Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
Registered dimensions (L × B × D)297.5 ft × 54.0 ft × 12.0 ft
Registered tonnagegross 1,619 / net 1,619
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTRES PALACIOS MARINE LP · PALACIOS, TX, UNITED STATES · built 2014
Hull materialSteel
PropulsionUNSPECIFIED
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 9 July 2026 · expires 31 August 2027
Service, as the file records itTank Barge
Hull formbarge (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it1619 - Simplified, Gross Ton 1619 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026 for this class, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 14
23 January 2026MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Port Arthur · USCG Heartland District (CGD-H) · Activity 8299965
15 October 2024Examination of Repairs · Drydock Exam · Internal Structural Exam · COI Inspection · Cargo Tank Internal
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8019368
6 September 2023Administrative Inspection · Annual Inspection · Examination of Repairs
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 January 2022
Resolved 14 January 2022
Resolution: Vessel rep provided evidence of original COI on barge.
A 2 foot wide by 4 inch deep inset was found at the port side #5 wing void. Inset caused separation of lap weld at the deck gunwale, compromising watertight integrity. Effect permanent hull repair prior to loading cargo. 46 CFR 32.60-1
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2018
Resolved 31 October 2018
Resolution: Marine Inspector attended vessel to inspect proper hull repair.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 29 October 2018Resolved
Pull cable for prime mover emergency shutdown failed, breaking near the pull handle, while testing emergency shutdown system. Repair or replace cable and test for satisfactory system shutdown prior to loading cargo. 46 CFR 32.50-35
Condition: Design Flaw
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2018
Resolved 31 October 2018
Resolution: Marine Inspector attended vessel to inspect newly installed emergency shutdown pull cable.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 October 2018Resolved
Equipment not available to test cargo high/overfill alarms. Prove proper operation of alarms prior to loading cargo. 46 CFR 39.2009(a)(2)(iv)
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2018
Resolved 31 October 2018
Resolution: Marine Inspector witnessed satisfactory test of the vessel's high/overfill liquid level alarms.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 29 October 2018Resolved
Vapor control piping not available for inspection. Provide letter, IAW D8 Policy Letter 01-2017, that attest vapor cargoes have not been carried onboard since vessel's last annual inspection. 46 CFR 39.2014(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2018
Resolved 31 October 2018
Resolution: Marine Inspector attended vessel and inspected inside of vapor header.
09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 29 October 2018Resolved
Certain cargo tank hatches had faded warning statements. Stencil or placard "Danger Keep Out" warning statement on cargo tank hatches. 46 CFR 35.05-15(b)(3)(ii)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 November 2018
Resolved 31 October 2018
Resolution: Marine Inspector attended vessel and inspected repainted cargo tank hatch covers.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Cargo transfer - Tankers
Issued 29 October 2018Resolved
Cargo transfer hose had no product marking and was marked with test pressure. Remove test pressure from cargo hose. Mark cargo hose appropriately for cargo being transfered or "Oil Service" for oil products, and with the maximum allowable working pressure. 33 CFR 155.800
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 October 2018
Resolved 31 October 2018
Resolution: Marine Inspector attended vessel and inspected cargo hose identification band with product name and MAWP.
P/V Relief Valve not properly set to required (Toxic Cargo) Pressure Setting of not less than 3.0 PSI. Currently the Pressure Setting is at 2.5 PSI.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Resolved 21 September 2015
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National