MAURY USCG vessel records
← All vessels

NACC ANTIGUA

NACC ANTIGUA is a 2012 freight ship. The Coast Guard has recorded 10 inspections since 2016, most recently in September 2023, along with 5 deficiencies and 1 operational control.

Records from 2016 to 2023. Most recent: inspection, 22 September 2023.

Built
2012
Last inspected
22 September 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 22 September 2023
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 5 calendar years (2016–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9512587
1267483
Flag
PANAMA
Maury page id
psix-1267483

Documentation record

Tonnage as PSIX records it11251 - Convention (Subpart B), Gross Ton
4372 - Convention (Subpart B), Net Ton
17158 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 10

22 September 2023 PSC B
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7795375
21 September 2023 Administrative Inspection
Administrative · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7796245
27 October 2019 Deficiency Check · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6839862
19 December 2018 Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6601370
13 October 2018 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6560803
21 September 2018 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6543276
10 August 2017 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6236037
5 June 2017 Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6166196
14 April 2017 PII Safety Exam · ISPS II Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6124444
7 June 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5900086

Deficiency record · 5

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 September 2023 Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: Means shall be provided to control leaks of flammable liquids. Fuel oil booster pump found with active leak at o-ring assembly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2023
Resolved 22 September 2023
Resolution: USCG verified repair, test of pump witnessed. All found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 October 2019 Resolved
Accommodation and service spaces and control stations of cargo ships shall be protected by a fixed fire detection and fire alarm system and/or an automatic sprinkler, fire detection and fire alarm system as follows depending on a protection method adopted in accordance with regulation. PSCO discover 07 non-operational smoke detectors in vessel cargo tunnel areas. Fire detection system must be fully functional prior to departure. 74 SOLAS (2014) II-2/7.5.5 17 a,c
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 28 October 2019
Resolved 28 October 2019
Resolution: Received Class Report attesting to satisfactory repairs.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 21 September 2018 Resolved
1730- Oily water separating equipment - 10c System shall be provided w/arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15ppm. PSCO observed two of the three air hoses for the three way valve were ruptured, rendering it inoperable. MARPOL I/14.7
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 21 September 2018
Resolved 21 September 2018
Resolution: Hoses were replaced and the valve was tested satisfactory
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 20 April 2017 Resolved
0750: Means shall be provided to control leaks of flammable liquids. Sight glass for emergency generator F/O tank is leaking. 74SOLAS(04)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 21 April 2017
Resolution: Received class report attesting to the repairs.
Engineering › Fuel Oil Service System › Piping
Issued 20 April 2017 Resolved
0750. Means shall be provided to control leaks of flammable liquids. Thermal oil pipe for heating heavy F/O tanks is leaking. 74SOLAS(04)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 5 June 2017
Resolution: Received class report attesting to the repairs (attached).

Ownership record