MAURY USCG vessel records Sign in
← All vessels

ANDERS ELEVATOR

ANDERS ELEVATOR is a 1974 industrial vessel. The Coast Guard has recorded 33 inspections since 1990, most recently in July 2012, along with 40 deficiencies and 2 casualty investigations between 2013 and 2014.

Records from 1990 to 2014. Most recent: casualty investigation, 28 January 2014.

Built
1974
Last inspected
26 July 2012
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WAH9207
126575
Flag
UNITED STATES
367539420
Maury page id
psix-126575

Inspections, by type

Years with a record 20 calendar years (1990–2012)
The 33 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 14 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Miscellaneous Vessel class in Maury's sources begin in 1979.

Documentation record

Registered dimensions (L × B × D)51.0 ft × 24.0 ft × 4.4 ft
Registered tonnagegross 65 / net 56
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderELEVATING BOATS, INC · CAERNARVON, LA, UNITED STATES · built 1974
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portEMPIRE, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 June 2026 · expires 30 June 2027
Service, as the file records itIndustrial Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it56 - Regulatory (Subpart C or D), Net Ton
65 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG4720MMSI 367539420 · active · compulsorily equipped · granted 27 May 2022, expires 18 July 2032
WAH9207MMSI 366742930 · expired · compulsorily equipped · granted 15 January 1998, cancelled 19 February 2005 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 33

26 July 2012 In-Service Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4383540
9 April 2009 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3445666
27 May 2008 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3212061
5 March 2007 COI Inspection · Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2882055
22 May 2006 Annual Inspection · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2650626
11 March 2005 Annual Inspection · Hull Examination
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2307929
7 March 2005 Administrative Inspection
Administrative · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2305151
7 June 2004 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 2090942
22 August 2003 Annual Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1883645
18 May 2001 Damage Survey
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1461401
30 January 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1366141
2 March 2000 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1046877
2 December 1999 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1401106
27 June 1999 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 886338
20 May 1998 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 791577
11 May 1998 Re-Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1473375
24 April 1997 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1101148
16 April 1997 Hull Examination · COI Inspection · Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1439834
11 June 1996 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1367785
16 May 1996 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1367753
17 March 1995 COI Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1409250
16 March 1995 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1174981
23 February 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1159684
22 August 1994 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 874465
20 July 1994 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1380020
10 August 1993 Hull Examination · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1389686
22 October 1992 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1264978
30 July 1992 Inclining Experiment
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1266049
21 October 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 942840
21 October 1991 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1254049
22 August 1991 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 932338
18 December 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 900872
29 March 1990 Initial Certification · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 930290

Deficiency record · 40

Operations/Management › Equipment Service/Testing › EPIRB
Issued 27 May 2008 Resolved
Re-register EPIRB with NOAA - it expired in December 2007
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2008
Stability › Intact Stability (when using lifting gear) › General
Issued 27 May 2008 Resolved
Prove proper operation of deadmans switch to attending marine inspector. No operations can be conducted until this is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 3 June 2008
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 27 May 2008 Resolved
Prove proper operation of starboard engine to attending marine inspector.
Action required: 705 - Other - as specified
Resolved 3 June 2008
Fire Fighting › Remote Fuel Shutoff › General
Issued 27 May 2008 Resolved
Prove proper operation of emergency fuel shutoffs to attending marine inspector.
Action required: 705 - Other - as specified
Resolved 3 June 2008
Pollution Prevention/Response › Prevention Equipment › Drains/Scuppers (means of closure)
Issued 27 May 2008 Resolved
Show proper operation of valves on the bottom aft of each fuel tank to prevent leak, to the satisfaction of the marine inspector.
Action required: 705 - Other - as specified
Resolved 3 June 2008
Electrical › Electric Supply System (service) › Cable
Issued 11 March 2005 Resolved
Remove dead end wires in way of battery boxes and stbd engine.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 15 March 2005
Resolution: Dead end wires were removed.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 11 March 2005 Resolved
Repair conduit in way of distribution box and circuit box.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 15 March 2005
Resolution: Conduit in distribution box and circuit box repaired.
Lifesaving › Lifefloat › Retroreflective Material
Issued 11 March 2005 Resolved
Replace reflective tape on lifefloat that has been written on.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 15 March 2005
Resolution: New reflective tape installed on lifefloat.
Engineering › Diesel Engine (propulsion-direct drive) › Governor
Issued 11 March 2005 Resolved
Repair throttle bar on stdb engine.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 11 March 2005
Resolution: Replaced throttle bar.
Engineering › Fuel Oil Storage/Transfer System › Gauge
Issued 11 March 2005 Resolved
Replace gauge on hydaulic oil tank.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 15 March 2005
Resolution: Gauge on hydraulic oil tank replaced.
Stability › Water on Deck › General
Issued 11 March 2005 Resolved
Repair cracks in stbd bulwark in way of main generator as marked.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 15 March 2005
Resolution: Cracks in bulwark repaired.
Deck/Cargo › Cargo Stowage › General
Issued 11 March 2005 Resolved
Prove paint locker is airtight.
Condition: Unknown
Action required: 705 - Other - as specified
Due 10 April 2005
Resolved 15 March 2005
Resolution: Paint locker made airtight.
Communications › Radio Communications › EPIRB
Issued 11 March 2005 Resolved
EPIRB not registered.
Condition: Unknown
Due 15 March 2005
Resolved 15 March 2005
Resolution: EPIRB registered.
Construction/Loadline
Issued 18 May 2001 Resolved
EFFECT TEMP REPAIRS TO 3' CRACK IN PORT BOW W/ DOUBLER WELDED FROM OUTSIDE,W/ FIRE WATCH, ALL HAZMAT REMOVED FROM BILGES, AND HOSE TESTING AFTER. EFFECT PERMANENT REPAIRS TO SATISFACTION OF ATTENDING MARINE INSPECTOR.
Condition: Unknown
Due 28 May 2001
Resolved 4 June 2001
Construction/Loadline
Issued 2 December 1999 Resolved
SUBMIT COPIES OF WELD PROCEDURE FOR HIGH STRENGTH STEEL AND INVOICE/WORK ORDER FOR LEG REPAIRS ACCOMPLISHED AT EBI.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Construction/Loadline
Issued 2 December 1999 Resolved
REWELD BROKEN FRAME NEAR RUDDERS IN ENGINE ROOM.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Electrical
Issued 2 December 1999 Resolved
PROVIDE BATTERY-POWERED SUPPLY TO VHF RADIO.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Lifesaving
Issued 2 December 1999 Resolved
PROVIDE RESCUE BOAT ARRANGEMENT IAW CCGD8 LETTERS 16711 DTD 25AUG99 AND 16613 DTD 12NOV98. VESSEL IS TO SUBMIT BROCHURE AND VIDEO OF EBI WORK/RESCUE BOAT RECENTLY PURCHASED.
Condition: Unknown
Due 2 December 1999
Resolved 2 December 1999
Construction/Loadline
Issued 11 May 1998 Resolved
CROP AND RENEW TO GOOD METAL WASTED AREAS IN THE DECK HOUSE AND PILOT HOUSE(ALL SIDES), REMOVE ALL SOFT REPAIRS AND TOP OF PILOT HOUSE.
Condition: Unknown
Due 11 May 1998
Resolved 11 May 1998
Construction/Loadline
Issued 11 May 1998 Resolved
CROP AND RENEW 2 LONGITUDINALS PORT SIDE AFT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 May 1998
Resolved 11 May 1998
Engineering
Issued 11 May 1998 Resolved
DOUBLE NUT OR LOCKNUT ALL ENGINE CONTROL LINKAGES.
Condition: Unknown
Due 1 June 1998
Resolved 13 May 1998
Construction/Loadline
Issued 11 May 1998 Resolved
RENEW STEERING PULLEY BRACKET ON PORT SIDE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 May 1998
Resolved 11 May 1998
Construction/Loadline
Issued 11 May 1998 Resolved
CROP AND RENEW UNDERDECK LONG #1 PORT SIDE AFT UNDER CLEAT._x001C_
Condition: Unknown
Due 1 June 1998
Resolved 13 May 1998
Construction/Loadline
Issued 11 May 1998 Resolved
GOUGE AND REWELD INSERT INSTALLED BEHIND STEERING PULLEY._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 11 May 1998
Resolved 11 May 1998
Deck/Cargo
Issued 11 May 1998 Resolved
RENEW HYDRAULIC FITTINGS ON DECK HYDRAULIC PUMP.
Condition: Unknown
Due 1 June 1998
Resolved 13 May 1998
Accommodation/Occupational Safety
Issued 16 April 1997 Resolved
SECURE WASHER AND DRYER
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Lifesaving
Issued 16 April 1997 Resolved
REPLACE/REPAIR LIFEFLOAT AND STROBE LANYARD
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Accommodation/Occupational Safety
Issued 16 April 1997 Resolved
INSTALL PROPER MATTRESSES IN ACCOMMODATION SPACE AND LADDERS TO TOP BUNKS
Condition: Unknown
Due 16 April 1997
Resolved 16 April 1997
Construction/Loadline
Issued 16 May 1996 Resolved
Crop and renew wasted deck plating in way of port leg, outboard side.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Construction/Loadline
Issued 16 May 1996 Resolved
Reweld vertical stiffener on transom, port outboard corner.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Deck/Cargo
Issued 16 May 1996 Resolved
Relabel/replace angle indicator on deck crane.
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Engineering
Issued 16 May 1996 Resolved
Repair/replace engine RPM gauges in pilot house
Condition: Unknown
Due 16 May 1996
Resolved 16 May 1996
Deck/Cargo
Issued 10 August 1993 Resolved
REPLACE SPRING AND AND PROVE PROPER OPERATION OF DEADMAN DEVICE IN THE PRESENCE OF CG INSPECTOR.
Condition: Unknown
Due 12 September 1993
Resolved 17 August 1993
Electrical
Issued 10 August 1993 Resolved
REPLACE SEWAGE PUMP ELECTRICAL WIRE.
Condition: Unknown
Due 12 September 1993
Resolved 17 August 1993
Accommodation/Occupational Safety
Issued 10 August 1993 Resolved
REPLACE DAMAGED HOLDING TANK FOR MSD.
Condition: Unknown
Due 12 September 1993
Resolved 17 August 1993
Engineering
Issued 10 August 1993 Resolved
REPAIR AND PROVE PROPER OPERATION OF STARBOARD REMOTE FUEL SHUTDOWN.
Condition: Unknown
Due 12 September 1993
Resolved 17 August 1993
Engineering
Issued 29 March 1990 Resolved
REPLACE PORT AND STBD MAIN ENGINE FUEL OIL RETURN LINES WITH USCG-APPROVED FIRE-RESISTANT HOSE.
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Documentation
Issued 29 March 1990 Resolved
SUBMIT FOR REVIEW AND APPROVAL BY COMMANDANT (G-MSC) THE FOLLOWING PLANS: GENERAL ARRANGEMENTS, INBOARD AND OUTBOARD PROFILES, STABILITY DATA, LEG STRUCTURES, JACKING TOWER STRUCTURES, AND HYDRAULIC JACKING SYSTEMS.
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Electrical
Issued 29 March 1990 Resolved
LABEL ALL BREAKERS IN GALLEY BREAKER BOX, AND LABEL EMERGENCY RANGE DISCONNECT.
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990
Documentation
Issued 29 March 1990 Resolved
SUBMIT FOR REVIEW AND APPROVAL BY COMMANDANT (G-MSC) AN OPERATING MANUAL. THIS MANUAL SHALL INCLUDE LOCATION AND REPAIR PROCEDURES FOR ALL HIGH-TENSILE STEEL USED IN CONSTRUCTION.
Condition: Unknown
Due 29 March 1990
Resolved 29 March 1990

Casualty record · 2

5 November 2013Routine · role: Involved in a Marine Casualty · activity 4747587
28 January 2014Routine · role: Involved in a Marine Casualty · 1 injured · activity 4793485
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record