MAURY USCG vessel records Sign in
← All vessels

EMS 407P

EMS 407P is a 2015 tank barge. The Coast Guard has recorded 9 inspections since 2015, most recently in September 2025, along with 1 deficiency.

Records from 2015 to 2025. Most recent: inspection, 2 September 2025.

Built
2015
Last inspected
2 September 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

1268939
Flag
UNITED STATES
—
Maury page id
psix-1268939

Inspections, by type

Years with a record 7 calendar years (2015–2025)
The 9 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Documentation record

Registered dimensions (L × B × D)262.0 ft × 48.0 ft × 12.0 ft
Registered tonnagegross 1,267 / net 1,267
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSNEED SHIPBUILDING INC · Channelview, TX, UNITED STATES · built 2015
Hull materialSteel
PropulsionNot recorded
Hull shapeBox
Hull configurationMonohull
Hailing portHOUMA, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 23 June 2026 · expires 31 July 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1267 - Simplified, Gross Ton
1267 - Simplified, Net Ton
1343 - Displacement, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 9

2 September 2025 In-Service Inspection · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 8225184
8 August 2025 COI Inspection · Drydock Exam · MTSA Verification · Internal Structural Exam · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8202983
10 October 2023 Examination of Repairs · Internal Structural Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7805901
14 September 2020 COI Inspection · Internal Structural Exam · In-Service Inspection · Administrative Inspection · MTSA Verification
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 7057832
11 September 2018 DAPI Audit · Periodic Inspection · MTSA Verification · COI Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6537700
20 December 2017 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6336334
3 December 2016 Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 6066540
1 September 2015 Initial Certification · Initial Construction-Excluding Oversight · MTSA Verification · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5232520
14 July 2015 Administrative Inspection · Construction Oversight
Physical examination · Marine Safety Unit Morgan City · USCG Heartland District (CGD-H) · Activity 5184425

Deficiency record · 1

03 - Water/Weathertight Conditions › N/A - No Subsystem › Cargo & other hatchways
Issued 10 October 2023 Resolved
Scantlings, material, and workmanship, subdivision of cargo spaces, fitting of cofferdams, and testing of tanks shall be at least equivalent to the requirements of the American Bureau of Shipping or other recognized classification society. MI observed seven (07) broken welds on side shell longitudinals inside port wing voids #3, #4, #5 and #7. MI observed gasket on forward portion of hopper rain shield to be wasted, preventing weather tight seal. MI observed damaged and insufficient packing on cargo tank saddle in starboard wing void #4. Vessel is to enact permanent repairs to the satisfaction of a Marine Inspector prior to departure. 46 CFR 32.60-1(a)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 October 2023
Resolution: Vessel renewed all broken welds, installed new gasket, and used spray foam to repair saddle.

Ownership record