MAUD is a 2012 freight ship. The Coast Guard has recorded 10 inspections since 2016, most recently in October 2025, along with 6 deficiencies and 3 operational controls.
Records from 2016 to 2025. Most recent: inspection, 1 October 2025.
Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
The counts in the strip above are the same counts; this table splits the inspections by
the kind of activity recorded. A blank resolution means none was recorded in this data; it
does not establish that a deficiency is outstanding. Years with a record are calendar
years in which a record exists, not years in service.
What Maury does not do.
Documentation record
Tonnage as PSIX records it32987 - Convention (Subpart B), Gross Ton 56895 - Dead Weight, Metric Ton 67681 - Displacement, Metric Ton 19238 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299
What it gives that this page does not: the whole record in one
dated, citable document — every line with its Coast Guard activity id, the retrieval
date on the cover, built to print to PDF with its page breaks — that a surveyor can
attach and a lender can file. The same facts as this page, complete and in one file.
Every recorded inspection, 2016 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
A request, not a checkout: leave an email and Maury replies once, with
the dated document for this hull and a Stripe invoice for $299. Nothing is charged before
the document is in your hands.
Used only to answer this request.
Not shared, not sold, and not added to a mailing list.
Inspection history · 10
1 October 2025Administrative Inspection
Administrative · Sector Columbia River · USCG Northwest District (CGD-NW) · Activity 8234816
15 September 2023PSC B
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 7791979
19 July 2022Administrative Inspection
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7511269
7 April 2022Type not recorded
No type recorded · Sector Virginia · USCG East District (CGD-E) · Activity 7426672
9 March 2022PSC B
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7401275
7 March 2022Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7407400
16 February 2022PSC B
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7392066
9 February 2022Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7393382
7 February 2022Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7392077
30 March 2016Ballast Water Examination · ISPS II Exam · PII Safety Exam
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 February 2022Resolved
Oil fuel pipes, which, if damaged, would allow oil to escape from a storage, settling, or daily service tank having a capacity of 500 L and above situated above the double bottom, shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position outside the space concerned in the event of a fire occurring in the space in which such tanks are situated. PSCO observed quick closing valve for LSMGO service tank, which was currently in use, intentionally blocked open with sockets which prevented the valve from being closed from outside the space during an emergency and was unable to confirm proper operation of the valve. 74SOLAS (2009 Cons.) II-2/4.2.2.3.4
Condition: Placed in Improper Service
Action required: 30 - Ship detained
Resolved 18 February 2022
Resolution: DNV Class report submitted showing all quick closing valves operate correctly
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Maintenance of the ship and equipment
Issued 16 February 2022Resolved
The company should identify equipment and technical systems the sudden operational failure of which may result in hazardous situations. The safety management system should provide for specific measures aimed at promoting the reliability of such equipment or systems. As noted in deficiency 01, PSCO observed the quick closing valve for the LSMGO service tank blocked open. The [name withheld] stated that the valve had been blocked open a week earlier during routine testing to prevent inadvertent shut down of running machinery. Chief Engineer stated he was unaware of valve blockage. The vessel was unable to provide any procedures for testing quick closing valves or safety guidance prohibiting quick closing valve blocks. 74 SOLAS (2020 cons.) IX/3.1, ISM 10.3
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 February 2022
Resolution: Class report and company SMS document state traning was conducted on quick closing valve safety and signs posted stating to not block quick closing valves.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 16 February 2022Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if fire occurs: structural fire protection, including fire-resisting divisions, and protection of openings and penetrations in these divisions. PSCO observed 02 2-inch holes above the cable room door located on the A deck. 74SOLAS(2009) II-2/14.2.1.1.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2022
Resolved 7 March 2022
Resolution: See class report attached to act 7407400. Divisions repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 16 February 2022Resolved
Guard rails fitted on superstructure and freeboard decks shall have at least three courses, the opening below the lowest course of the guard rails shall not exceed 230 mm. PSCO observed guard rail located on starboard side of cargo hold #2 with bottom course missing. ICLL 66/88 Annex I/Reg 25(3)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 16 March 2022
Resolved 7 March 2022
Resolution: See class report attached to act 7407400. Rails repaired.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 16 February 2022Resolved
Suitable instructions and component spares for testing and maintenance shall be provided. Detectors shall be periodically tested using equipment suitable for the types of fires to which the detector is designed to respond. PSCO observed flame detector testing light inoperable. Crew was able to find spare battery and tested flame detector satisfactorily. 74 SOLAS (2009 Cons.) II-2/7.2.2.2, FSS Code 9.2.5.2
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 16 February 2022
Resolution: Crew was able to find spare battery and tested flame detector satisfactorily.
Fire Fighting › Miscellaneous Items › Electric Radiators
Issued 4 April 2016Resolved
01 0710 Electric radiators shall be fixed and so constructed as to reduce fire risk to a minimum. Vessel used a shelf above the radiator in the steering gear room to store flammable fuel samples. 74 SOLAS (04 Cons.) II-2/4.4.1 10c Corrected on the spot.
Condition: Placed in Improper Service
Due 4 April 2016
Resolved 4 April 2016
Resolution: Engineers moved fuel samples to the ECR.