Records from 2016 to 2025. Most recent: operational control imposed, 23 July 2025.
Inspection history · 17
22 July 2025
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 8191936
2 July 2024
Drydock Exam · Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7947087
1 March 2024
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7872841
22 August 2023
Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7774033
1 February 2023
Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7630564
14 September 2022
In-Service Inspection · DAPI Audit · Administrative Inspection · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7558930
16 November 2021
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7356495
3 November 2021
Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7344459
16 October 2020
Annual Inspection · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7080218
26 August 2020
Hull Examination · Examination of Repairs
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 7054259
28 August 2019
Annual Inspection · DAPI Audit · Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6798938
5 November 2018
COI Inspection · DAPI Audit · Hull Examination
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6574529
20 February 2018
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6358017
7 November 2017
Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6302484
17 January 2017
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 6072140
3 February 2016
Deficiency Check
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5808826
14 January 2016
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Port Canaveral · USCG Southeast District (CGD-SE) · Activity 5798130
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 July 2025
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Replaced wasted life jackets with CG approved life jackets 2 child, 5 adults. Reduced passengers by 5.
46CFR180.71 (a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 August 2025
Resolved 6 August 2025
Resolution: Received photo evidence of new life jackets.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 July 2025
Resolved
If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches). Attach remote device to fuel valve to prevent crew from reaching bellow engine to secure valve.
46CFR182.455 (b) (4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2025
Resolved 6 August 2025
Resolution: Received photo evidence of cable instalation.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 March 2024
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 705 - Other - as specified
Resolved 11 March 2024
Resolution: New COI issued.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 August 2023
Resolved
Each person onboard shall be provided with a type I PFD. Eleven adult type I PFD's were not suitable for service.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 August 2023
Resolved 24 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 August 2023
Resolved
Life ring buoys shall be available and ready for service. The retro-reflective tape was worn excessively and the water-light was extinguished.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 August 2023
Resolved 24 August 2023
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 24 August 2023
Resolved
Navigation lights shall be fitted in accordance with the COLREGS. The port and starboard navigation lights were found extinguished.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 24 August 2023
Resolved 24 August 2023
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 21 September 2022
Resolved
Marine employers shall establish programs for the chemical testing for dangerous drugs on a random basis of crewmembers on inspected vessels. Complete satisfactory DAPI Audit.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 October 2022
Resolved 26 January 2023
Resolution: DAPI Audit Complete
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 14 September 2022
Resolved
A vessel must be provided with a main steering gear that is: Of adequate strength and capable of steering the vessel at all service speeds. Repair fracture on air rudder support.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 2 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 September 2022
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. Mark vessel name on ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 2 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 September 2022
Resolved
Each ring life buoy must be marked with Type II retroreflective material. Replace retroreflective material on ring buoy.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 2 December 2022
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 14 September 2022
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Clean all lifejackets.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 2 December 2022
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 September 2022
Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. Replace expired contents of first aid kit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 2 December 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 14 September 2022
Resolved
Where flexible nonmetallic hose is permitted for use in piping systems by this section, it must meet SAE J-1942. Replace cracked fuel tank vent hose and fuel hose to fuel filter.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 2 December 2022
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 September 2022
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil, trash, debris, or other matter that might create a fire hazard, clog bilge pumping systems, or block emergency escapes. Clean bilges.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 2 December 2022
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 14 September 2022
Resolved
If posting is impracticable, such as in an open boat, the certificates must be kept on board in a weathertight container readily available for use by the crew and display to passengers and others on request. Replace all illegible certificates, documents, and plans.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 October 2022
Resolved 2 December 2022
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 3 November 2021
Resolved
A vessel must be provided with a main steering gear that is: Of adequate strength and capable of steering the vessel at all service speeds. Replace cracked bushings on top and bottom of port air rudder.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 November 2021
Resolved 16 November 2021
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 26 August 2020
Resolved
Vee areas along the chine with visible porosity and apply new weld bead along both chines.
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2020
Resolved 16 October 2020
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 26 August 2020
Resolved
Vee and weld crack on side shell at 3rd row seat port side.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2020
Resolved 16 October 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 August 2020
Resolved
Provide access to fuel shutoff or provide remote closing device.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2020
Resolved 16 October 2020
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 26 August 2020
Resolved
Install guard for rotating machinery IWO steering station.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2020
Resolved 16 October 2020
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 26 August 2020
Resolved
Remove additional wiring or provide plan for acceptance.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2020
Resolved 16 October 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 26 August 2020
Resolved
Renew fuel vent hose.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 26 September 2020
Resolved 16 October 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 26 August 2020
Resolved
Provide three adult PFD's to replace condemed PFD's.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 26 September 2020
Resolved 16 October 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 28 August 2019
Resolved
Renew lower bushing on starboard rudder where cracked.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2019
Resolved 20 September 2019
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 28 August 2019
Resolved
Install 3-6 foot lanyard on water light with corrosion resistant clip.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2019
Resolved 20 September 2019
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 28 August 2019
Resolved
Renew FL numbers on starboars side where worn off.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 28 September 2019
Resolved 20 September 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 November 2018
Resolved
Renew port side bilge pump.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2018
Resolved 20 September 2019
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 6 November 2018
Resolved
Properly repair fracture in port side shell plate and port side forward bottom frame.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 November 2018
Resolved 20 September 2019
Construction/Loadline › Hull › Hull Plating
Issued 7 November 2017
Resolved
Renew securing brackets for 3rd row seat and vee and weld side-shell fractures on port and starboard side.
Condition: Damaged By Earlier Event
Due 7 December 2017
Resolved 1 December 2017
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 7 November 2017
Resolved
Provide six adult size PFD's. Passenger count reduced to nine until provided.
Condition: Improper/Lack of Maintenance
Due 7 December 2017
Resolved 1 December 2017
Construction/Loadline › Hull › Hull Plating
Issued 7 November 2017
Resolved
Crop and renew starboard side transom where fractured NLT 18".
Condition: Damaged By Earlier Event
Due 7 December 2017
Resolved 1 December 2017
Engineering › Bilge Water Management System › Pump
Issued 7 November 2017
Resolved
Provide new bilge pump.
Condition: Damaged By Earlier Event
Due 7 December 2017
Resolved 1 December 2017
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 17 January 2017
Resolved
Provide serviceable battery for water-light.
Condition: Improper/Lack of Maintenance
Due 24 January 2017
Resolved 26 January 2017
Engineering › Bilge Water Management System › Pump
Issued 17 January 2017
Resolved
Provide 5GPM portable bilge pump.
Condition: Improper/Lack of Maintenance
Due 24 January 2017
Resolved 26 January 2017
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 14 January 2016
Resolved
Renew reflective tape on life ring
Due 14 February 2016
Resolved 3 February 2016
Resolution: New reflective tape has been installed.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 14 January 2016
Resolved
Renew batteries in waterlight. Prior to the carriage of passengers at night.
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2016
Resolved 5 February 2016
Resolution: Received reciept and photo of new water light battery.