This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Tonnage as PSIX records it34422 - Convention (Subpart B), Gross Ton 19571 - Convention (Subpart B), Net Ton 58450 - Dead Weight, Ton 69920 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 20 March 2022Resolved
The function of fixed fire detection and fire alarm systems shall be periodically tested to the satisfaction on the administration by means of equipment producing hot air at the appropriate temperatures, or smoke or aerosol particles having the appropriate range of density or particle size, or other phenomena associated with incipient fires to which the detector is designed to respond.
PSCO observed VSL's crew attempting to use lighter to test flame detector in engine room during Port State exam; Expanded exam to look at SMS, which required use of strong flashlight for which none was onboard. VSL crew stated "such flashlight was ordered yesterday" after being required during Flag State inspection. Vessel must acquire the proper testing equipment for flame detectors as is required by SMS and all flame detectors in engine room must be tested and functioning properly to the satisfaction of Class.
74SOLAS(20)II-2/7.3.2; 17ac
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Resolved 26 March 2022
Resolution: Verified onboard on 26 MAR 2022 that the vessel received flame detector test lamp of maker SENSE-WARE, model TC-229/4P, serial number 2221113. The operation of the flame detector test lamp and the activation of flame type fire detectors in the engine room