← All vessels
NACC ANTIGUA
NACC ANTIGUA is a 2012 freight ship. The Coast Guard has recorded 10 inspections since 2016, most recently in September 2023, along with 5 deficiencies and 1 operational control.
Records from 2016 to 2023. Most recent: inspection, 22 September 2023.
- Built
- 2012
- Last inspected
- 22 September 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 5 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9512587 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
3FXR
1267483
Flag
PANAMA
—
Maury page id
psix-1267483
Inspections, by type
…with no type recorded1
Years with a record
5 calendar years (2016–2023)
The 10 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it11251 - Convention (Subpart B), Gross Ton
4372 - Convention (Subpart B), Net Ton
17158 - Dead Weight, Ton
4372 - Convention (Subpart B), Net Ton
17158 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 10
22 September 2023
PSC B
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7795375
21 September 2023
Administrative Inspection
Administrative · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7796245
27 October 2019
Deficiency Check · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6839862
19 December 2018
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6601370
13 October 2018
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6560803
21 September 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6543276
10 August 2017
Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6236037
5 June 2017
Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6166196
14 April 2017
PII Safety Exam · ISPS II Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6124444
7 June 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5900086
Deficiency record · 5
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 September 2023
Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: Means shall be provided to control leaks of flammable liquids. Fuel oil booster pump found with active leak at o-ring assembly.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 October 2019
Resolved
Accommodation and service spaces and control stations of cargo ships shall be protected by a fixed fire detection and fire alarm system and/or an automatic sprinkler, fire detection and fire alarm system as follows depending on a protection method adopted in accordance with regulation. PSCO discover 07 non-operational smoke detectors in vessel cargo tunnel areas. Fire detection system must be fully functional prior to departure.
74 SOLAS (2014) II-2/7.5.5
17 a,c
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 21 September 2018
Resolved
1730- Oily water separating equipment - 10c
System shall be provided w/arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15ppm.
PSCO observed two of the three air hoses for the three way valve were ruptured, rendering it inoperable.
MARPOL I/14.7
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 20 April 2017
Resolved
0750: Means shall be provided to control leaks of flammable liquids. Sight glass for emergency generator F/O tank is leaking. 74SOLAS(04)II-2/4.1.1
Engineering › Fuel Oil Service System › Piping
Issued 20 April 2017
Resolved
0750. Means shall be provided to control leaks of flammable liquids. Thermal oil pipe for heating heavy F/O tanks is leaking. 74SOLAS(04)II-2/4.1.1
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.