TIGER NORTH is a 2013 freight ship. The Coast Guard has recorded 8 inspections since 2017, most recently in June 2024, along with 8 deficiencies and 3 operational controls.
Records from 2017 to 2024. Most recent: inspection, 26 June 2024.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it42114 - Convention (Subpart B), Gross Ton 25821 - Convention (Subpart B), Net Ton 76249 - Dead Weight, Metric Ton 89800 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 8
26 June 2024PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7937794
16 January 2023Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7621870
18 May 2022PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7441350
16 December 2019ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6868498
28 April 2018Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6401248
15 February 2018Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6355953
27 October 2017ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6292121
21 October 2017Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6292315
Hydraulic power steering gear shall be provided with the following: a fixed storage tank having sufficient capacity to recharge at least one power actuating system. PSCO observed the hydraulic oil storage tank at 1/8 full.
74 SOLAS (20) II-1/29.12
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2022
Resolved 20 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 May 2022Resolved
After a survey of the ship, no change shall be made in the machinery without the sanction of the administration. PSCO observed abnormal operation of the #2 A/E. C/E stated the motor was adjusted to operate at different parameters to avoid a recurring alarm.
74 SOLAS (20) I/11(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2022
Resolved 20 May 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2022Resolved
Paint lockers shall be protected by: a water spraying or sprinkler system. PSCO observed fixed sprinkler system leaking in paint stores.
74 SOLAS (20) II-2/10.6
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2022
Resolved 20 May 2022
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 May 2022Resolved
The following functional requirements shall be met: ignition sources shall be restricted. PSCO observed decaying refractory brick inside of the incinerator.
74 SOLAS (20) II-2/4.1.4
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2022
Resolved 20 May 2022
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 May 2022Resolved
An alarm system shall be provided indicating any fault requiring attention and shall be capable of sounding an audible alarm in the main machinery control room or at the propulsion machinery control position, and indicate visually each separate alarm function at a suitable position. PSCO observed broken STBD steering gear bilge alarm.
74 SOLAS (20) II-1/51.1.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2022
Resolved 20 May 2022
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed clogged filter alarm sounding when operating steering gear pump #1.
74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2022
Resolved 20 May 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2022Resolved
Maintenance, testing, and inspections shall be carried out in a manner having due regard to ensuring the reliability of firefighting systems and appliances. PSCO observed 06 firefighting hoses excessively leaking. PSCO observed 02 fire extinguishers with excessive corrosion in the oxygen and acetylene storage rooms.
74 SOLAS (20) II-2/14.2.2.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2022
Resolved 20 May 2022
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 18 May 2022Resolved
The company and the ship shall comply with the requirements of the International Safety Management code; the company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. Due to the lack of maintenance throughout the ship, the internal ISM audit is required within three months.
74 SOLAS (20) IX/3.1
ISM Code Reg 10.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2022
Resolved 17 January 2023
Resolution: PSC NOLA received proper documentation from issuing entity satisfying the requirement
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.