Records from 2014 to 2026. Most recent: inspection, 21 April 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 17
21 April 2026
Deficiency Check · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8354343
26 February 2025
Annual Inspection · Drydock Exam
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8086557
13 February 2024
COI Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7865137
23 February 2023
Annual Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7641125
12 April 2022
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7429525
17 August 2021
Administrative Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7336015
29 April 2021
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7181710
25 February 2021
Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7181678
1 April 2020
Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7005516
6 February 2020
Appeal · Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6904537
14 January 2020
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6889679
25 October 2019
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6841656
28 February 2019
DAPI Audit · Administrative Inspection · Deficiency Check · COI Inspection · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6625511
22 March 2018
Annual Inspection · DAPI Audit · Administrative Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6398657
9 March 2017
Hull Examination · Drydock Exam · Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6104249
2 May 2016
Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5915808
18 March 2014
Administrative Inspection · COI Inspection · In-Service Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 4818625
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 April 2026
Resolved
Need to install drip pan with flame screen under fuel filter. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 21 April 2026
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 January 2020
Resolved
A space containing machinery powered by, or fuel tanks for, gasoline must have a ventilation system that complies with this section. The vessel was found to have an inadequate ventilation system for a vessel containing gasoline independent fuel tanks in an enclosed space.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2020
Resolved 1 April 2020
Resolution: Marine Inspector verified adequate ventilation system installed in the enclosed space.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 14 January 2020
Resolved
A flammable vapor detection system required by 182.410(c) must meet UL 1110 (incorporated by reference; see 46 CFR 175.600) or be approved by an independent laboratory. The installed flammable vapor detection failed the operational test.
Action required: 10 - Deficiency Rectified
Resolved 14 January 2020
Resolution: Vessel removed and replace the vapor detection system in-kind. Operational test was completed successfully.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 28 February 2019
Resolved
Provide a satisfactory baffle leak test on the aft starboard compartment in accordance with Sector Honolulu's work instruction #7.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 5 March 2019
Resolution: Marine Inspector conducted a successful baffle leak test on aft starboard compartment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 28 February 2019
Resolved
Provide a working bilge pump in both manual/automatic modes that produce a visual indicator upon actuation for all installed bilge pumps.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2019
Resolved 5 March 2019
Resolution: Marine Inspector verified bilge pump worked in both automatic/manual modes and verified visual indicator on helm.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 February 2019
Resolved
Replace 06 adult lifejackets that were found to be in un-serviceable condition.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 March 2019
Resolved 28 February 2019
Resolution: Marine Inspector verified the replacement of 06 adult lifejackets.