← All vessels
MAUD
Freight Ship · Bulk Carrier class · Built 2010s · USCG Northwest District (CGD-NW) · Other hulls named MAUD
MAUD is a 2012 freight ship. The Coast Guard has recorded 10 inspections since 2016, most recently in October 2025, along with 6 deficiencies and 3 operational controls.
Records from 2016 to 2025. Most recent: inspection, 1 October 2025.
- Built
- 2012
- Last inspected
- 1 October 2025
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 6 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9551674 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
9V8893
1269215
Flag
SINGAPORE
—
Maury page id
psix-1269215
Inspections, by type
…with no type recorded2
Years with a record
4 calendar years (2016–2025)
The 10 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.
Documentation record
Tonnage as PSIX records it32987 - Convention (Subpart B), Gross Ton
56895 - Dead Weight, Metric Ton
67681 - Displacement, Metric Ton
19238 - Convention (Subpart B), Net Ton
56895 - Dead Weight, Metric Ton
67681 - Displacement, Metric Ton
19238 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 10
1 October 2025
Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8234816
15 September 2023
PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7791979
19 July 2022
Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7511269
7 April 2022
Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7426672
9 March 2022
PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7401275
7 March 2022
Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7407400
16 February 2022
PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7392066
9 February 2022
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7393382
7 February 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7392077
30 March 2016
Ballast Water Examination · ISPS II Exam · PII Safety Exam
Physical examination · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 5843424
Deficiency record · 6
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 February 2022
Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling, or daily service tank having a capacity of 500 L and above situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. PSCO observed quick closing valve for LSMGO service tank, which was currently in use, intentionally blocked open with sockets which prevented the valve from being closed from outside the space during an emergency and was unable to confirm proper operation of the valve. 74SOLAS (2009 Cons.) II-2/4.2.2.3.4
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 16 February 2022
Resolved
The company should identify equipment and technical systems the sudden operational failure of which may result in hazardous situations. The safety management system should provide for specific measures aimed at promoting the reliability of such equipment or systems. As noted in deficiency 01, PSCO observed the quick closing valve for the LSMGO service tank blocked open. The [name withheld] stated that the valve had been blocked open a week earlier during routine testing to prevent inadvertent shut down of running machinery. Chief Engineer stated he was unaware of valve blockage. The vessel was unable to provide any procedures for testing quick closing valves or safety guidance prohibiting quick closing valve blocks. 74 SOLAS (2020 cons.) IX/3.1, ISM 10.3
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 16 February 2022
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. PSCO observed 02 2-inch holes above the cable room door located on the A deck. 74SOLAS(2009) II-2/14.2.1.1.1
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 16 February 2022
Resolved
Guard rails fitted on superstructure and freeboard decks shall have at least three courses, the opening below the lowest course of the guard rails shall not exceed 230 mm. PSCO observed guard rail located on starboard side of cargo hold #2 with bottom course missing. ICLL 66/88 Annex I/Reg 25(3)
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 February 2022
Resolved
Suitable instructions and component spares for testing and maintenance shall be provided. Detectors shall be periodically tested using equipment suitable for the types of fires to which the detector is designed to respond. PSCO observed flame detector testing light inoperable. Crew was able to find spare battery and tested flame detector satisfactorily. 74 SOLAS (2009 Cons.) II-2/7.2.2.2, FSS Code 9.2.5.2
Fire Fighting › Miscellaneous Items › Electric Radiators
Issued 4 April 2016
Resolved
01 0710 Electric radiators shall be fixed and so constructed as to reduce fire risk to a minimum. Vessel used a shelf above the radiator in the steering gear room to store flammable fuel samples. 74 SOLAS (04 Cons.) II-2/4.4.1 10c Corrected on the spot.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.