Records from 2016 to 2026. Most recent: inspection, 25 February 2026.
Inspection history · 18
25 February 2026
Deficiency Check · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8320910
5 November 2025
Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8264121
6 February 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 8072494
1 February 2024
Deficiency Check · COI Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7853968
25 October 2023
Deficiency Check · Internal Structural Exam · Plan Review "T" Boat · Examination of Repairs · Drydock Exam · Construction Oversight
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7814032
27 February 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7633787
27 April 2022
Deficiency Check · Examination of Repairs · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7439027
8 April 2022
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7439309
18 January 2022
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7381713
1 November 2021
Internal Structural Exam · Examination of Repairs · Deficiency Check · Drydock Exam · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7343298
15 April 2021
Annual Inspection · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 7175164
19 February 2020
Internal Structural Exam · Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6911867
21 October 2019
Internal Structural Exam · Administrative Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6839896
8 February 2019
COI Inspection · DAPI Audit · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6622403
16 October 2017
Damage Survey
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6290494
16 October 2017
Deficiency Check · DAPI Audit · Administrative Inspection · Internal Structural Exam · Hull Examination · Annual Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6514268
4 October 2017
Damage Survey
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6293391
28 April 2016
Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 5865518
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 February 2026
Resolved
Ring buoy needs new retro and vessel name put on it.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 March 2026
05 - Radio Communications › N/A - No Subsystem › Operation/maintenance
Issued 25 February 2026
Resolved
FCC staion auth. and FCC safety cert have expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 March 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 February 2026
Resolved
Engine room high water alarm only has audible alarm no visual.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 6 March 2026
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 6 February 2025
Resolved
Vessel is missing both updated copies of FFC safety Cert. and FCC station license.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 March 2025
Resolved 11 February 2025
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 February 2025
Resolved
Renew dilapidated retro tape on life ring.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 11 February 2025
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 February 2024
Resolved
EPIRB was not working and registration had expired last yr. Must make repairs or replace and register EPRIB and test to the satisfaction of attending CG Marine Inspector. Vessel is restricted to 1 mile from shore until cleared.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 1 February 2024
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 1 February 2024
Resolved
First aid kit did not have enough aspirin. Must replace missing aspirin to meet the 100 count requirement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 1 February 2024
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 February 2024
Resolved
Missing monthly EPIRB test logs. Must show proof of monthly EPRIB test.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 1 February 2024
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 1 February 2024
Resolved
Logs for MOB and fire drills are not being logged properly. Must show proof and log drills properly.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 1 February 2024
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 1 February 2024
Resolved
EPIRB hydrostatic release had expired last yr. Must replace hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 1 March 2024
Resolved 1 February 2024
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 27 February 2023
Resolved
Vessel unable to get underway and conduct drills due to transmission issue. Vessel must conduct MOB and fire drills sometime in the next 30 days.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 March 2023
Resolved 7 April 2023
Resolution: Replace oil cooler on port MDE. Underway to conduct drills. Drill SAT
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 1 November 2021
Resolved
Vessel failed to have its 2 year drydock inspection. Must conduct drydock inspection prior to carrying passengers.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 November 2021
Resolution: Drydock inspection completed.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 15 April 2021
Resolved
Both main diesel engines are missing the guards on the front of the engine that goes around the pulleys. Must install missing guards to protect personel from rotating machinery.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2021
Resolved 17 June 2021
Resolution: Sent pictures of BMDE guards installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 April 2021
Resolved
Both ventilation covers for main diesel engines would not latch closed, latches were broken on both. Must repair broken latches so covers will stay closed in case of fire.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2021
Resolved 15 April 2021
Resolution: Installed new latches on both vent covers.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 April 2021
Resolved
No paper copy of NAV chart and the GPS is not updated with latest software. Must either have updated approved paper NAV Chart or update GPS with lastest software.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 May 2021
Resolved 15 April 2021
Resolution: Updated Garmin GPS with latest software version.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 February 2020
Resolved
Life ring is wasted. Renew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 March 2020
Resolution: Life ring was purchased and renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 19 February 2020
Resolved
Life floats need new reflective material. Repair. Name and capacity on both sides.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2020
Resolution: Life float reflective was renewed, and name and capacity was stenciled on both sides of life raft.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 February 2020
Resolved
3 adult PFD’s are wasted. Renew. Total persons reduced to no more than 48.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 April 2020
Resolution: 03 adult PFD’s were purchased and properly put into service.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 February 2020
Resolved
Add abandon ship to drills.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2020
Resolution: Abandon ship drills were added to ships drill log.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 19 February 2020
Resolved
Track and log EPIRB testing every month.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2020
Resolution: Abandon ship drills were added to ships drill log.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 19 February 2020
Resolved
First aid kit is missing contents, inventory, and instruction sheets. Provide.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2020
Resolution: All missing content and instruction sheep has been provided for first aid kit.
04 - Emergency Systems › N/A - No Subsystem › Means of communication between safety centre and other control stations
Issued 19 February 2020
Resolved
Post emergency broadcast placard near VHF radio.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2020
Resolution: Renewed Emergency broadcast placard was mounted near VHF radio.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 19 February 2020
Resolved
Renew overhead insulation in engine room on hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 11 March 2020
Resolution: Renew overhead insulation in engine room on hatch. 177.300
Overhead insulation in engine room hatch was renewed, and verified.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 February 2019
Resolved
Missing 1 child size PFD/ Child count is reduced to not more than 5.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 February 2019
Resolution: Replaced
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 February 2019
Resolved
Provide vessel documentation and records.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 February 2019
Resolution: Provided
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 8 February 2019
Resolved
Renew/Repair cable to fuel shut-off.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2019
Resolution: Completed
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 8 February 2019
Resolved
Privide 1 2.5 gal Fire Bucket.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 February 2019
Resolution: Provided
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 8 February 2019
Resolved
Provide annual inspection on all fire equipment.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2019
Resolution: New logs have been created, and placed into use.
11 - Life Saving Appliances › N/A - No Subsystem › Means of recovery of life saving appliances
Issued 8 February 2019
Resolved
Life float painters must be re-installed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 February 2019
Resolution: Re-installed
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 8 February 2019
Resolved
Life floats require new reflective tape and paint.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2019
Resolution: Floats were repainted and remarked.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 8 February 2019
Resolved
Auto bilge visual alarm in laz is extinguished. Repair/Renew
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 February 2019
Resolution: New bilge alarms were installed.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 8 February 2019
Resolved
Vessel is missing all navigation publications. Provide up to date pubs.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 February 2019
Resolution: New publications were provided.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 10 November 2017
Resolved
Visual bilge alarm in the fwd compartment is extinguished. Repair.
Action required: 10 - Deficiency Rectified
Due 17 November 2017
Resolved 17 November 2017
Resolution: Bilge alarm visual indicator light was renewed, and tested, All sat.
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 November 2017
Resolved
When the fire system was tested, the override would not allow the engine to be restarted. Repair the engine override.
Action required: 10 - Deficiency Rectified
Due 17 November 2017
Resolved 17 November 2017
Resolution: New override switch was installed and tested, Sat.
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 10 November 2017
Resolved
Vessel is required to have a written waste management plan. Provide plan and post.
Action required: 10 - Deficiency Rectified
Due 24 November 2017
Resolved 24 November 2017
Resolution: Waste plan was provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 November 2017
Resolved
Emergency instructions list must be posted.
Action required: 10 - Deficiency Rectified
Due 24 November 2017
Resolved 24 November 2017
Resolution: Emergency onstructions were posted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 November 2017
Resolved
The vessel is missing the FCC safety certificate. Provide new Certificate.
Action required: 10 - Deficiency Rectified
Due 24 November 2017
Resolved 24 November 2017
Resolution: FCC safety certificate was provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 November 2017
Resolved
The vessel is required to have an emergency boardcast placard posted by the VHF radio. There is no placard posted.
Action required: 10 - Deficiency Rectified
Due 24 November 2017
Resolved 24 November 2017
Resolution: Radio boradcast placard was posted.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 November 2017
Resolved
Vessel is missing Coast Pilot, light list, and tide table. Provide new publications.
Action required: 10 - Deficiency Rectified
Due 24 November 2017
Resolved 24 November 2017
Resolution: New navigation publications were provided.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 10 November 2017
Resolved
First aid kit is incomplete. Provide new contents per CFR.
Action required: 10 - Deficiency Rectified
Due 24 November 2017
Resolved 24 November 2017
Resolution: A new first aid kit was provided.