ATHINOULA is a 2012 freight ship. The Coast Guard has recorded 8 inspections since 2018, most recently in January 2025, along with 5 deficiencies — 1 with no resolution recorded — and 1 operational control.
Records from 2018 to 2025. Most recent: inspection, 27 January 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it43022 - Convention (Subpart B), Gross Ton 27239 - Convention (Subpart B), Net Ton 82177 - Dead Weight, Metric Ton 94350 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 8
27 January 2025PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8064101
17 September 2021Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7314769
3 September 2021Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7303503
1 September 2021Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7311410
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 27 January 2025Resolved
MEANS SHALL BE PROVIDED TO CONTROL LEAKS OF FLAMMABLE LIQUIDS. PSCO OBSERVED SIGNIFICANT FUEL LEAK FROM THE BOILER FUEL OIL BURNING PUMP. PROVIDE REPORT FROM THE CERTIFICATE ISSUING AUTHORITY ATTESTING TO THE INTEGRITY OF THE SYSTEM. 74 SOLAS (CON) II-2/4.1.1, PRIOR TO MOVEMENT, 60ac
Action required: 60 - Rectify deficiencies prior to movement
Resolved 28 January 2025
Resolution: PSC NOLA received a class report from Nippon Kaiji Kyokai satisfying the requirement.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 27 January 2025Resolved
THE MACHINERY, BOILERS, AND OTHER PRESSURE VESSELS, ASSOCIATED PIPING SYSTEMS AND FITTINGS SHALL BE OF A DESIGN AND CONSTRUCTION ADEQUATE FOR THE SERVICE FOR WHICH THEY ARE INTENDED AND SHALL BE PROTECTED AS TO REDUCE TO A MINIMUM ANY DANGER TO PERSONS ON BOARD, DUE REGARD BEING PAID TO MOVING PARTS, HOT SURFACES AND OTHER HAZARDS. THE DESIGN SHALL HAVE REGARD TO MATERIALS USED IN CONSTRUCTION, THE PURPOSE FOR WHICH THE EQUIPMENT IS INTENDED, THE WORKING CONDITIONS TO WHICH IT WILL BE SUBJECTED AND THE ENVIRONMENTAL CONDITIONS ON BOARD. PSC OBSERVED MAKESHIFT COVER FOR SPINNING MACHINERY ON BOILER FUEL OIL BURNING PUMP. 74 SOLAS (CON) II-1/26.1, PRIOR TO DEPARTURE, 17ac
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Resolved 28 January 2025
Resolution: PSC NOLA received a class report from Nippon Kaiji Kyokai satisfying the requirement.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 27 January 2025No resolution recorded
THE COMPANY SHOULD ESTABLISH PROCEDURES TO ENSURE THAT THE SHIP IS MAINTAINED IN CONFORMITY WITH THE PROVISIONS OF THE RELEVANT RULES AND REGULATIONS AND WITH ANY ADDITIONAL REQUIREMENTS WHICH MAY BE ESTABLISHED BY THE COMPANY. AN INTERNAL AUDIT REPORT SATISFACTORY TO THE OCMI MUST BE CONDUCTED WITHIN 90 DAYS AND MUST BE SUBMITTED PRIOR TO CLEARANCE OF THIS DEFICIENCY. 74 SOLAS (AM) IX/5, ISM CODE 10, WITHIN 90 DAYS, ac
Action required: 705 - Other - as specified
Due 27 April 2025 — due date passed with no resolution recorded
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 3 September 2021Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. Due to heavy weather, the vessel was pushed aground in Lower Mississippi river. Certification issuing authority to attest to the proper operation of steering gear, propulsion machinery and associated equipment, and integrity of the hull in affected area and hull penetration on port side. hull damage, port side fwd 2 ft horizontal crack
Code: 02106 74 SOLAS (20) I/II (a) 60 (a)(c)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 September 2021
Resolution: Received class report, repairs inspected satisfactory, inlcuding affirmative insert weld 100% UT test. Ship is fit to reatin her class.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 8 May 2018Resolved
9900 - other - Vessel used air as testing medium during annual test of transfer pipe system. Flag state survey notated on report as an observation that it was not conducted IAW 33 CFR on 29APR18. Ship's crew took on bunkers on 6JAY18 without conducting a hydrostatic test of the bunker lines.
-33 CFR 156-170(c)(4)
-c
Action required: 703 - Prior to bunkering operations
Due 9 May 2018
Resolved 30 May 2018
Resolution: Received, reviewed and accepted documentation from vessel and class stating the test had been completed hydrostatically at 1.5 MAWP
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.