NEW PRESTIGE is a 2013 freight ship. The Coast Guard has recorded 6 inspections since 2016, most recently in April 2025, along with 7 deficiencies and 1 operational control.

Records from 2016 to 2025. Most recent: inspection, 4 April 2025.

Built
2013
Last inspected
4 April 2025
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 4 April 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9598206
1264590
Flag
PANAMA
Maury page id
psix-1264590

Documentation record

Tonnage as PSIX records it44373 - Convention (Subpart B), Gross Ton
27546 - Convention (Subpart B), Net Ton
95789 - Displacement, Ton
82044 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 6

4 April 2025 PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8098078
17 August 2022 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7523942
12 September 2020 PSC B
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7048016
26 October 2018 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6564632
24 October 2016 ISPS II Exam · NPV Safety Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6019558
10 January 2016 Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5795514

Deficiency record · 7

14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 4 April 2025 Resolved
After any survey of the ship under paragraph 1 of this regulation has been completed, no change shall be made in the structure, equipment, systems, fittings, arrangements or material covered by the survey. PSCO observed after market valve on OWS installed that did not match ships drawings. Request clarification from certificate issuing authority on continued acceptance.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2025
Resolution: PSC NOLA received a class report from Lloyds Register satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 4 April 2025 Resolved
The machinery, boilers, and other pressure vessels associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed rerouted ventilation feeding SSGs. Request clarification from certificate issuing authority on continued acceptance.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2025
Resolution: PSC NOLA received a class report from Lloyds Register satisfying the requirement.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 4 April 2025 Resolved
The machinery, boilers, and other pressure vessels associated piping systems and fittings shall be of a design and construction adequate for the service for which they are intended. PSCO observed improperly installed thermal couplings on main engine cylinder #3 and #4.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 6 April 2025
Resolution: PSC NOLA received a class report from Lloyds Register satisfying the requirement.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 17 August 2022 Resolved
The purpose of this regulation is to suprress and swiftly extinguish a fire in the space of origin. Fire extinguishing appliances shall be readily available. Fire hysrant at 5WBT port side unable to be closed, resulting in low presure while testing emergency fire pump.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 August 2022
Resolved 17 August 2022
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 17 August 2022 Resolved
Before the ship leaves port and at all times during the boyage, all lifepsaving appliances shall be in working order and ready for immediate use. Rescue boat engine unable to engage astern.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 August 2022
Resolved 17 August 2022
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 26 October 2018 Resolved
04114 - Emergency source of power(Emergency Generator) - The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed a major coolant leak from the radiator of the emergency generator set. 74 SOLAS (14 Cons.) I/11 17c
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 October 2018
Resolution: Recieved video clearing deficiency
Navigation › Piloting/Steering › Gryo Compass Repeater
Issued 10 January 2016 Resolved
Received report attesting to the malfunction of the vessels gyrocmopass repeater.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 27 January 2016
Resolution: Recieved tech report attesting to repair and proper operation. LOD cleared.