and be capable of closing with an angle of inclination of up to 3.5 degrees opposing closure. PSCO observed fire door C.1.06 not freely close shut due to partial obstruction by exhaust gas scrubber piping. 74 SOLAS 20 II-2/9.4.1.1.5.1
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 February 2025
Resolved 31 January 2025
Resolution: Received work order completion report from vessel.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 5 January 2025 Resolved
The following functional requirements shall be met: Escape routes shall be maintained in a safe condition, clear of obstacles. PSCO observed pallet obstructing means of escape from the water treatment room and spare parts blocking means of escape from the engine store keeper space. 74 SOLAS 20 II-2/13.1.2
Action required: 10 - Deficiency Rectified
Resolved 5 January 2025
Resolution: Vessel corrected during exam.