Records from 2016 to 2025. Most recent: inspection, 16 December 2025.
Documentation record
Registered dimensions (L × B × D)92.7 ft × 32.0 ft × 6.9 ft
Registered tonnagegross 93 / net 63
ITC dimensions (L × B × D)92.7 ft × 32.0 ft × 6.9 ft
ITC tonnagegross 209 / net 94
BuilderSHIPBUILDERS OF WI INC · MANITOWOC, WI, UNITED STATES · built 2014
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 29 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it209 - Convention (Subpart B), Gross Ton
93 - Regulatory (Subpart C or D), Gross Ton
94 - Convention (Subpart B), Net Ton
63 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 25
16 December 2025
Plan Review (Other than "T")
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8286344
16 July 2025
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8187261
10 March 2025
MTSA/ISPS Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8090922
11 February 2025
Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8081935
12 March 2024
COI Inspection · MTSA Verification · DAPI Audit
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7875727
24 May 2023
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7695409
17 May 2022
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7452730
27 April 2022
Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7439060
15 October 2021
Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 7334709
26 April 2021
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7183639
14 April 2021
Annual Inspection · DAPI Audit · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7176558
11 March 2020
MTSA Verification · DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6924731
18 September 2019
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6815264
18 April 2019
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6667918
15 April 2019
DAPI Audit · Administrative Inspection · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6663106
4 October 2018
Examination of Repairs · Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6563095
12 June 2018
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6444304
23 May 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6421723
11 April 2018
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6387703
10 April 2018
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6389067
30 March 2017
DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6289101
2 March 2017
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6097987
6 February 2017
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6083435
28 April 2016
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5864401
31 March 2016
DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5847209
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 14 April 2021
Resolved
Fire detection panel has not been serviced. Perform annual service on fire detection panel and provide report to OCMI prior to carriage of passengers.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 16 April 2021
Resolution: Fire Detection Panel was serviced and report submitted.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 14 April 2021
Resolved
Top deck port side life ring needs type II retroreflective material for missing section. Replace missing retrofeflective tape.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 14 April 2021
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 14 April 2021
Resolved
Cable in port side of HAVC space in overhead is not metal supported at least every 24" and where cable penetrates through forward WTB is not sealed. Support cable at least every 24" and seal cable through WTB penetrate block.
Action required: 10 - Deficiency Rectified
Resolved 14 April 2021
Resolution: Cable has been supplied with metal suports at least every 24" and penetrate block has been sealed to the satisfaction of Marine Inspector.
05 - Radio Communications › N/A - No Subsystem › SART/AIS-SART
Issued 17 April 2019
Resolved
AIS is transmitting incorrect info. AIS must be programmed to match FCC and COD. 33 CFR 164.46
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2019
Resolved 30 August 2019
Resolution: reprogrammed AIS
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 April 2019
Resolved
Air compressor tank in engineroom does not have the ASME stamp "U" or "UM" as required. Replace tank with ASME approved tank. 46 CFR 54.01-5
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2019
Resolved 30 August 2019
Resolution: Installed new ASME approved tank
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 17 April 2019
Resolved
2 Life rings FWD main deck and upper deck STBD side life lines are dry rotted anf fraying. Replace life lines on both life rings. 46 CFR 117.70
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2019
Resolved 30 August 2019
Resolution: replaced lines
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 17 April 2019
Resolved
Electrical cables for firepump and bilge pump need to be supported with metal clamps every 24 inches. 46 CFR 120.340
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 May 2019
Resolved 30 August 2019
Resolution: Installed metal clamps as required
Engineering › Engine Controls (Electric/Electronic) › Actuator
Issued 31 March 2016
Resolved
Conduct Periodic Safety Test Procedures IAW 46 CFR 121.620(d)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2016
Resolved 27 April 2016