TIGER NORTH

TIGER NORTH is a 2013 freight ship. The Coast Guard has recorded 8 inspections since 2017, most recently in June 2024, along with 8 deficiencies and 3 operational controls.

Records from 2017 to 2024. Most recent: inspection, 26 June 2024.

Built
2013
Last inspected
26 June 2024
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

Identity

9619878
1267224
Flag
HONG KONG
Maury page id
psix-1267224

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspections, by type

…with no type recorded3
Years with a record 6 calendar years (2017–2024)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. The counts in the strip above are the same counts; this table splits the inspections by the kind of activity recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Documentation record

Tonnage as PSIX records it42114 - Convention (Subpart B), Gross Ton
25821 - Convention (Subpart B), Net Ton
76249 - Dead Weight, Metric Ton
89800 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

What it gives that this page does not: the whole record in one dated, citable document — every line with its Coast Guard activity id, the retrieval date on the cover, built to print to PDF with its page breaks — that a surveyor can attach and a lender can file. The same facts as this page, complete and in one file.

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

A request, not a checkout: leave an email and Maury replies once, with the dated document for this hull and a Stripe invoice for $299. Nothing is charged before the document is in your hands.

Inspection history · 8

26 June 2024 PSC B
Physical examination · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 7937794
16 January 2023 Deficiency Check · Administrative Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7621870
18 May 2022 PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7441350
16 December 2019 ISPS II Exam
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6868498
28 April 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6401248
15 February 2018 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6355953
27 October 2017 ISPS II Exam · PII Safety Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6292121
21 October 2017 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6292315

Deficiency record · 8

02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 18 May 2022 Resolved
Hydraulic power steering gear shall be provided with the following: a fixed storage tank having sufficient capacity to recharge at least one power actuating system. PSCO observed the hydraulic oil storage tank at 1/8 full. 74 SOLAS (20) II-1/29.12
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2022
Resolved 20 May 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 18 May 2022 Resolved
After a survey of the ship, no change shall be made in the machinery without the sanction of the administration. PSCO observed abnormal operation of the #2 A/E. C/E stated the motor was adjusted to operate at different parameters to avoid a recurring alarm. 74 SOLAS (20) I/11(b)
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 May 2022
Resolved 20 May 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2022 Resolved
Paint lockers shall be protected by: a water spraying or sprinkler system. PSCO observed fixed sprinkler system leaking in paint stores. 74 SOLAS (20) II-2/10.6
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2022
Resolved 20 May 2022
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 18 May 2022 Resolved
The following functional requirements shall be met: ignition sources shall be restricted. PSCO observed decaying refractory brick inside of the incinerator. 74 SOLAS (20) II-2/4.1.4
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2022
Resolved 20 May 2022
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 18 May 2022 Resolved
An alarm system shall be provided indicating any fault requiring attention and shall be capable of sounding an audible alarm in the main machinery control room or at the propulsion machinery control position, and indicate visually each separate alarm function at a suitable position. PSCO observed broken STBD steering gear bilge alarm. 74 SOLAS (20) II-1/51.1.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2022
Resolved 20 May 2022
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 18 May 2022 Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. PSCO observed clogged filter alarm sounding when operating steering gear pump #1. 74 SOLAS (20) I/11(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2022
Resolved 20 May 2022
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2022 Resolved
Maintenance, testing, and inspections shall be carried out in a manner having due regard to ensuring the reliability of firefighting systems and appliances. PSCO observed 06 firefighting hoses excessively leaking. PSCO observed 02 fire extinguishers with excessive corrosion in the oxygen and acetylene storage rooms. 74 SOLAS (20) II-2/14.2.2.1
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 May 2022
Resolved 20 May 2022
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 18 May 2022 Resolved
The company and the ship shall comply with the requirements of the International Safety Management code; the company should establish procedures to ensure that the ship is maintained in conformity with the provisions of the relevant rules and regulations. Due to the lack of maintenance throughout the ship, the internal ISM audit is required within three months. 74 SOLAS (20) IX/3.1 ISM Code Reg 10.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 August 2022
Resolved 17 January 2023
Resolution: PSC NOLA received proper documentation from issuing entity satisfying the requirement