← All vessels
CHAILEASE CHERISH
CHAILEASE CHERISH is a 2013 freight ship. The Coast Guard has recorded 6 inspections since 2017, most recently in October 2023, along with 7 deficiencies and 1 operational control.
Records from 2017 to 2023. Most recent: inspection, 16 October 2023.
- Built
- 2013
- Last inspected
- 16 October 2023
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 7 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9642502 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
VRML9
1268145
Flag
LIBERIA
—
Maury page id
psix-1268145
Inspections, by type
The 6 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it41684 - Convention (Subpart B), Gross Ton
25928 - Convention (Subpart B), Net Ton
76180 - Dead Weight, Metric Ton
89765 - Displacement, Metric Ton
25928 - Convention (Subpart B), Net Ton
76180 - Dead Weight, Metric Ton
89765 - Displacement, Metric Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 6
16 October 2023
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7809596
13 October 2023
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7804666
28 May 2021
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7201353
10 July 2020
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6992329
30 October 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6566804
30 October 2017
PII Safety Exam · ISPS II Exam · Ballast Water Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 6293401
Deficiency record · 7
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 13 October 2023
Resolved
The electrical power available shall be sufficient to supply all those services that are essential for safety in an emergency. PSC observed lube oil pressure alarm upon start up of emergency diesel generator. 74 SOLAS (20) II-I/43.2, Restricted,Rectify deficiency prior to departure, Code 17
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 13 October 2023
Resolved
A fixed fire extinguighing system required by paragraph 5 below may be any of the following systems: A fixed gas fire extinguishing system complying with the provisions of the fire safety systems code. The piping and associated equipment shall be adequately supported. 74 SOLAS (20), II-II/4.1.1.1, Rectify deficiencies prior to next U.S. port after sailing foreign, Code 40
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 July 2020
Resolved
07199- Oil fuel pipes fitted with valve directly on tank shall be capable of being closed from outside the space. Found quick-closing valve on stbd HFO tank incapable of being closed.
Site: 74 SOLAS(14) II-2/4.2.2.3.4
07 - Fire Safety › N/A - No Subsystem › Operation of Fire protection systems
Issued 10 July 2020
Resolved
07123-Fire Protection systems and fire-fighting systems and appliances shall be maintained ready for use. Water mist system above #1 generator is inoperable in automatic mode.
Site: 74 SOLAS (14)II-2/14.1.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 10 July 2020
Resolved
13108-Machinery and associated piping and fittings shall be adequate for intended service and installed as to reduce dangers. #2 Generator is leaking exhaust and oil from turbo. Site: 74 SOLAS(14) II-I/26.1
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 10 July 2020
Resolved
07124 – Maintenance, testing, and inspections shall be carried out having due regard to ensure reliability of firefighting systems and appliances. Crew did not test flame detector in accordance with manufacturer's testing instructions.
Site: 74 SOLAS(14) II-2/14.2.2.1
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 July 2020
Resolved
13199 – The condition of the ship and its equipment shall be maintained to ensure that the ship will remain fit to proceed to sea without danger to the ship or persons onboard. The outboard air start tank relief valve has excessive pitting in its body.
Site: 74 SOLAS (14) I/II(a)
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.