Records from 2016 to 2026. Most recent: inspection, 27 January 2026.
Documentation record
Registered dimensions (L × B × D)34.0 ft × 11.0 ft × 3.2 ft
Registered tonnagegross 5 / net 5
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderARMSTRONG MARINE INC · PORT ANGELES, WA, UNITED STATES · built 2014
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeShip
Hull configurationTwin Hull
Hailing portKONA, HI
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 24 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it5 - Simplified, Gross Ton
5 - Simplified, Net Ton
6 - Displacement, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 16
27 January 2026
Deficiency Check · Drydock Exam · Internal Structural Exam · Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8303166
12 March 2025
Annual Inspection
Physical examination · OP location-Sector Honolulu Prevention Department- Kailua Kona · USCG Oceania District (CGD-O) · Activity 8092838
31 January 2024
COI Inspection · DAPI Audit · Internal Structural Exam · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7858318
28 March 2023
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7657990
14 November 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7593741
13 November 2022
Type not recorded
No type recorded · Maritime Safety & Security Team Honolulu (91107) · Activity 7597471
8 March 2022
Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7408072
27 January 2022
Deficiency Check · Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7386617
24 May 2021
Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7205485
21 January 2020
Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7316719
16 January 2020
Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6891217
15 January 2020
DAPI Audit · Drydock Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6890333
25 February 2019
Deficiency Check · COI Inspection · DAPI Audit · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6631950
18 January 2018
DAPI Audit · Hull Examination · Administrative Inspection · Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6339998
30 March 2017
Hull Examination · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6112432
31 January 2016
Administrative Inspection · DAPI Audit · Annual Inspection · Hull Examination
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5834875
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 27 January 2026
Resolved
It was determined that vessel is required to have the following portable extinguishers:
-One (01) 10 B:C extinguisher at operating station
-One (01) 40 B:C extinguisher for outboards
Vessel had one (02) 10 B:C extinguishers at time of inspection and must add one (01) 40 B:C extinguisher. Corrected on the Spot.
Action required: 10 - Deficiency Rectified
Resolved 27 January 2026
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 14 November 2022
Resolved
An MMC, license, MMD, COR, or STCW endorsement must be retained by the mariner to whom it was issued and, while valid, must be produced to verify qualifications when requested by an authorized official as identified in 33 CFR 101.515(d). Posting of the officer endorsement may be necessary as required in 46 U.S.C. 7110. Master of the vessel did not have in possession a MMMC while operating as a master on a certificated vessel.
Action required: 10 - Deficiency Rectified
Due 14 November 2022
Resolved 14 November 2022
Resolution: verified valid MMC
14 - Pollution Prevention › 144 - MARPOL Annex IV (Not Applicable to PSC Exams conducted in the U.S.) › Sewage discharge connection
Issued 14 November 2022
Resolved
When operating a vessel on a body of water where the discharge of treated or untreated sewage is prohibited the operator must secure each type I or type II device in a manner to prevent discharge of untreated or treated sewage. Vessel's overboard sewage discharge line was not secured by acceptable methods.
Master secured overboard sewage discharge in the closed position. Cleared on the spot.
Action required: 10 - Deficiency Rectified
Due 14 November 2022
Resolved 14 November 2022
Resolution: secured valve with acceptable means
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 8 March 2022
Resolved
All vessels must have operable navigation lights in accordance with the Navigation Rules. No stern light. All around mast head is blocked by the post not meeting the stern light requirement. Provide navigation lights that are in compliance with the Navigation Rules.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2022
Resolved 16 March 2022
Resolution: Stern light installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 8 March 2022
Resolved
Fuses in electrical systems must be of the cartridge type only. Fuses for the bilge water alarm are blade type fuses. Provide proper installation of cartridge type fuses in the electrical system onboard the vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 March 2022
Resolved 16 March 2022
Resolution: Cartridge type fuse installed.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 March 2022
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 April 2022
Resolved 7 April 2022
Resolution: Oxygen bottle onboard.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 27 January 2022
Resolved
a vessel must comply with the structural design requirements of one of the standards for the hull material of the vessel. Port hull, center line fwd inboard bottom hull longitudinal stiffener has toe fracture connecting to fwd bulkhead. This deficiency shall be corrected by no later than 21 February 2022.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 21 February 2022
Resolved 22 February 2022
Resolution: Toe fractures grounded smooth and repaired.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 May 2021
Resolved
Portable fire extinguishers must be inspected and maintained in accordance with NFPA 10. The vessel could not provide proof of annual servicing. Provide proof of annual servicing or schedule third party servicing within the deficiency due date.
46 CFR 176.810(b)(1)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 June 2021
Resolved 10 June 2021
Resolution: New fire extinguishers purchased.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 15 January 2020
Resolved
The EPIRB's battery is replaced after it is used, or before the date required by FCC regulations in 47 CFR part 80, whichever comes sooner. Found the EPIRB's battery to have expired on 08/2019.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 January 2020
Resolution: Replaced EPIRB battery.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 January 2020
Resolved
Each item of lifesaving equipment determined by the marine inspector to not be in serviceable condition must be repaired or replaced. Found 07 adult lifejacket with holes and other deteriorations. Passenger count reduced by 07.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2020
Resolved 21 January 2020
Resolution: Replaced 07 lifejackets.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 15 January 2020
Resolved
Each life jacket must be marked with Type I retroreflective material approved in 46 CFR 164.018. Found 03 adult lifejackets and 06 child lifejackets with nonfunctional retroreflective material.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2020
Resolved 21 January 2020
Resolution: Replced retro tape 09 lifejackets.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 15 January 2020
Resolved
Portable fire extinguishers must be located so that they are clearly visible and readily accessible from the space being protected. The installation and location must be to the satisfaction of the Officer in Charge, Marine Inspection. The forward and aft port portable fire extinguisher mounting system does not allow for quick and easy access.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2020
Resolved 21 January 2020
Resolution: Replaced firw extinguisher's mount.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 15 January 2020
Resolved
The name of a vessel must be marked or painted in clearly legible letters and numbers on each life float and buoyant apparatus. The forward life ring does not have the vessel's name printed on it.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 January 2020
Resolved 21 January 2020
Resolution: Printed name on fwd life ring.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 25 February 2019
Resolved
Provide a working audible alarm for the port & starboard high level alarm for the bilge system.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2019
Resolved 20 March 2019
Resolution: Marine Inspector verified audible alarm for port/starboard high level alarm for the bilge system.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 25 February 2019
Resolved
Provide proof of the vessel having a valid FCC radio safety certificate.
47CFR13
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2019
Resolved 20 March 2019
Resolution: Marine Inspector verified vessel's FCC radio safety certificate
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 25 February 2019
Resolved
Provide proof of having all required medicines within expiration dates for the vessel's first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 25 March 2019
Resolved 20 March 2019
Resolution: Marine Inspector verified vessel having all proper medicines within first aid kit.