NACC ANTIGUA is a 2012 freight ship. The Coast Guard has recorded 10 inspections since 2016, most recently in September 2023, along with 5 deficiencies and 1 operational control.
Records from 2016 to 2023. Most recent: inspection, 22 September 2023.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it11251 - Convention (Subpart B), Gross Ton 4372 - Convention (Subpart B), Net Ton 17158 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 10
22 September 2023PSC B
Physical examination · Sector Detroit · USCG Great Lakes District (CGD-GL) · Activity 7795375
21 September 2023Administrative Inspection
Administrative · Marine Safety Unit Thousand Islands · USCG Great Lakes District (CGD-GL) · Activity 7796245
27 October 2019Deficiency Check · PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6839862
19 December 2018Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6601370
13 October 2018Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6560803
21 September 2018Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6543276
10 August 2017Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6236037
5 June 2017Deficiency Check
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6166196
14 April 2017PII Safety Exam · ISPS II Exam · Deficiency Check · Ballast Water Examination
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6124444
7 June 2016PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 5900086
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 September 2023Resolved
The purpose of this regulation is to prevent the ignition of combustible materials or flammable liquids. For this purpose, the following functional requirements shall be met: Means shall be provided to control leaks of flammable liquids. Fuel oil booster pump found with active leak at o-ring assembly.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 September 2023
Resolved 22 September 2023
Resolution: USCG verified repair, test of pump witnessed. All found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 October 2019Resolved
Accommodation and service spaces and control stations of cargo ships shall be protected by a fixed fire detection and fire alarm system and/or an automatic sprinkler, fire detection and fire alarm system as follows depending on a protection method adopted in accordance with regulation. PSCO discover 07 non-operational smoke detectors in vessel cargo tunnel areas. Fire detection system must be fully functional prior to departure.
74 SOLAS (2014) II-2/7.5.5
17 a,c
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 28 October 2019
Resolved 28 October 2019
Resolution: Received Class Report attesting to satisfactory repairs.
14 - Pollution Prevention › 141 - MARPOL Annex I › Oil discharge monitoring and control system
Issued 21 September 2018Resolved
1730- Oily water separating equipment - 10c
System shall be provided w/arrangements to ensure that any discharge of oily mixtures is automatically stopped when the oil content of the effluent exceeds 15ppm.
PSCO observed two of the three air hoses for the three way valve were ruptured, rendering it inoperable.
MARPOL I/14.7
Condition: Design Flaw
Action required: 10 - Deficiency Rectified
Due 21 September 2018
Resolved 21 September 2018
Resolution: Hoses were replaced and the valve was tested satisfactory
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 20 April 2017Resolved
0750: Means shall be provided to control leaks of flammable liquids. Sight glass for emergency generator F/O tank is leaking. 74SOLAS(04)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 21 April 2017
Resolution: Received class report attesting to the repairs.
Engineering › Fuel Oil Service System › Piping
Issued 20 April 2017Resolved
0750. Means shall be provided to control leaks of flammable liquids. Thermal oil pipe for heating heavy F/O tanks is leaking. 74SOLAS(04)II-2/4.1.1
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 5 June 2017
Resolution: Received class report attesting to the repairs (attached).
Ownership record