Records from 2016 to 2025. Most recent: inspection, 4 August 2025.
Documentation record
Tonnage as PSIX records it7680 - Simplified, Gross Ton
7680 - Convention (Subpart B), Gross Ton
3846 - Convention (Subpart B), Net Ton
4824 - Simplified, Net Ton
11950 - Dead Weight, Ton
15367 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Inspection history · 12
4 August 2025
Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 8207487
20 May 2025
PSC B
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8139546
10 May 2022
PSC B
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 7444446
30 April 2022
Administrative Inspection
Administrative · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 7441087
8 November 2019
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6852489
26 April 2019
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6682887
28 January 2019
ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6615779
20 April 2017
ISPS II Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6129996
11 November 2016
Ballast Water Examination
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 6039260
4 April 2016
ISPS II Exam · PII Safety Exam
Physical examination · Marine Safety Unit Cleveland · USCG Great Lakes District (CGD-GL) · Activity 5834221
30 March 2016
Administrative Inspection · Enhanced Seaway Inspection (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5843775
30 March 2016
Administrative Inspection · ISPS II Exam · Enhanced Seaway Inspection (Massena only) · Joint Vessel Security Verification (Massena only)
Physical examination · Marine Safety Detachment Massena · USCG Great Lakes District (CGD-GL) · Activity 5847827
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 August 2025
Resolved
All vessels must submit a notice of arrival within the times required in paragraph (a)(4) of 33 CFR 160.212 (a). Vessel failed to submit an electronic notice of arrival prior to arriving at the port of Duluth on 04 AUG 2025.
33 CFR 160.212(a)(1)
10C
Action required: 10 - Deficiency Rectified
Due 4 August 2025
Resolved 4 August 2025
Resolution: Vessel agent submitted the required notice prior to vessel mooring at the facility.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 20 May 2025
Resolved
Every liferaft shall be stowed with its painter permanently attached to the ship.
The port liferaft painter was not connected to the ship.
Action required: 10 - Deficiency Rectified
Resolved 20 May 2025
Resolution: Corrected prior to completion of exam.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 20 May 2025
Resolved
Each liferaft or group of liferafts shall be stowed with a float-free arrangement complying with the requirements of paragraph 4.1.6 of the Code so that each floats free and, if inflatable, inflates automatically when the ship sinks.
The starboard liferaft is hooked up improperly to the hydrostatic release - on a permanent shackle and not through the weak link.
Action required: 10 - Deficiency Rectified
Resolved 20 May 2025
Resolution: Corrected prior to completion of exam.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 May 2025
Resolved
Maintenance, testing and inspections of life-saving appliances shall be carried out in a manner having due regard to ensuring reliability of such appliances.
Liferaft # 11763211 had two required tests indicated on the service certificate that were past their due date.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 May 2025
Resolution: Received corrected certificate indicating liferaft is in compliance.